GCMF-1L-WB12
GypCeiling MF suspended ceiling fixed to a structural soffit and lined with one layer of Gyproc WallBoard 12.5mm, forming a lining where there is no requirement to satisfy any performance criteria.
Read more
Read less
Products
| Primary framework | Gypframe MF7 Primary Support Channel |
| Suspension type (alternative) | Gypframe FEA1 Steel Angle |
| Perimeter framing | Gypframe MF6 Perimeter Channel |
| Secondary framework | Gypframe MF5 Ceiling Section |
| Framework fixing | British Gypsum Wafer Head Jack-Point Screws 13mm |
| Suspension fixing | British Gypsum Wafer Head Jack-Point Screws 13mm Gypframe MF11 Nut and Bolt |
| Ceiling screws | Layer 1: British Gypsum Drywall Screws 25mm |
| Ceiling board | Layer 1: Gyproc WallBoard 12.5mm |
| Soffit connection | Gypframe MF12 Soffit Cleat |
| Suspension type | Gypframe MF8 Strap Hanger |
| Framework fixing (alternative) | Gypframe MF9 Connecting Clip |
| Sealant | Gyproc Sealant |
Details
This section should be read in conjunction with the Products list.
- Framework Fixing: Ceiling sections fixed to primary framework using wafer head screws or clips.
- Finishing Requirements: Finishing is not required to achieve the specified performance, but the system can be finished using either one of our Thistle or ThistlePro plasters, or Gyproc jointing products. See the product range guides on the British Gypsum website for more information.
- Loadbearing: No
- Maximum Ceiling Load (kg/m2): 30 kg/m²
- Perimeter Framing: Perimeter channel suitably fixed to background at 600mm centres.
- Screw: Fix ceiling boards securely to all supports at maximum 230mm centres (reduced to 150mm at board ends and at ceiling perimeters). Fix working from the centre of each board. Position screws not less than 13mm from cut edges and 10mm from bound edges of boards. Set screw heads flush with plasterboard surface; do not break paper or gypsum core.
- Sealant: Locate sealant at junctions with adjoining structure and other air paths. Apply as a continuous bead to clean, dry, dust-free surfaces, leaving no gaps.
- Structural Background: Suitable structural background.
- Approx. Weight (kg/m2): 9 kg/m²
- Maximum Cavity / Plenum (mm): 5600 mm
- Minimum Cavity / Plenum (mm): 150 mm
- Primary Framework Centres (mm): 1200 mm
- Secondary Framework Centres (mm): 450 mm
- Suspension Type: Strap hanger should be used for suspension up to 1000mm. Steel angle section can be used up to 5600mm.
- Suspension Type Centres (mm): 1200 mm