A206264S (EN)
One layer of Gyproc SoundBloc 15mm each side of Gypframe 92 S 50 'C' Studs at 600mm centres. 100mm Isover Modular Roll in the cavity with 2mm Thistle MultiFinish on each side. For heights up to 4000mm.
Read more
Read less
Fire Integrity (mins)
30
Fire Insulation (mins)
30
Sound Insulation (Airborne) Rw (dB)
52
Maximum Height (mm)
4000
Partition Thickness (mm)
128
Standards
Standards | Standard types |
---|---|
StandardsBS EN ISO 10140-2,Acoustics - Laboratory measurement of sound insulation of building elements. Measurement of airborne sound insulation. | Standard types |
StandardsBS 5234-2,Specification for performance requirements for strength and robustness including methods of test. | Standard types |
StandardsBS EN 1364-1,Fire resistance tests for non-loadbearing elements - Walls. | Standard types |
Products
Insulation | Layer 1: 100mm Isover Modular Roll |
Screws side 1 | Layer 1: British Gypsum Drywall Screws 25mm |
Screws side 2 | Layer 1: British Gypsum Drywall Screws 25mm |
Finish coat | Side 1: Thistle MultiFinish Side 2: Thistle MultiFinish |
Fixing strap | Gypframe GFS1 Fixing Strap |
Fixing T | Gypframe GFT1 Fixing 'T' |
Stud | Gypframe 92 S 50 'C' Stud |
Abutments and openings | Gypframe 92 S 50 'C' Stud |
Base channel | Gypframe 94 FEC 50 Folded Edge Standard Floor & Ceiling Channel |
Head channel | Gypframe 94 FEC 50 Folded Edge Standard Floor & Ceiling Channel |
Board side 1 | Layer 1: Gyproc SoundBloc 15mm |
Board side 2 | Layer 1: Gyproc SoundBloc 15mm |
Sealant | Gyproc Sealant |
Details
This section should be read in conjunction with the Products list.
- Abutment Fixing: Gypframe 'C' stud suitably fixed to structure at 600mm centres in two lines staggered by 300mm.
- Base Channel Fixing: Gypframe channel suitably fixed to floor at 600mm centres in two lines staggered by 300mm.
- Deflection Allowance: Vertical deflection only. To be determined by a Structural Engineer.
- Dropped Soffit: For principles of deflection head construction refer to detail ST‐121‐Z1L1‐08.
- Finish Coat Thickness - Side 1 (mm): 2 mm
- Finish Coat Thickness - Side 2 (mm): 2 mm
- Fixing Strap: Used to support horizontal board joints and enable board screw fixing at 300mm centres.
- Fixing T: Used to support horizontal board joints and enable board screw fixing at 300mm centres.
- Loadbearing: No
- Maximum Height: The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the lower of the two.
- Other Requirements: SpecSure® system performance warranty confirms that British Gypsum proprietary systems will perform as specified for the lifetime of the building. The SpecSure® warranty requires that all components are specified in full and constructed in accordance with British Gypsum’s installation guidance. For more details see the British Gypsum website. Always check with the design team before making any changes to the chosen specification, ensuring appropriate substantiation is sought to confirm that the solution still meets all required project performances.
- Screw: Board layer 1, fix securely to Gypframe metal supports around the perimeter of the board and intermediate stud positions at maximum 300mm centres. External corners reduce fixings to 200mm. All joints staggered between layers. Fix working from the centre of each board. Position screws not less than 13mm from cut edges and 10mm from bound edges of boards. Set screw heads flush with plasterboard surface; do not break paper or gypsum core.
- Sealant: Locate sealant at junctions with adjoining structure and other air paths. Apply as a continuous bead to clean, dry, dust-free surfaces, leaving no gaps. After application of sealant, bulk fill gaps between floor and underside of plasterboard using Gyproc joint compound.
- Sound Insulation: Including skim finish to both sides.
- Stud Centres (mm): 600 mm
- Approx. Weight (kg/m2): 27 kg/m²
- Head Channel Fixing: Gypframe channel suitably fixed to soffit at 600mm centres in two lines staggered by 300mm.
Documents
Need CAD, BIM, Test Reports and Technical Specifications?
Log in to access CAD .dwg files.
Log in and add a System Specification to a Project to access BIM files, Test Reports, and Technical Specification files.
Test Reports
Please add this Specification to a project and go to that Project to access the related Test Reports.
Test report label | Test report name |
---|---|
Test report labelFire Resistance Test Report | Test report nameBTC 16492F |
Test report labelSound Insulation Test Report | Test report nameA206264S LC |
Test report labelPartition Duty Test Report | Test report nameBTC 16316LC |

SpecSure
A unique warranty that confirms British Gypsum proprietary systems will perform as specified for the lifetime of the building.