Last reviewed:
Last updated:
RF-PIR (A) (EN)
One layer of Gyproc ThermaLine PIR 38mm on Gyproc Sealant (3mm nominal cavity) on existing plastered walls, level brick, block or fair faced concrete.
Read more
Read less
Standards
Standards | Standard types |
---|---|
Standards | Standard types |
Products
Board side 1 | Layer 1: Gyproc ThermaLine PIR 38mm |
Parge coat | Gyproc SoundCoat Plus |
Fixing method | Gyproc Sealant |
Sealant | Gyproc Sealant |
Secondary fixing | British Gypsum Nailable Plugs 80mm |
Details
This section should be read in conjunction with the Products list.
- Background: Existing plastered walls or level brick, block or fair-faced concrete
- Finishing Requirements: The system should be finished using either one of our Thistle or ThistlePro plasters, or Gyproc jointing products. See the product range guides on the British Gypsum website for more information.
- Loadbearing: No
- Other Requirements: SpecSure® system performance warranty confirms that British Gypsum proprietary systems will perform as specified for the lifetime of the building. The SpecSure® warranty requires that all components are specified in full and constructed in accordance with British Gypsum’s installation guidance. For more details see the British Gypsum website. Always check with the design team before making any changes to the chosen specification, ensuring appropriate substantiation is sought to confirm that the solution still meets all required project performances.
- Minimum Cavity / Offset (mm): 3 mm
- Fixing Method: Apply 25mm dia. blobs of sealant to the background or back of the thermal laminate in five vertical rows at 300mm centres in each row. Ensure that the blobs adjacent to a board joint are approximately 25mm in from the edge to avoid bridging the joint.
- Framework / Lining: One Side
- Parge Coat: If required apply a parge coat at least 6mm thick to the entire surface of the background ensuring all cracked or unfilled joints are covered. Allow to set before following on with plasterboard installation.
- Secondary Fixing: Fix thermal laminates to the background using two nailable plugs per laminate located at mid-point in height, 15mm from each vertical edge. Ensure plugs penetrate at least 25mm into the background excluding the thickness of any existing plaster finishes. Drive nail heads slightly below the paper surface; do not break paper or gypsum core. For thermal laminates to receive ceramic finishes, use a total of nine nailable plugs per board.
Documents
Need CAD, BIM, Test Reports and Technical Specifications?
Log in to access CAD .dwg files.
Log in and add a System Specification to a Project to access BIM files, Test Reports, and Technical Specification files.