Skip to main content
toggle menu
Home
User account menu
  • Products
  • Stockists
  • White Book Specification Selector
  • Log in / Register
Main navigation
  • Inspiration
    Building Better
    • Building Better Hub
    • Project Showcase
    Learn more
    Saint-Gobain Solutions Centre
    Learn more
  • Specification
    White Book Specification Selector
    • White Book Overview
    • Ceilings
    • External Walls
    • Floors
    • Horizontal ShaftWall
    • Internal Partitions & Walls
    • Shaftwall
    • Steel Protection
    • Thistle Plaster Systems
    • Timber Frame
      Display in two columns
      Off
    • Wall Linings
    • BS Specifications
      Display in two columns
      Off
    Learn more
    Our Products
    • Acoustic ceiling systems
    • British Gypsum fixings
    • Gypframe
    • Gyproc Firestopping
      Display in two columns
      Off
    • Gyproc jointing products
    • Gyproc plasterboards
    • Thistle plasters
    Learn more
    Resources and Literature
    • All literature
    • Declaration of Performance
    • Design Guidance
    • Environmental Product Declarations
    • Product Data Sheets
    • Safety Data Sheets
    Learn more
    SpecSure® System Warranty
    Learn more
  • Installation
    Our Products
    • Acoustic ceiling systems
    • British Gypsum fixings
    • Gypframe
    • Gyproc Firestopping
      Display in two columns
      Off
    • Gyproc jointing products
    • Gyproc plasterboards
    • Thistle plasters
    Learn more
    The Plasterer’s Hub
    • Join the Certified Plasterer Scheme
    • Find a Certified Plasterer
    Learn more
    Installation Guidance and Support
    • Installation Guides
    • Product, project and training support
    Learn more
    Stockist Locator
    Learn more
  • Skills Development
    Upskilling Courses
    • Book a course
    • Site Ready Skimming Course
      Display in two columns
      Off
      Background color
      Grey
    • Training Prospectus
      Display in two columns
      Off
      Background color
      Grey
    • Training Academies
    Learn more
    Students, Apprentices and New Trainees
    • Partnership Colleges
    Learn more
    E-Learning
    • Our Platform and Courses
    Learn more
    CPD Resource
    • Acoustic Design
      Display in two columns
      Off
    • Inhibiting Fire Growth
    • System Integrity
      Display in two columns
      Off
    Learn more
  • Technical Support
    Self Help Tools
    • FAQs
    • Plaster Coverage Calculator
    • Thermal Calculator
    • Design Guidance
    • Fire-Rated Junctions Guide
      Display in two columns
      Off
    • Resources and Literature
    Learn more
    Technical Consultancy
    • Technical Enquiry Form
    Learn more
    SpecSure® System Warranty
    Learn more
  • Customer Services
    Services
    • Distribution Innovation
    • Track and Trace
    Learn more
Breadcrumb
  1. Home
  2. Specification
  3. White Book Specification Selector
  4. External Walls
  5. GypLyner Xternal
  6. T106037 (EN)
Help menu
Last reviewed:
02.12.2024
Last updated:
17.06.2025
Image
Image
Share
Email Facebook Twitter Linkedin
Print
Bookmark this page
Download
GypLyner Xternal

T106037 (EN)

A non-loadbearing external wall construction including a 20mm deflection head with one layer of Glasroc X Sheathing Board 12.5mm to external side and two layers of Gyproc SoundBloc 15mm to the internal side of 100mm Intrastack SFS framework. 50mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 4000mm.

Read more
Read less
Fire Integrity (mins)
90
Fire Insulation (mins)
90
Sound Insulation (Airborne) Rw (dB)
49
Maximum Height (mm)
4000
Add to project
T106037 (EN)
Share
Email Facebook Twitter Linkedin
Print
Add to project
  • Description
  • Standards
  • Products
  • Details
  • Documents
  • Test Reports
  • Installation
  • Related Case Studies

Standards

Standards Standard types
StandardsBS EN ISO 10140-2,Acoustics - Laboratory measurement of sound insulation of building elements. Measurement of airborne sound insulation. Standard types
StandardsBS EN 1364-1,Fire resistance tests for non-loadbearing elements - Walls. Standard types

Products

Board side 2 Layer 1: Glasroc X Sheathing Board 12.5mm
Stud fixing British Gypsum Wafer Head Jack-Point Screws 13mm
Screws side 1 Layer 1: British Gypsum Jack-Point Screws 25mm
Layer 2: British Gypsum Jack-Point Screws 41mm
Sealant Gyproc Sealant
External board joints Glasroc X Sealant
Board side 1 Layer 1: Gyproc SoundBloc 15mm
Layer 2: Gyproc SoundBloc 15mm
Screws side 2 Layer 1: Glasroc X Screws 25mm
Insulation Layer 1: 50mm Isover Acoustic Partition Roll (APR 1200)
Fixing strap Gypframe GFS1 Fixing Strap
Abutments and openings 100mm Intrastack SFS Stud
Stud 100mm Intrastack SFS Stud
Base channel 104mm Intrastack SFS Channel
Head channel 104mm Intrastack SFS Channel
External board joints (alternative) Glasroc X Sealing Tape White

Details

This section should be read in conjunction with the Products list.

  • Abutment Fixing: SFS stud (100mm x 50mm x 1.2mm) suitably fixed to structure at 600mm centres.
  • Base Channel Fixing: SFS channel (104mm x 40mm x 1.2mm) suitably fixed to floor at 600mm centres. All SFS components are supplied direct from Intrastack.
  • Deflection Allowance: For vertical movement up to 20mm. To be determined by a Structural Engineer.
  • Dropped Soffit: For principles of deflection head construction refer to detail ST‐225-ZZL2-03
  • Finishing Requirements: To achieve the specified performances, the system should be finished using either one of our Thistle or ThistlePro plasters, or Gyproc jointing products to the internal face. See the product range guides on the British Gypsum website for more information.
  • Fixing Strap: Used to support horizontal board joints to internal side and enable board screw fixing at 300mm centres.
  • Loadbearing: No
  • Maximum Height: The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the lower of the two.
  • Other Requirements: GypLyner Xternal is covered by the Saint-Gobain full system warranty combining SpecSure® Warranty and Intrastack design-life up to 250-years*.

    SpecSure
    ® system performance warranty confirms that British Gypsum proprietary systems will perform as specified for the lifetime of the building. The SpecSure® warranty requires that all components are specified in full and constructed in accordance with British Gypsum’s installation guidance. For more details see the British Gypsum website. Always check with the design team before making any changes to the chosen specification, ensuring appropriate substantiation is sought to confirm that the solution still meets all required project performances.

    *Assumed first maintenance at 60 years, and that building purpose and/or its required performance does not differ from which the Intrastack SFS was first designed.
  • Screw: Board side 1, Layer 1 (inner), fix securely to SFS supports around the perimeter of the board at maximum 300mm centres except the head channel; Board side 1, Layer 2 (outer), fix securely to all SFS supports around the perimeter of the board and intermediate stud positions at maximum 300mm centres except the head channel. The uppermost board fixings are positioned 130mm below the structural soffit through board in to fixing strap. Board side 2, Layer 1, fix securely to all SFS supports around the perimeter of the board and intermediate stud positions at maximum 300mm centres except the head channel. The uppermost board fixings are positioned 130mm below the structural soffit. External corners reduce fixings to 200mm. All joints staggered between layers. First fixing of the external board into the stud should be 100mm above the floor channel leg and then fixed working up the stud (board side 2). Fix working from the centre of each board on the internal side (board side 1). Position screws not less than 13mm from cut edges and 10mm from bound edges of boards. Set screw heads flush with plasterboard surface; do not break gypsum core.
  • Sealant: On the internal side, locate sealant at junctions with adjoining structure and other air paths. Apply as a continuous bead to clean, dry, dust-free surfaces, leaving no gaps. After application of sealant, bulk fill gaps between floor and underside of plasterboard using Gyproc joint compound.
  • Stud Centres (mm): 600 mm
  • Approx. Weight (kg/m2): 43 kg/m²
  • Head Channel Fixing: SFS slotted channel (104mm x 70mm x 2.0mm) suitably fixed to soffit at 600mm centres.
  • External board joints: Apply a continuous 6mm bead of Glasroc X Sealant along vertical and horizontal edges of board where boards will abut each other. Push the sheathing board up to the previous board ensuring the sealant 'mushroomed' out fully sealing the joint.
  • Stud Fixing: SFS studs (100mm x 50mm x 1.2mm) should be cut 25mm short and engaged into the slotted head channel and fixed through the slots with British Gypsum Wafer Head Jack-Point Screws 13mm each side of stud (25mm below the top of the slot)
  • External board joints (alternative): Before installation of the tape, be sure that joints are dry and free from oil, grease and dust. Remove the protecting film, apply the Glasroc X Sealing Tape White from the nearest horizontal joint downwards on the vertical joint. Pull the tape to the side at the same time as you pull the tape down and press it firmly against the substrate. Tape the horizontal joint. Overlapping the tape by approximately 15 mm. Tape the next vertical joint. Overlapping of tape must be a minimum of 25 mm on the vertical tape. When splicing tape, there must be an overlap of approximately 50 mm. It is recommended to use a suitable roller across the tape to ensure sufficient adhesion.

Documents

Select all
Certificates
2 datasheets related with the system
2 datasheets related with the system
BBA - Glasroc X Sheathing Board
.pdf | 1.39 MB
View
Download
BSI - BES 6001
.pdf | 1.01 MB
View
Download
BIM files
2 datasheets related with the system
2 datasheets related with the system
British-Gypsum-BIM-Material-File.adsklib
.adsklib | 2.74 MB
British-Gypsum-BIM-T106037-(EN).rvt
.rvt | 856.00 KB
Technical Specification
1 datasheet related with the system
1 datasheet related with the system
British-Gypsum-TS-T106037-EN.pdf
.pdf | 178.00 KB
Test reports
3 datasheets related with the system
3 datasheets related with the system
BTC 23531A.pdf
.pdf | 450.07 KB
BTC_23200F.pdf
.pdf | 1.78 MB
BTC_23201F.pdf
.pdf | 2.02 MB
Construction details (.dwg)
5 datasheets related with the system
5 datasheets related with the system
CN-225-010-GLX-external-SFS-wall-window-opening-SFS-2L-EN.dwg
.dwg | 195.46 KB
CN-225-012-GLX-polterm-wall-elevation-stress-plate-EN-120-minutes.dwg
.dwg | 198.68 KB
CN-225-013-GLX-20mm-def-head-slotted-channel-EN-90-minutes.dwg
.dwg | 224.22 KB
CN-225-014-GLX-external-corner-EN-90-minutes.dwg
.dwg | 147.78 KB
CN-225-015-GLX-internal-corner-EN-90-minutes.dwg
.dwg | 219.90 KB
Construction details (PDF)
5 datasheets related with the system
5 datasheets related with the system
CN-225-010-GLX-external-SFS-wall-window-opening-SFS-2L-EN.pdf
.pdf | 294.59 KB
View
Download
CN-225-012-GLX-polterm-wall-elevation-stress-plate-EN-120-minutes.pdf
.pdf | 275.89 KB
View
Download
CN-225-013-GLX-20mm-def-head-slotted-channel-EN-90-minutes.pdf
.pdf | 271.64 KB
View
Download
CN-225-014-GLX-external-corner-EN-90-minutes.pdf
.pdf | 282.10 KB
View
Download
CN-225-015-GLX-internal-corner-EN-90-minutes.pdf
.pdf | 282.62 KB
View
Download
Declaration Of Performance (DoP)
11 datasheets related with the system
11 datasheets related with the system
DoP - 0007 CE - Isover Acoustic Partition Roll
.pdf | 176.62 KB
View
Download
DoP - 0007 UK - Isover Acoustic Partition Roll
.pdf | 176.79 KB
View
Download
DoP - BOARD109 - Gyproc SoundBloc
.pdf | 141.70 KB
View
Download
DoP - BOARD109 UK - Gyproc SoundBloc
.pdf | 98.69 KB
View
Download
DoP - BOARD134 UK - Glasroc X Sheathing Board
.pdf | 76.05 KB
View
Download
DoP - FIX100 - British Gypsum Screws
.pdf | 97.60 KB
View
Download
DoP - FIX100 UK - British Gypsum Screws
.pdf | 79.36 KB
View
Download
DoP - M100 - Gypframe Metal Profiles
.pdf | 100.90 KB
View
Download
DoP - M100 UK - Gypframe Metal Profiles
.pdf | 82.57 KB
View
Download
DOP - SEAL101 - Glasroc X Sealant
.pdf | 144.20 KB
View
Download
DoP - SEAL101 UK - Glasroc X Sealant
.pdf | 91.30 KB
View
Download
Environmental Product Declaration (EPD)
2 datasheets related with the system
2 datasheets related with the system
EPD - Gypframe metal profiles
.pdf | 1.72 MB
View
Download
EPD - Gyproc SoundBloc 15mm
.pdf | 1.96 MB
View
Download
Indoor Air Quality
2 datasheets related with the system
2 datasheets related with the system
IAC-497-01-07-2025 - Indoor Air Comfort Certificate EN
.pdf | 1.23 MB
View
Download
IACG-497-01-05-2024 - Indoor Air Comfort Gold Certificate (EN)
.pdf | 1.12 MB
View
Download
Installation Guide
1 datasheet related with the system
1 datasheet related with the system
Installation Guide - Glasroc X Sheathing Board
.pdf | 8.36 MB
View
Download
Safety Data Sheet (SDS)
7 datasheets related with the system
7 datasheets related with the system
Isover Safe Use Instruction Sheet
.pdf | 50.57 KB
View
Download
SDS - British Gypsum fixings
.pdf | 517.14 KB
View
Download
SDS - Glasroc X Sealant
.pdf | 373.80 KB
View
Download
SDS - Glasroc X Sheathing Board
.pdf | 516.37 KB
View
Download
SDS - Gypframe metal products
.pdf | 663.71 KB
View
Download
SDS - Gyproc Sealant
.pdf | 513.23 KB
View
Download
SDS - Gyproc SoundBloc
.pdf | 470.02 KB
View
Download
Product Data Sheet (PDS)
11 datasheets related with the system
11 datasheets related with the system
PDS - Glasroc X Screws 25mm
.pdf | 132.76 KB
View
Download
PDS - Glasroc X Sealant
.pdf | 153.23 KB
View
Download
PDS - Glasroc X Sealing Tape White
.pdf | 161.73 KB
View
Download
PDS - Glasroc X Sheathing Board 12.5mm
.pdf | 187.57 KB
View
Download
PDS - Gypframe GFS1 Fixing Strap
.pdf | 166.62 KB
View
Download
PDS - Gyproc Sealant
.pdf | 147.49 KB
View
Download
PDS - Gyproc SoundBloc 15mm
.pdf | 212.14 KB
View
Download
PDS - Isover Acoustic Partition Roll (APR 1200)
.pdf | 652.89 KB
View
Download
PDS - Jack Point Screws 25mm
.pdf | 160.63 KB
View
Download
PDS - Jack Point Screws 41mm
.pdf | 167.56 KB
View
Download
PDS - Wafer Head Jack Point Screws 13mm
.pdf | 147.91 KB
View
Download
Product selector guide
2 datasheets related with the system
2 datasheets related with the system
Selector Guide - Plasterboard
.pdf | 594.86 KB
View
Download
Selector Guide - Specialist boards
.pdf | 571.69 KB
View
Download
CAD details (.dwg)
1 datasheet related with the system
1 datasheet related with the system
ST-225-ZZL2-03-20mm-def-head-slotted-channel-EN-90-minutes.dwg
.dwg | 160.22 KB
CAD details (PDF)
1 datasheet related with the system
1 datasheet related with the system
ST-225-ZZL2-03-20mm-def-head-slotted-channel-EN-90-minutes.pdf
.pdf | 270.73 KB
View
Download
White Book
2 datasheets related with the system
2 datasheets related with the system
The White Book
.pdf | 50.91 MB
View
Download
White Book - GypLyner Xternal
.pdf | 1006.76 KB
View
Download

Our website ALWAYS carries the latest and most up to date version of all of these documents, but on occasion there is a need for previous versions. If you do require a previous version of documents related to the products that make up this specification click here

Need CAD, BIM, Test Reports and Technical Specifications?

Log in to access CAD .dwg files.

Log in and add a System Specification to a Project to access BIM files, Test Reports, and Technical Specification files.

login

Test Reports

Please add this Specification to a project and go to that Project to access the related Test Reports.

Test report label Test report name
Test report labelSound Insulation Test Report Test report nameBTC 23531A
Test report labelFire Resistance Test Report Test report nameBTC 23200F
Test report nameBTC 23201F
Image
Product Specification Search
The White Book Specification Selector
Find system specifications that match your needs
Show all specifications
British Gypsum UK

SpecSure

A unique warranty that confirms British Gypsum proprietary systems will perform as specified for the lifetime of the building.

Learn more
Facebook
X
Youtube
LinkedIn
Instagram
Footer left menu
  • About Us
  • Building Better Communities
  • Corporate Governance
  • Careers
  • Cookie Policy
  • Privacy Policy
Saint-Gobain

Saint-Gobain Construction Products UK Limited trading as British Gypsum. Registered Office Saint-Gobain House, East Leake, Loughborough, Leicestershire. LE12 6JU.
Company Number 00734396. VAT No: GB 438 3065 50

© Saint-Gobain Construction Products UK Limited 2026. All rights reserved.

  • Product
  • Specification
Compare
Export the list in .csv
Compare