Image

Wall Linings

Our versatile specifications cater for a range of wall and roof constructions, including-metal frame and traditional masonry.

We cover all wall lining applications, from high-performance solutions that meet thermal, acoustic, fire-protection or impact-resistance requirements.

Linings can be fully or partially independent of the structure, or can simply be bonded or plastered directly to a wall surface. These systems can be used in all types of buildings and are equally suited to both new-build and refurbishment work.

Please note that all British Gypsum Drylining systems are tested to the BS EN fire test standard. However we can continue to support your BS Standard Specifications project with remaining test evidence to BS 476. Please click here for more information.

 

Watch this short video to see how to use this EN Specification Selector and where you can still get details of our BS Specifications.

Filter your results
Apply filters
Filter
Fire Integrity (mins)
min
max
Fire Insulation (mins)
min
max
Sound Insulation (Airborne) Rw (dB)
min
max
Sound Insulation (Airborne) Rw + Ctr (dB)
min
max
Maximum Height (mm)
min
max
Stud Type
Products used
158 Solutions

B216003 (A) (EN)

Two layers of Gyproc WallBoard 12.5mm to one side of Gypframe 48 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 2700mm.

Fire Integrity (mins)
30
Fire Insulation (mins)
30
Maximum Height (mm)
2700
Duty Rating
Severe

B216003 (A) MR1 (EN)

Inner layer of Gyproc WallBoard 12.5mm with an outer layer of Gyproc Moisture Resistant 12.5mm to one side of Gypframe 48 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 2700mm.

Fire Integrity (mins)
30
Fire Insulation (mins)
30
Maximum Height (mm)
2700
Duty Rating
Severe

B216003 (B) (EN)

Two layers of Gyproc WallBoard 12.5mm to one side of Gypframe 60 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3000mm.

Fire Integrity (mins)
30
Fire Insulation (mins)
30
Maximum Height (mm)
3000
Duty Rating
Severe

B216003 (B) MR1 (EN)

Inner layer of Gyproc WallBoard 12.5mm with an outer layer of Gyproc Moisture Resistant 12.5mm to one side of Gypframe 60 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3000mm.

Fire Integrity (mins)
30
Fire Insulation (mins)
30
Maximum Height (mm)
3000
Duty Rating
Severe

B216003 (C) (EN)

Two layers of Gyproc WallBoard 12.5mm to one side of Gypframe 60 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3600mm.

Fire Integrity (mins)
30
Fire Insulation (mins)
30
Maximum Height (mm)
3600
Duty Rating
Severe

B216003 (C) MR1 (EN)

Inner layer of Gyproc WallBoard 12.5mm with an outer layer of Gyproc Moisture Resistant 12.5mm to one side of Gypframe 60 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3600mm.

Fire Integrity (mins)
30
Fire Insulation (mins)
30
Maximum Height (mm)
3600
Duty Rating
Severe

B216003 (D) (EN)

Two layers of Gyproc WallBoard 12.5mm to one side of Gypframe 70 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.

Fire Integrity (mins)
30
Fire Insulation (mins)
30
Maximum Height (mm)
4000
Duty Rating
Severe

B216003 (D) MR1 (EN)

Inner layer of Gyproc WallBoard 12.5mm with an outer layer of Gyproc Moisture Resistant 12.5mm to one side of Gypframe 70 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.

Fire Integrity (mins)
30
Fire Insulation (mins)
30
Maximum Height (mm)
4000
Duty Rating
Severe

B216003 (E) (EN)

Two layers of Gyproc WallBoard 12.5mm to one side of Gypframe 92 I 90 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.

Fire Integrity (mins)
30
Fire Insulation (mins)
30
Maximum Height (mm)
4000
Duty Rating
Severe