!*
Skip to main content
toggle menu
Home
User account menu
  • Products
  • White Book Specification Selector
  • Log in / Register
Main navigation
  • Inspiration
    Building Better
    • Project Showcase
    Learn more
    Thought Leadership
    • Thought Leadership Articles
    • Thought Leaders
    Learn more
    The Build Better Centre
    Learn more
  • Specification
    White Book Specification Selector
    • White Book Overview
    • Ceilings
    • External Walls
    • Floors
    • Horizontal ShaftWall
    • Internal Partitions & Walls
    • Shaftwall
    • Steel Protection
    • Thistle Plaster Systems
    • Wall Linings
    • BS Specifications
      Display in two columns
      Off
    Learn more
    Our Products
    • Acoustic ceiling systems
    • British Gypsum fixings
    • Gypframe
    • Gyproc jointing products
    • Gyproc plasterboards
    • Thistle plasters
    Learn more
    Resources and Literature
    • All literature
    • Declaration of Performance
    • Product Data Sheets
    • Safety Data Sheets
    • Environmental Product Declarations
    Learn more
    SpecSure® System Warranty
    Learn more
  • Installation
    Our Products
    • Acoustic ceiling systems
    • British Gypsum fixings
    • Gypframe
    • Gyproc jointing products
    • Gyproc plasterboards
    • Thistle plasters
    Learn more
    The Plasterer’s Hub
    • Join the Certified Plasterer Scheme
    • Find a Certified Plasterer
    Learn more
    Installation Guidance and Support
    • Installation Guides
    • Product, project and training support
    Learn more
    Stockist Locator
    Learn more
  • Skills Development
    Upskilling Courses
    • Book a course
    • Training Prospectus
      Display in two columns
      Off
      Background color
      Grey
    • Training Academies
    Learn more
    Students, Apprentices and New Trainees
    • Partnership Colleges
    • Students and Apprentices
    Learn more
    E-Learning
    • Our Platform and Courses
    Learn more
  • Technical Support
    Self Help Tools
    • FAQs
    • Plaster Coverage Calculator
    • Thermal Calculator
    • Design Guidance
    • Resources and Literature
    Learn more
    Technical Consultancy
    • Technical Enquiry Form
    Learn more
    SpecSure® System Warranty
    Learn more
  • Customer Services
    Services
    • Distribution Innovation
    • Track and Trace
    Learn more
Search
Breadcrumb
  1. Home
  2. Specification
  3. White Book Specification Selector
  4. Wall Linings
  5. DriLyner Dab
  6. BASIC (E) (EN)
Help menu
Last reviewed:
21.09.2021
Last updated:
21.09.2021
Share
Email Facebook Twitter Linkedin
Print
Bookmark this page
Download
DriLyner Dab

BASIC (E) (EN)

One layer of Gyproc SoundBloc 12.5mm on Gyproc DriWall Adhesive dabs (10mm nominal cavity) on solid masonry background

Read more
Read less
Add to project
BASIC (E) (EN)
Share
Email Facebook Twitter Linkedin
Print
Add to project
  • Description
  • Standards
  • Products
  • Details
  • Documents
  • Test Reports
  • Installation
  • Related Case Studies

Standards

Standards Standard types
Standards Standard types

Products

Fixing method Gyproc DriWall Adhesive
Thermal sealant Gyproc DriWall Adhesive
Board side 1 Layer 1: Gyproc SoundBloc 12.5mm
Parge coat Gyproc SoundCoat Plus

Details

This section should be read in conjunction with the Products list.

  • Background: Masonry
  • Finishing Requirements: The system should be finished using either one of our Thistle or ThistlePro plasters, or Gyproc jointing products. See the product range guides on the British Gypsum website for more information.
  • Loadbearing: No
  • Other Requirements: SpecSure® system performance warranty confirms that British Gypsum proprietary systems will perform as specified for the lifetime of the building. The SpecSure® warranty requires that all components are specified in full and constructed in accordance with British Gypsum’s installation guidance. For more details see the British Gypsum website. Always check with the design team before making any changes to the chosen specification, ensuring appropriate substantiation is sought to confirm that the solution still meets all required project performances.
  • Sealant: Locate sealant at junctions with adjoining structure and other air paths. Apply as a continuous bead to clean, dry, dust-free surfaces, leaving no gaps. After application of sealant, bulk fill gaps between floor and underside of plasterboard using Gyproc jointing compound.
  • Minimum Cavity / Offset (mm): 10 mm
  • Fixing Method: Apply dabs of adhesive to the background for one board at a time, to achieve at least 20% contact with the surface area of the boards. One row of horizontal dabs to coincide with the top edge of each board. One continuous line of horizontal dabs to coincide with the bottom edge of each board. One row of vertical dabs to coincide with the side edges of each board, and additional vertical row(s) at 600mm maximum centres for boards 12.5mm thick x 1200mm wide and 450mm maximum centres for boards 12.5mm thick x 900mm wide. Ensure dabs are at least 25mm from board edges. For linings to receive ceramic finishes, apply one additional row of dabs at mid storey height.
  • Framework / Lining: One Side
  • Parge Coat: If required apply a parge coat at least 6mm thick to the entire surface of the background ensuring all cracked or unfilled joints are covered. Allow to set before following on with plasterboard installation.
  • Thermal Sealant: Before/during installation of dry lining system, fully seal all airpaths around the perimeter of the background and around structural openings and service penetrations through the background using adhesive. Apply as a continuous fillet, leaving no gaps.

Documents

Select all
CAD details (PDF)
1 datasheet related with the system
1 datasheet related with the system
British-Gypsum-DriLyner-Dab-DAPB-Dab-Board-Set.pdf
.pdf | 795.84 KB
View
Download
Certificates
1 datasheet related with the system
1 datasheet related with the system
BSI - BES 6001
.pdf | 772.38 KB
View
Download
Declaration Of Performance (DoP)
5 datasheets related with the system
5 datasheets related with the system
DoP - ADV100 - Gyproc DriWall Adhesive
.pdf | 127.29 KB
View
Download
DoP - BOARD109 - Gyproc SoundBloc
.pdf | 159.06 KB
View
Download
DoP - BOARD109 UK - Gyproc SoundBloc
.pdf | 108.88 KB
View
Download
DoP - PLAST103 - Gyproc SoundCoat Plus
.pdf | 121.38 KB
View
Download
DoP - PLAST103 UK - Gyproc SoundCoat Plus
.pdf | 91.88 KB
View
Download
Installation Guide
2 datasheets related with the system
2 datasheets related with the system
Installation Guide - Gyproc DriWall Adhesive
.pdf | 102.46 KB
View
Download
Installation Guide - Gyproc SoundCoat Plus
.pdf | 98.88 KB
View
Download
Product Data Sheet (PDS)
3 datasheets related with the system
3 datasheets related with the system
PDS - Gyproc DriWall Adhesive
.pdf | 229.94 KB
View
Download
PDS - Gyproc SoundBloc 12.5mm
.pdf | 195.52 KB
View
Download
PDS - Gyproc SoundCoat Plus
.pdf | 192.44 KB
View
Download
Safety Data Sheet (SDS)
3 datasheets related with the system
3 datasheets related with the system
SDS - Gyproc DriWall Adhesive
.pdf | 498.39 KB
View
Download
SDS - Gyproc SoundBloc
.pdf | 470.02 KB
View
Download
SDS - Gyproc SoundCoat Plus
.pdf | 489.33 KB
View
Download
Product selector guide
1 datasheet related with the system
1 datasheet related with the system
Selector Guide - Plasterboard
.pdf | 667.77 KB
View
Download
CAD details (.dwg)
3 datasheets related with the system
3 datasheets related with the system
ST-221-DAPB-01-base-head-and-corners.dwg
.dwg | 95.63 KB
ST-221-DAPB-02-ptn-abutment-window-reveal-and-door-jamb.dwg
.dwg | 106.29 KB
ST-221-DAPB-03-wall-elevation.dwg
.dwg | 58.37 KB
White Book
3 datasheets related with the system
3 datasheets related with the system
White Book - DriLyner Dab
.pdf | 5.95 MB
View
Download
White Book - Finishes
.pdf | 18.28 MB
View
Download
White Book - System design principles
.pdf | 3.59 MB
View
Download

If you require previous versions of the documentation related to the products that make up this specification, please click here

Need CAD, BIM, Test Reports and Technical Specifications?

Log in to access CAD .dwg files.

Log in and add a System Specification to a Project to access BIM files, Test Reports, and Technical Specification files.

login

Test Reports

Please add this Specification to a project and go to that Project to access the related Test Reports.

Test report label Test report name
Test report label Test report name
Image
The White Book Specification Selector
Find system specifications that match your needs
Show all specifications
British Gypsum UK

SpecSure

A unique warranty that confirms British Gypsum proprietary systems will perform as specified for the lifetime of the building.

Learn more
Facebook
Twitter
Youtube
LinkedIn
Instagram
Footer left menu
  • About Us
  • Sustainability
  • Building Better Communities
  • Corporate Governance
  • Careers
  • Cookie Policy
  • Privacy Policy
Saint-Gobain

Saint-Gobain Construction Products UK Limited trading as British Gypsum. Registered Office Saint-Gobain House, East Leake, Loughborough, Leicestershire. LE12 6JU.
Company Number 00734396. VAT No: GB 438 3065 50

© Saint-Gobain Construction Products UK Limited 2022. All rights reserved.

  • Product
  • Specification
Compare
Export the list in .csv
Compare