Ceilings
Full range of specifications from simple plasterboard ceilings through to a range of gypsum-based, acoustic suspended ceilings and lay-in grid systems
These specifications cover all building categories in both new-build and refurbishment and can satisfy the most exacting performance requirements. British Gypsum plasterboard ceilings can also be specified as a membrane to protect roof trusses in loft spaces.
Please note that all British Gypsum Drylining systems are tested to the BS EN fire test standard. However we can continue to support your BS Standard Specifications project with remaining test evidence to BS 476. Please click here for more information.
Watch this short video to see how to use this EN Specification Selector and where you can still get details of our BS Specifications.
- CasoLine Quick-Lock Grid Cross Tee (600) 15/38 (2)
- CasoLine Quick-Lock Grid Cross Tee (600) 24/38 (2)
- CasoLine Quick-Lock Grid Cross Tee (1200) 15/38 (4)
- CasoLine Quick-Lock Grid Cross Tee (1200) 24/38 (4)
- CasoLine Quick-Lock Grid Hangers (8)
- CasoLine Quick-Lock Grid Main Tee 15/38 (4)
- CasoLine Quick-Lock Grid Main Tee 24/38 (4)
- CasoLine Quick-Lock Grid Wall Angle WA02 (4)
- CasoLine Quick-Lock Grid Wall Angle WA03 (8)
- Gypframe GL1 Lining Channel (25)
- Gypframe GL2 Bracket (13)
- Gypframe GL3 Channel Connector (25)
- Gypframe GL6 Timber Connector (4)
- Gypframe GL8 Track (25)
- Gypframe GL9 Bracket (4)
- Gypframe GL12 GypLyner Bracket (4)
- Gypframe MF5 Ceiling Section (56)
- Gypframe MF6 Perimeter Channel (56)
- Gypframe MF7 Primary Support Channel (56)
- Gypframe MF8 Strap Hanger (40)
- Gypframe MF9 Connecting Clip (38)
- Gypframe MF11 Nut and Bolt (42)
- Gypframe MF12 Soffit Cleat (58)
C10A061 (EN)
GypCeiling MF suspended ceiling fixed to concrete structure to give a 200mm plenum depth and lined with one layer of Rigitone 10/23 and 50mm Isover Timber Frame Batt 32 in the plenum.
C10A062 (EN)
GypCeiling MF suspended ceiling fixed to concrete structure to give a 200mm plenum depth and lined with one layer of Rigitone 15/30 and 50mm Isover Timber Frame Batt 32 in the plenum.
C10A063 (EN)
GypCeiling MF suspended ceiling fixed to concrete structure to give a 200mm plenum depth and lined with one layer of Rigitone 12-20/66 and 50mm Isover Timber Frame Batt 32 in the plenum.
C10A069 (EN)
GypCeiling MF suspended ceiling fixed to concrete structure to give a 200mm plenum depth and lined with one layer of Rigitone 8-15-20 Super and 50mm Isover Timber Frame Batt 32 in the plenum.
C10A091 (EN)
GypCeiling MF suspended ceiling fixed to concrete structure to give a 187mm plenum depth and lined with one layer of Gyptone Quattro 41.
C10A110 (EN)
GypCeiling Lining suspended ceiling fixed to concrete structure to give a 50mm plenum depth and lined with one layer of Gyptone Quattro 42.
C10A115 (EN)
GypCeiling MF suspended ceiling fixed to concrete structure to give a 200mm plenum depth and lined with one layer of Gyptone Sixto 63.
C10A124 (EN)
GypCeiling MF suspended ceiling fixed to concrete structure to give a 200mm plenum depth and lined with one layer of Rigitone 8/18 Q.
C10A125 (EN)
GypCeiling Lining suspended ceiling fixed to concrete structure to give a 50mm plenum depth and lined with one layer of Rigitone 8/18 Q.
-
First page
-
Previous page
- …
- Page 3
- Page 4
- Page 5
- Page 6
- Page 7
- Page 8 of 10
- Current page 8
- Page 9
- Page 10
-
Next page
-