Image

Wall Linings

Our versatile specifications cater for a range of wall and roof constructions, including-metal frame and traditional masonry.

We cover all wall lining applications, from high-performance solutions that meet thermal, acoustic, fire-protection or impact-resistance requirements.

Linings can be fully or partially independent of the structure, or can simply be bonded or plastered directly to a wall surface. These systems can be used in all types of buildings and are equally suited to both new-build and refurbishment work.

To see all Specifications that use a particular Product, please go to the Product page and look for the ‘Show me all specifications that use this product’ option. To see all Specifications for a particular System, please go to the System page and look for the ‘Show all specifications for this system’ option.

For the latest information on BS Standard Specifications please click here.

Filter your results
Apply filters
Filter
Fire Integrity (mins)
min
max
Fire Insulation (mins)
min
max
Sound Insulation (Airborne) Rw (dB)
min
max
Sound Insulation (Airborne) Rw + Ctr (dB)
min
max
Maximum Height (mm)
min
max
101 Solutions
Specification Sort descending Cavity / Offset (mm) - Min. Cavity / Offset (mm) - Max. Fire Integrity (mins) Fire Insulation (mins) Sound Insulation (Airborne) Rw (dB) Sound Insulation (Airborne) Rw + Ctr (dB) Maximum Height (mm) Duty Rating Stud Centres (mm) Framework / lining Primary framework centres (mm) Approx. weight kg/m2
B216003 (A) (EN) 30 30 30 2700 Severe 600 18
B216003 (B) (EN) 30 30 30 3000 Severe 600 18
B216003 (C) (EN) 30 30 30 3600 Severe 600 19
B216003 (D) (EN) 30 30 30 4000 Severe 600 19
B216003 (E) (EN) 30 30 30 4000 Severe 600 20
B216003 (F) (EN) 30 30 30 4000 Severe 600 20
B216004 (A) (EN) 30 30 30 2800 Severe 600 20
B216004 (B) (EN) 30 30 30 3300 Severe 600 21
B216004 (C) (EN) 30 30 30 3900 Severe 600 21