Wall Linings
Our versatile specifications cater for a range of wall and roof constructions, including-metal frame and traditional masonry.
We cover all wall lining applications, from high-performance solutions that meet thermal, acoustic, fire-protection or impact-resistance requirements.
Linings can be fully or partially independent of the structure, or can simply be bonded or plastered directly to a wall surface. These systems can be used in all types of buildings and are equally suited to both new-build and refurbishment work.
Please note that all British Gypsum Drylining systems are tested to the BS EN fire test standard. However we can continue to support your BS Standard Specifications project with remaining test evidence to BS 476. Please click here for more information.
Watch this short video to see how to use this EN Specification Selector and where you can still get details of our BS Specifications.
- British Gypsum Drywall Screws 25mm (16)
- British Gypsum Drywall Screws 35mm (6)
- British Gypsum Drywall Screws 40mm (6)
- British Gypsum Drywall Screws 50mm (1)
- British Gypsum Drywall Screws 65mm (1)
- British Gypsum Drywall Screws 75mm (1)
- British Gypsum Drywall Screws 90mm (1)
- British Gypsum Drywall Screws 105mm (1)
B216003 (A) (EN)
Two layers of Gyproc WallBoard 12.5mm to one side of Gypframe 48 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 2700mm.
B216003 (A) MR1 (EN)
Inner layer of Gyproc WallBoard 12.5mm with an outer layer of Gyproc Moisture Resistant 12.5mm to one side of Gypframe 48 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 2700mm.
B216004 (A) (EN)
Two layers of Gyproc WallBoard 15mm to one side of Gypframe 48 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 2800mm.
B216004 (A) MR1 (EN)
Inner layer of Gyproc WallBoard 15mm with an outer layer of Gyproc Moisture Resistant 15mm to one side of Gypframe 48 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 2800mm.
B216005 (A) (EN)
Two layers of Gyproc SoundBloc 12.5mm to one side of Gypframe 48 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 2700mm.
B216005 (A) MR1 (EN)
Inner layer of Gyproc SoundBloc 12.5mm with an outer layer of Gyproc SoundBloc MR 12.5mm to one side of Gypframe 48 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 2700mm.
B216006 (A) (EN)
Two layers of Gyproc SoundBloc 15mm to one side of Gypframe 48 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 2800mm.
B216006 (A) MR1 (EN)
Inner layer of Gyproc SoundBloc 15mm with an outer layer of Gyproc SoundBloc MR 15mm to one side of Gypframe 48 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 2800mm.
B216025 (A) (EN)
One layer of Gyproc FireLine 12.5mm to one side of Gypframe 48 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 2400mm.
-