Wall Linings
Our versatile specifications cater for a range of wall and roof constructions, including-metal frame and traditional masonry.
We cover all wall lining applications, from high-performance solutions that meet thermal, acoustic, fire-protection or impact-resistance requirements.
Linings can be fully or partially independent of the structure, or can simply be bonded or plastered directly to a wall surface. These systems can be used in all types of buildings and are equally suited to both new-build and refurbishment work.
Please note that all British Gypsum Drylining systems are tested to the BS EN fire test standard. However we can continue to support your BS Standard Specifications project with remaining test evidence to BS 476. Please click here for more information.
Watch this short video to see how to use this EN Specification Selector and where you can still get details of our BS Specifications.
- Gyproc FireLine 12.5mm (18)
- Gyproc FireLine 15mm (18)
- Gyproc FireLine MR 12.5mm (12)
- Gyproc FireLine MR 15mm (12)
- Gyproc Moisture Resistant 12.5mm (6)
- Gyproc Moisture Resistant 15mm (6)
- Gyproc SoundBloc 12.5mm (21)
- Gyproc SoundBloc 15mm (12)
- Gyproc SoundBloc MR 12.5mm (13)
- Gyproc SoundBloc MR 15mm (6)
- British Gypsum Drywall Screws 25mm (46)
- British Gypsum Drywall Screws 35mm (16)
- British Gypsum Drywall Screws 40mm (12)
- British Gypsum Drywall Screws 50mm (3)
- British Gypsum Drywall Screws 65mm (3)
- British Gypsum Drywall Screws 75mm (3)
- British Gypsum Drywall Screws 90mm (3)
- British Gypsum Drywall Screws 105mm (3)
- British Gypsum Jack-Point Screws 25mm (64)
- British Gypsum Jack-Point Screws 35mm (24)
- British Gypsum Jack-Point Screws 41mm (24)
- British Gypsum Jack-Point Screws 60mm (6)
- Gypframe 50 FEC 50 Folded Edge Standard Floor & Ceiling Channel (21)
- Gypframe 62 FEC 50 Folded Edge Standard Floor & Ceiling Channel (38)
- Gypframe 72 FEC 50 Folded Edge Standard Floor & Ceiling Channel (17)
- Gypframe 94 DC 60 Deep Flange Floor & Ceiling Channel (1)
- Gypframe 94 FEC 50 Folded Edge Standard Floor & Ceiling Channel (17)
- Gypframe 148 DC 60 Deep Flange Floor & Ceiling Channel (1)
- Gypframe 148 FEC 50 Folded Edge Standard Floor & Ceiling Channel (17)
- Gypframe GL1 Lining Channel (19)
- Gypframe GL2 Bracket (15)
- Gypframe GL3 Channel Connector (19)
- Gypframe GL8 Track (19)
- Gypframe GL9 Bracket (4)
- Gypframe GL11 GypLyner Anchor (19)
B216003 (A) (EN)
Two layers of Gyproc WallBoard 12.5mm to one side of Gypframe 48 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 2700mm.
B216003 (A) MR1 (EN)
Inner layer of Gyproc WallBoard 12.5mm with an outer layer of Gyproc Moisture Resistant 12.5mm to one side of Gypframe 48 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 2700mm.
B216003 (B) (EN)
Two layers of Gyproc WallBoard 12.5mm to one side of Gypframe 60 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3000mm.
B216003 (B) MR1 (EN)
Inner layer of Gyproc WallBoard 12.5mm with an outer layer of Gyproc Moisture Resistant 12.5mm to one side of Gypframe 60 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3000mm.
B216003 (C) (EN)
Two layers of Gyproc WallBoard 12.5mm to one side of Gypframe 60 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3600mm.
B216003 (C) MR1 (EN)
Inner layer of Gyproc WallBoard 12.5mm with an outer layer of Gyproc Moisture Resistant 12.5mm to one side of Gypframe 60 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3600mm.
B216003 (D) (EN)
Two layers of Gyproc WallBoard 12.5mm to one side of Gypframe 70 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.
B216003 (D) MR1 (EN)
Inner layer of Gyproc WallBoard 12.5mm with an outer layer of Gyproc Moisture Resistant 12.5mm to one side of Gypframe 70 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.
B216003 (E) (EN)
Two layers of Gyproc WallBoard 12.5mm to one side of Gypframe 92 I 90 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.