Skip to main content
toggle menu
Home
User account menu
  • Products
  • Stockists
  • White Book Specification Selector
  • Log in / Register
Main navigation
  • Inspiration
    Building Better
    • Building Better Hub
    • Project Showcase
    Learn more
    Saint-Gobain Solutions Centre
    Learn more
  • Specification
    White Book Specification Selector
    • White Book Overview
    • Ceilings
    • External Walls
    • Floors
    • Horizontal ShaftWall
    • Internal Partitions & Walls
    • Shaftwall
    • Steel Protection
    • Thistle Plaster Systems
    • Timber Frame
      Display in two columns
      Off
    • Wall Linings
    • BS Specifications
      Display in two columns
      Off
    Learn more
    Our Products
    • Acoustic ceiling systems
    • British Gypsum fixings
    • Gypframe
    • Gyproc Firestopping
      Display in two columns
      Off
    • Gyproc jointing products
    • Gyproc plasterboards
    • Thistle plasters
    Learn more
    Resources and Literature
    • All literature
    • Declaration of Performance
    • Design Guidance
    • Environmental Product Declarations
    • Product Data Sheets
    • Safety Data Sheets
    Learn more
    SpecSure® System Warranty
    Learn more
  • Installation
    Our Products
    • Acoustic ceiling systems
    • British Gypsum fixings
    • Gypframe
    • Gyproc Firestopping
      Display in two columns
      Off
    • Gyproc jointing products
    • Gyproc plasterboards
    • Thistle plasters
    Learn more
    The Plasterer’s Hub
    • Join the Certified Plasterer Scheme
    • Find a Certified Plasterer
    Learn more
    Installation Guidance and Support
    • Installation Guides
    • Product, project and training support
    Learn more
    Stockist Locator
    Learn more
  • Skills Development
    Upskilling Courses
    • Book a course
    • Site Ready Skimming Course
      Display in two columns
      Off
      Background color
      Grey
    • Training Prospectus
      Display in two columns
      Off
      Background color
      Grey
    • Training Academies
    Learn more
    Students, Apprentices and New Trainees
    • Partnership Colleges
    Learn more
    E-Learning
    • Our Platform and Courses
    Learn more
    CPD Resource
    • Acoustic Design
      Display in two columns
      Off
    • Inhibiting Fire Growth
    • System Integrity
      Display in two columns
      Off
    Learn more
  • Technical Support
    Self Help Tools
    • FAQs
    • Plaster Coverage Calculator
    • Thermal Calculator
    • Design Guidance
    • Fire-Rated Junctions Guide
      Display in two columns
      Off
    • Resources and Literature
    Learn more
    Technical Consultancy
    • Technical Enquiry Form
    Learn more
    SpecSure® System Warranty
    Learn more
  • Customer Services
    Services
    • Distribution Innovation
    • Track and Trace
    Learn more
Breadcrumb
  1. Home
  2. Specification
  3. White Book Specification Selector
  4. Steel Protection
  5. FireCase
  6. D120001 (C) (EN)
Help menu
Last reviewed:
20.12.2021
Last updated:
15.04.2025
Image
Image
Share
Email Facebook Twitter Linkedin
Print
Bookmark this page
Download
FireCase

D120001 (C) (EN)

One layer of Glasroc F FireCase 15mm providing 60 minutes fire protection to steel columns up to a Section Factor A/V (HP/A) m-1 (max) of 232 at a critical temperature of 550oC.

Read more
Read less
Fire Protection (mins)
60
Framed / Frameless
Frameless
Maximum Section Factor (m-1)
232
Add to project
D120001 (C) (EN)
Share
Email Facebook Twitter Linkedin
Print
Add to project
  • Description
  • Standards
  • Products
  • Details
  • Documents
  • Test Reports
  • Installation
  • Related Case Studies

Standards

Standards Standard types
StandardsBS EN 13381-4,Test methods for determining the contribution to the fire resistance of structural members: Applied protection to steel members. Standard types

Products

Encasement board screws (board to board) Layer 1: Glasroc F FireCase Screws 40mm
Encasement board screws (board to metal) Layer 1: Glasroc F FireCase Screws 40mm
Perimeter framing Gypframe FEA1 Steel Angle
Encasement board Layer 1: Glasroc F FireCase 15mm

Details

This section should be read in conjunction with the Products list.

  • Background: Steel Column
  • Finishing Requirements: Finishing is not required to achieve the specified performance, but the system can be finished using either one of our Thistle or ThistlePro plasters, or Gyproc jointing products. See the product range guides on the British Gypsum website for more information.
  • Installation: Three sided column encasement: Fix continuous lengths of steel angle to both sides of the flange abutting the wall structure, or to the wall structure itself, using suitable fire resistant fixings at 600mm centres. Alternatively, use shot-fired fixings at the same centres. Ensure face of angle is flush with edge of flange. Use additional angles where the column flange is set at right-angles to the wall structure. Fix return boards to angles and face boards to return boards using screws. Four sided column encasement: Fix boards on adjacent faces to each other. Stagger all joints by a minimum of 600mm in adjacent layers and multi-layer linings. Ensure all boards are cut square to maintain tight butt joints with no gaps, and the board-to-board edge fixings are secured into the centre of the abutting Glasroc F FireCase board.
  • Loadbearing: No
  • Other Requirements: SpecSure® system performance warranty confirms that British Gypsum proprietary systems will perform as specified for the lifetime of the building. The SpecSure® warranty requires that all components are specified in full and constructed in accordance with British Gypsum’s installation guidance. For more details see the British Gypsum website. Always check with the design team before making any changes to the chosen specification, ensuring appropriate substantiation is sought to confirm that the solution still meets all required project performances.
  • Screw: Fix boards on adjacent faces to each other or to metal angles using screws at 150mm centres. Set screw heads flush with board surface.
  • Encasement: The maximum permitted steel size which can be encased is 600mm.

Documents

Select all
Certificates
2 datasheets related with the system
2 datasheets related with the system
BBA - Glasroc F FireCase
.pdf | 2.16 MB
View
Download
BSI - BES 6001
.pdf | 1.01 MB
View
Download
CAD details (PDF)
1 datasheet related with the system
1 datasheet related with the system
British-Gypsum-FireCase-ANL1-1-layer-Set.pdf
.pdf | 804.88 KB
View
Download
Technical Specification
1 datasheet related with the system
1 datasheet related with the system
British-Gypsum-TS-D120001-(C)-(EN).pdf
.pdf | 64.76 KB
Classification reports
1 datasheet related with the system
1 datasheet related with the system
BTC 21179FC.pdf
.pdf | 510.83 KB
Construction details (.dwg)
3 datasheets related with the system
3 datasheets related with the system
CN-421-002-FC-column-encasement-junction-spray-EN.dwg
.dwg | 154.43 KB
CN-421-003-FC-column-encasement-junction-paint-EN.dwg
.dwg | 146.49 KB
CN-422-001-GLE-column-encasement-junction-paint-EN.dwg
.dwg | 164.80 KB
Construction details (PDF)
3 datasheets related with the system
3 datasheets related with the system
CN-421-002-FC-column-encasement-junction-spray-EN.pdf
.pdf | 268.97 KB
View
Download
CN-421-003-FC-column-encasement-junction-paint-EN.pdf
.pdf | 270.16 KB
View
Download
CN-422-001-GLE-column-encasement-junction-paint-EN.pdf
.pdf | 301.32 KB
View
Download
Declaration Of Performance (DoP)
6 datasheets related with the system
6 datasheets related with the system
DoP - FIX100 - British Gypsum Screws
.pdf | 97.60 KB
View
Download
DoP - FIX100 UK - British Gypsum Screws
.pdf | 79.36 KB
View
Download
DoP - GLAS102 - Glasroc F FireCase
.pdf | 148.77 KB
View
Download
DoP - GLAS102 UK - Glasroc F FireCase
.pdf | 90.98 KB
View
Download
DoP - M100 - Gypframe Metal Profiles
.pdf | 100.90 KB
View
Download
DoP - M100 UK - Gypframe Metal Profiles
.pdf | 82.57 KB
View
Download
Environmental Product Declaration (EPD)
2 datasheets related with the system
2 datasheets related with the system
EPD - Gypframe metal profiles
.pdf | 1.72 MB
View
Download
EPD - Gypframe metal profiles - Carbon Low
.pdf | 1.03 MB
View
Download
Indoor Air Quality
1 datasheet related with the system
1 datasheet related with the system
IACG-497-01-06-2025 - Indoor Air Comfort Gold Certificate EN
.pdf | 1.25 MB
View
Download
Product Data Sheet (PDS)
3 datasheets related with the system
3 datasheets related with the system
PDS - Glasroc F FireCase 15mm
.pdf | 208.00 KB
View
Download
PDS - Glasroc F FireCase Screws 40mm
.pdf | 161.32 KB
View
Download
PDS - Gypframe FEA1 Steel Angle
.pdf | 155.50 KB
View
Download
Safety Data Sheet (SDS)
2 datasheets related with the system
2 datasheets related with the system
SDS - Glasroc F FireCase
.pdf | 474.86 KB
View
Download
SDS - Gypframe metal products
.pdf | 663.71 KB
View
Download
Product selector guide
1 datasheet related with the system
1 datasheet related with the system
Selector Guide - Specialist boards
.pdf | 571.69 KB
View
Download
CAD details (.dwg)
2 datasheets related with the system
2 datasheets related with the system
ST-421-ANL1-01-column-and-beam-4-and-3-sided.dwg
.dwg | 100.88 KB
ST-421-ANL1-02-column-and-beam-partition-junctions.dwg
.dwg | 107.13 KB
White Book
4 datasheets related with the system
4 datasheets related with the system
The White Book
.pdf | 50.91 MB
View
Download
White Book - Finishes
.pdf | 5.33 MB
View
Download
White Book - FireCase
.pdf | 1.51 MB
View
Download
White Book - System design principles
.pdf | 1.52 MB
View
Download

Our website ALWAYS carries the latest and most up to date version of all of these documents, but on occasion there is a need for previous versions. If you do require a previous version of documents related to the products that make up this specification click here

Need CAD, BIM, Test Reports and Technical Specifications?

Log in to access CAD .dwg files.

Log in and add a System Specification to a Project to access BIM files, Test Reports, and Technical Specification files.

login
Image
Product Specification Search
The White Book Specification Selector
Find system specifications that match your needs
Show all specifications
British Gypsum UK

SpecSure

A unique warranty that confirms British Gypsum proprietary systems will perform as specified for the lifetime of the building.

Learn more
Facebook
X
Youtube
LinkedIn
Instagram
Footer left menu
  • About Us
  • Building Better Communities
  • Corporate Governance
  • Careers
  • Cookie Policy
  • Privacy Policy
Saint-Gobain

Saint-Gobain Construction Products UK Limited trading as British Gypsum. Registered Office Saint-Gobain House, East Leake, Loughborough, Leicestershire. LE12 6JU.
Company Number 00734396. VAT No: GB 438 3065 50

© Saint-Gobain Construction Products UK Limited 2026. All rights reserved.

  • Product
  • Specification
Compare
Export the list in .csv
Compare