!*
Skip to main content
toggle menu
Home
User account menu
  • Products
  • White Book Specification Selector
  • Log in / Register
Main navigation
  • Inspiration
    Building Better
    • Project Showcase
    Learn more
    Thought Leadership
    • Thought Leadership Articles
    • Thought Leaders
    Learn more
    The Build Better Centre
    Learn more
  • Specification
    White Book Specification Selector
    • White Book Overview
    • Ceilings
    • External Walls
    • Floors
    • Horizontal ShaftWall
    • Internal Partitions & Walls
    • Shaftwall
    • Steel Protection
    • Thistle Plaster Systems
    • Wall Linings
    • BS Specifications
      Display in two columns
      Off
    Learn more
    Our Products
    • Acoustic ceiling systems
    • British Gypsum fixings
    • Gypframe
    • Gyproc jointing products
    • Gyproc plasterboards
    • Thistle plasters
    Learn more
    Resources and Literature
    • All literature
    • Declaration of Performance
    • Product Data Sheets
    • Safety Data Sheets
    • Environmental Product Declarations
    Learn more
    SpecSure® System Warranty
    Learn more
  • Installation
    Our Products
    • Acoustic ceiling systems
    • British Gypsum fixings
    • Gypframe
    • Gyproc jointing products
    • Gyproc plasterboards
    • Thistle plasters
    Learn more
    The Plasterer’s Hub
    • Join the Certified Plasterer Scheme
    • Find a Certified Plasterer
    Learn more
    Installation Guidance and Support
    • Installation Guides
    • Product, project and training support
    Learn more
    Stockist Locator
    Learn more
  • Skills Development
    Upskilling Courses
    • Book a course
    • Training Prospectus
      Display in two columns
      Off
      Background color
      Grey
    • Training Academies
    Learn more
    Students, Apprentices and New Trainees
    • Partnership Colleges
    • Students and Apprentices
    Learn more
    E-Learning
    • Our Platform and Courses
    Learn more
  • Technical Support
    Self Help Tools
    • FAQs
    • Plaster Coverage Calculator
    • Thermal Calculator
    • Design Guidance
    • Resources and Literature
    Learn more
    Technical Consultancy
    • Technical Enquiry Form
    Learn more
    SpecSure® System Warranty
    Learn more
  • Customer Services
    Services
    • Distribution Innovation
    • Track and Trace
    Learn more
Search
Breadcrumb
  1. Home
  2. Specification
  3. White Book Specification Selector
  4. Shaftwall
  5. GypWall Shaft
  6. G306006 (B) (EN)
Help menu
Last reviewed:
22.09.2021
Last updated:
22.07.2022
Image
Share
Email Facebook Twitter Linkedin
Print
Bookmark this page
Download
GypWall Shaft

G306006 (B) (EN)

Gypframe 92 I 90 ‘I’ Studs at 600mm centres with Glasroc F FireCase 20mm between studs, secured by Gypframe G105 Retaining Channel. Two layers of Glasroc F FireCase 15mm to non-shaft side. For heights up to 6000mm.

Read more
Read less
Fire Integrity (mins)
90
Fire Insulation (mins)
90
Sound Insulation (Airborne) Rw (dB)
43
Duty Rating
Severe
Maximum Height (mm)
6000
Partition Thickness (mm)
124
Add to project
G306006 (B) (EN)
Share
Email Facebook Twitter Linkedin
Print
Add to project
  • Description
  • Standards
  • Products
  • Details
  • Documents
  • Test Reports
  • Installation
  • Related Case Studies

Standards

Standards Standard types
StandardsBS EN 1364-1,Fire resistance tests for non-loadbearing elements - Walls. Standard types
StandardsBS EN ISO 140-3,Acoustics - Measurement of sound insulation in buildings and of building elements. Laboratory measurement of airborne sound insulation of building elements. Standard types
StandardsBS 5234-2,Specification for performance requirements for strength and robustness including methods of test. Standard types

Products

Board side 1 Layer 1: Glasroc F FireCase 15mm
Layer 2: Glasroc F FireCase 15mm
Screws side 1 Layer 1: British Gypsum Jack-Point Screws 35mm
Layer 2: British Gypsum Jack-Point Screws 41mm
Sealant Gyproc Sealant
Retaining channel Gypframe G105 Retaining Channel
Horizontal joint Glasroc F FireCase 20mm
Gypframe GA3 Steel Angle
Core Glasroc F FireCase 20mm
Stud Gypframe 92 I 90 'I' Stud
Fixing strap Gypframe GFS1 Fixing Strap
Abutment channel Gypframe 92 SC 90 Starter Channel
Base channel Gypframe 94 DC 60 Deep Flange Floor & Ceiling Channel
Head channel Gypframe 94 EDC 70 Extra Deep Flange Floor & Ceiling Channel

Details

This section should be read in conjunction with the Products list.

  • Abutment Fixing: Gypframe starter channel suitably fixed wall at 600mm centres in two lines staggered by 300mm.
  • Base Channel Fixing: Gypframe channel suitably fixed to floor at 600mm centres in two lines staggered by 300mm.
  • Deflection Allowance: Vertical deflection only. To be determined by a Structural Engineer.
  • Dropped Soffit: For principles of deflection head construction refer to detail ST‐129‐Z2L2‐08.
  • Finishing Requirements: To achieve the specified performances, the system should be finished using either one of our Thistle or ThistlePro plasters, or Gyproc jointing products. See the product range guides on the British Gypsum website for more information.
  • Fixing Strap: Used to support horizontal board joints in face layer of multiple layer board linings and enable board screw fixing at 300mm centres.
  • Horizontal Joint: Horizontal board joints in core layer closed off by inserting steel angle between board joints and 122mm strip of core board fire stop with beads of sealant along both longer edges fixed to angle using three drywall screws.
  • Loadbearing: No
  • Maximum Height: The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the lower of the two.
  • Other Requirements: SpecSure® system performance warranty confirms that British Gypsum proprietary systems will perform as specified for the lifetime of the building. The SpecSure® warranty requires that all components are specified in full and constructed in accordance with British Gypsum’s installation guidance. For more details see the British Gypsum website. Always check with the design team before making any changes to the chosen specification, ensuring appropriate substantiation is sought to confirm that the solution still meets all required project performances.
  • Retaining Channel: Retaining channels inserted between the face of the coreboard and the flange of the stud / starter channel.
  • Screw: Board layers are fixed securely to Gypframe metal supports around the perimeter of the board and intermediate stud positions at maximum 300mm centres. External corners reduce fixings to 200mm. Drywall screws can be used for fixing boards to metal profiles with a thickness of 0.8mm or less (excluding 'I' studs). All joints staggered between layers. Fix working from the centre of each board. Position screws not less than 13mm from edges of boards. Set screw heads flush with plasterboard surface; do not break gypsum core.
  • Sealant: Locate sealant at junctions with adjoining structure and other air paths. Apply as a continuous bead to clean, dry, dust-free surfaces, leaving no gaps. After application of sealant, bulk fill gaps between floor and underside of plasterboard using Gyproc jointing compound. For pressurised airshafts and service ducts apply a continuous bead of sealant leaving no gaps to all framing members at perimeter junctions with walls, floors and ceilings, air gaps around openings, and other potential air leakage points. To frame members prior to fitting core boards and around fire stops cloaking horizontal core board joints. To all metal framing around board perimeters of first layer boarding and board perimeters when fixing outer layer board.
  • Stud Centres (mm): 600 mm
  • Approx. Weight (kg/m2): 47 kg/m²
  • Head Channel Fixing: Gypframe channel suitably fixed through fire stop in to soffit at 600mm centres in two lines staggered by 300mm.

Documents

Select all
Certificates
2 datasheets related with the system
2 datasheets related with the system
BBA - Glasroc F FireCase
.pdf | 2.16 MB
View
Download
BSI - BES 6001
.pdf | 772.38 KB
View
Download
CAD details (PDF)
5 datasheets related with the system
5 datasheets related with the system
CAD details (PDF)
.pdf | 1.26 MB
View
Download
CAD details (PDF)
.pdf | 320.18 KB
View
Download
CAD details (PDF)
.pdf | 321.40 KB
View
Download
CAD details (PDF)
.pdf | 319.40 KB
View
Download
CN-624-004-GypWall-Shaft-opening-width-up-to-1200mm.pdf
.pdf | 273.27 KB
View
Download
CAD details (.dwg)
10 datasheets related with the system
10 datasheets related with the system
CN-129-002-GWS-def-head-para-perp-profile-soffit-2-layers-EN-90-minutes.dwg
.dwg | 178.08 KB
CAD details (.dwg)
.dwg | 154.59 KB
View
Download
CAD details (.dwg)
.dwg | 173.78 KB
View
Download
CN-624-004-GypWall-Shaft-opening-width-up-to-1200mm.dwg
.dwg | 105.24 KB
CAD details (.dwg)
.dwg | 125.33 KB
View
Download
CAD details (.dwg)
.dwg | 143.06 KB
View
Download
CAD details (.dwg)
.dwg | 123.53 KB
View
Download
CAD details (.dwg)
.dwg | 114.67 KB
View
Download
CAD details (.dwg)
.dwg | 126.77 KB
View
Download
CAD details (.dwg)
.dwg | 158.05 KB
View
Download
Declaration Of Performance (DoP)
7 datasheets related with the system
7 datasheets related with the system
DoP - FIX100 - British Gypsum Screws
.pdf | 121.11 KB
View
Download
DoP - FIX100 UK - British Gypsum Screws
.pdf | 99.67 KB
View
Download
DoP - GLAS102 - Glasroc F FireCase
.pdf | 160.01 KB
View
Download
DoP - M100 - Gypframe Metal Profiles
.pdf | 124.49 KB
View
Download
DoP - M100 UK - Gypframe Metal Profiles
.pdf | 93.55 KB
View
Download
DoP - SEAL100 UK - Gyproc Sealant (5015341270970)
.pdf | 95.03 KB
View
Download
DoP - SEAL102 - Gyproc Sealant (5015341302152)
.pdf | 128.18 KB
View
Download
Environmental Product Declaration (EPD)
2 datasheets related with the system
2 datasheets related with the system
EPD - Glasroc F FireCase 15mm
.pdf | 1.94 MB
View
Download
EPD - Gypframe metal framing components
.pdf | 1.57 MB
View
Download
Product Data Sheet (PDS)
12 datasheets related with the system
12 datasheets related with the system
PDS - Glasroc F FireCase 15mm
.pdf | 190.81 KB
View
Download
PDS - Glasroc F FireCase 20mm
.pdf | 186.48 KB
View
Download
PDS - Gypframe 92 I 90 'I' Stud
.pdf | 269.59 KB
View
Download
PDS - Gypframe 92 SC 90 Starter Channel
.pdf | 174.67 KB
View
Download
PDS - Gypframe 94 DC 60 Deep Flange Floor & Ceiling Channel
.pdf | 225.21 KB
View
Download
PDS - Gypframe 94 EDC 70 Extra Deep Flange Floor & Ceiling Channel
.pdf | 261.48 KB
View
Download
PDS - Gypframe G105 Retaining Channel
.pdf | 231.49 KB
View
Download
PDS - Gypframe GA3 Steel Angle
.pdf | 155.34 KB
View
Download
PDS - Gypframe GFS1 Fixing Strap
.pdf | 204.65 KB
View
Download
PDS - Gyproc Sealant
.pdf | 234.22 KB
View
Download
PDS - Jack Point Screws 35mm
.pdf | 189.35 KB
View
Download
PDS - Jack Point Screws 41mm
.pdf | 194.41 KB
View
Download
Safety Data Sheet (SDS)
4 datasheets related with the system
4 datasheets related with the system
SDS - British Gypsum fixings
.pdf | 517.14 KB
View
Download
SDS - Glasroc F FireCase
.pdf | 474.86 KB
View
Download
SDS - Gypframe metal products
.pdf | 658.56 KB
View
Download
SDS - Gyproc Sealant
.pdf | 513.23 KB
View
Download
Product selector guide
1 datasheet related with the system
1 datasheet related with the system
Selector Guide - Specialist boards
.pdf | 571.69 KB
View
Download
White Book
3 datasheets related with the system
3 datasheets related with the system
White Book - Finishes
.pdf | 18.28 MB
View
Download
White Book
.pdf | 8.01 MB
View
Download
White Book - System design principles
.pdf | 3.59 MB
View
Download

If you require previous versions of the documentation related to the products that make up this specification, please click here

Need CAD, BIM, Test Reports and Technical Specifications?

Log in to access CAD .dwg files.

Log in and add a System Specification to a Project to access BIM files, Test Reports, and Technical Specification files.

login

Test Reports

Please add this Specification to a project and go to that Project to access the related Test Reports.

Test report label Test report name
Test report labelFire Resistance Test Report Test report nameBTC 16887FA
Test report labelFire Height Test Report Test report nameBTC 16887FA
Test report labelSound Insulation Test Report Test report nameBG G306 A
Image
The White Book Specification Selector
Find system specifications that match your needs
Show all specifications
British Gypsum UK

SpecSure

A unique warranty that confirms British Gypsum proprietary systems will perform as specified for the lifetime of the building.

Learn more
Facebook
Twitter
Youtube
LinkedIn
Instagram
Footer left menu
  • About Us
  • Sustainability
  • Building Better Communities
  • Corporate Governance
  • Careers
  • Cookie Policy
  • Privacy Policy
Saint-Gobain

Saint-Gobain Construction Products UK Limited trading as British Gypsum. Registered Office Saint-Gobain House, East Leake, Loughborough, Leicestershire. LE12 6JU.
Company Number 00734396. VAT No: GB 438 3065 50

© Saint-Gobain Construction Products UK Limited 2022. All rights reserved.

  • Product
  • Specification
Compare
Export the list in .csv
Compare