Menu

Find by System Reference

Instant access to specifications from a system reference number

Please enter the system reference below (all references are listed in the relevant White Book performance tables) and press 'Show results'. You will then be given the option to view the relevant specifications.

Export results as .csv
System System Ref Structural soffit Cavity / Plenum (mm) Ceiling board type Isover insulation Edge profile Fire Integrity (mins) Fire Insulation (mins) Sound Insulation (Airborne)
Rw dB
Rw + Ctr dB Sound Insulation (Impact) Lnw dB Sound Absorption class Coefficient αw Go to basket
Base33P (C)
Concrete
200
Gyptone Base 33 Plank 1200 E24/B
N/A
E24/B
N/A
N/A
N/A
N/A
N/A
N/A
N/A

close
CasoLine Quick-Lock Corridor System

CasoLine Quick-Lock Corridor

A corridor ceiling system that combines acoustics, aesthetics and accessibility.

CasoLine Quick-Lock Corridor system provides the ideal solution for corridor ceilings. It combines the aesthetics and sound absorption qualities of Gyptone Plank with easy access to services concealed within its plenum. It is quick and simple to install, and provides a demountable system that is easy to remove, replace and even reposition if required.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close CasoLine Quick-Lock Corridor System

CasoLine Quick-Lock Corridor

A corridor ceiling system that combines acoustics, aesthetics and accessibility.

CasoLine Quick-Lock Corridor system provides the ideal solution for corridor ceilings. It combines the aesthetics and sound absorption qualities of Gyptone Plank with easy access to services concealed within its plenum. It is quick and simple to install, and provides a demountable system that is easy to remove, replace and even reposition if required.

  • Gyptone planks and CasoLine Quick-Lock can be easily removed by hand, providing total uninterrupted access to the services above for future maintenance
  • Suspended ceilings are usually prone to damage in frequently accessed service areas as they cannot normally be easily removed. CasoLine Quick-Lock Corridor provides easy access to plenum services within corridors, through a completely un-suspended grid that can span up to 2.4m
  • There is no requirement to install hangers or soffit supports for spans 2.4m or less (1.8m if insulation laid on back); making setting out, installation and removal much easier
Base33P (C) (EN)
Concrete
200
Gyptone Base 33 Plank 1200 E24/B
N/A
E24/B
N/A
N/A
N/A
N/A
N/A
N/A
N/A

close
CasoLine Quick-Lock Corridor System

CasoLine Quick-Lock Corridor

A corridor ceiling system that combines acoustics, aesthetics and accessibility.

CasoLine Quick-Lock Corridor system provides the ideal solution for corridor ceilings. It combines the aesthetics and sound absorption qualities of Gyptone Plank with easy access to services concealed within its plenum. It is quick and simple to install, and provides a demountable system that is easy to remove, replace and even reposition if required.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close CasoLine Quick-Lock Corridor System

CasoLine Quick-Lock Corridor

A corridor ceiling system that combines acoustics, aesthetics and accessibility.

CasoLine Quick-Lock Corridor system provides the ideal solution for corridor ceilings. It combines the aesthetics and sound absorption qualities of Gyptone Plank with easy access to services concealed within its plenum. It is quick and simple to install, and provides a demountable system that is easy to remove, replace and even reposition if required.

  • Gyptone planks and CasoLine Quick-Lock can be easily removed by hand, providing total uninterrupted access to the services above for future maintenance
  • Suspended ceilings are usually prone to damage in frequently accessed service areas as they cannot normally be easily removed. CasoLine Quick-Lock Corridor provides easy access to plenum services within corridors, through a completely un-suspended grid that can span up to 2.4m
  • There is no requirement to install hangers or soffit supports for spans 2.4m or less (1.8m if insulation laid on back); making setting out, installation and removal much easier
Base33P (D)
Concrete
200
Gyptone Base 33 Plank 1800 E24/B
N/A
E24/B
N/A
N/A
N/A
N/A
N/A
N/A
N/A

close
CasoLine Quick-Lock Corridor System

CasoLine Quick-Lock Corridor

A corridor ceiling system that combines acoustics, aesthetics and accessibility.

CasoLine Quick-Lock Corridor system provides the ideal solution for corridor ceilings. It combines the aesthetics and sound absorption qualities of Gyptone Plank with easy access to services concealed within its plenum. It is quick and simple to install, and provides a demountable system that is easy to remove, replace and even reposition if required.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close CasoLine Quick-Lock Corridor System

CasoLine Quick-Lock Corridor

A corridor ceiling system that combines acoustics, aesthetics and accessibility.

CasoLine Quick-Lock Corridor system provides the ideal solution for corridor ceilings. It combines the aesthetics and sound absorption qualities of Gyptone Plank with easy access to services concealed within its plenum. It is quick and simple to install, and provides a demountable system that is easy to remove, replace and even reposition if required.

  • Gyptone planks and CasoLine Quick-Lock can be easily removed by hand, providing total uninterrupted access to the services above for future maintenance
  • Suspended ceilings are usually prone to damage in frequently accessed service areas as they cannot normally be easily removed. CasoLine Quick-Lock Corridor provides easy access to plenum services within corridors, through a completely un-suspended grid that can span up to 2.4m
  • There is no requirement to install hangers or soffit supports for spans 2.4m or less (1.8m if insulation laid on back); making setting out, installation and removal much easier
Base33P (D) (EN)
Concrete
200
Gyptone Base 33 Plank 1800 E24/B
N/A
E24/B
N/A
N/A
N/A
N/A
N/A
N/A
N/A

close
CasoLine Quick-Lock Corridor System

CasoLine Quick-Lock Corridor

A corridor ceiling system that combines acoustics, aesthetics and accessibility.

CasoLine Quick-Lock Corridor system provides the ideal solution for corridor ceilings. It combines the aesthetics and sound absorption qualities of Gyptone Plank with easy access to services concealed within its plenum. It is quick and simple to install, and provides a demountable system that is easy to remove, replace and even reposition if required.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close CasoLine Quick-Lock Corridor System

CasoLine Quick-Lock Corridor

A corridor ceiling system that combines acoustics, aesthetics and accessibility.

CasoLine Quick-Lock Corridor system provides the ideal solution for corridor ceilings. It combines the aesthetics and sound absorption qualities of Gyptone Plank with easy access to services concealed within its plenum. It is quick and simple to install, and provides a demountable system that is easy to remove, replace and even reposition if required.

  • Gyptone planks and CasoLine Quick-Lock can be easily removed by hand, providing total uninterrupted access to the services above for future maintenance
  • Suspended ceilings are usually prone to damage in frequently accessed service areas as they cannot normally be easily removed. CasoLine Quick-Lock Corridor provides easy access to plenum services within corridors, through a completely un-suspended grid that can span up to 2.4m
  • There is no requirement to install hangers or soffit supports for spans 2.4m or less (1.8m if insulation laid on back); making setting out, installation and removal much easier
Base33P (E)
Concrete
200
Gyptone Base 33 Plank 2400 E24/B
N/A
E24/B
N/A
N/A
N/A
N/A
N/A
N/A
N/A

close
CasoLine Quick-Lock Corridor System

CasoLine Quick-Lock Corridor

A corridor ceiling system that combines acoustics, aesthetics and accessibility.

CasoLine Quick-Lock Corridor system provides the ideal solution for corridor ceilings. It combines the aesthetics and sound absorption qualities of Gyptone Plank with easy access to services concealed within its plenum. It is quick and simple to install, and provides a demountable system that is easy to remove, replace and even reposition if required.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close CasoLine Quick-Lock Corridor System

CasoLine Quick-Lock Corridor

A corridor ceiling system that combines acoustics, aesthetics and accessibility.

CasoLine Quick-Lock Corridor system provides the ideal solution for corridor ceilings. It combines the aesthetics and sound absorption qualities of Gyptone Plank with easy access to services concealed within its plenum. It is quick and simple to install, and provides a demountable system that is easy to remove, replace and even reposition if required.

  • Gyptone planks and CasoLine Quick-Lock can be easily removed by hand, providing total uninterrupted access to the services above for future maintenance
  • Suspended ceilings are usually prone to damage in frequently accessed service areas as they cannot normally be easily removed. CasoLine Quick-Lock Corridor provides easy access to plenum services within corridors, through a completely un-suspended grid that can span up to 2.4m
  • There is no requirement to install hangers or soffit supports for spans 2.4m or less (1.8m if insulation laid on back); making setting out, installation and removal much easier
Base33P (E) (EN)
Concrete
200
Gyptone Base 33 Plank 2400 E24/B
N/A
E24/B
N/A
N/A
N/A
N/A
N/A
N/A
N/A

close
CasoLine Quick-Lock Corridor System

CasoLine Quick-Lock Corridor

A corridor ceiling system that combines acoustics, aesthetics and accessibility.

CasoLine Quick-Lock Corridor system provides the ideal solution for corridor ceilings. It combines the aesthetics and sound absorption qualities of Gyptone Plank with easy access to services concealed within its plenum. It is quick and simple to install, and provides a demountable system that is easy to remove, replace and even reposition if required.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close CasoLine Quick-Lock Corridor System

CasoLine Quick-Lock Corridor

A corridor ceiling system that combines acoustics, aesthetics and accessibility.

CasoLine Quick-Lock Corridor system provides the ideal solution for corridor ceilings. It combines the aesthetics and sound absorption qualities of Gyptone Plank with easy access to services concealed within its plenum. It is quick and simple to install, and provides a demountable system that is easy to remove, replace and even reposition if required.

  • Gyptone planks and CasoLine Quick-Lock can be easily removed by hand, providing total uninterrupted access to the services above for future maintenance
  • Suspended ceilings are usually prone to damage in frequently accessed service areas as they cannot normally be easily removed. CasoLine Quick-Lock Corridor provides easy access to plenum services within corridors, through a completely un-suspended grid that can span up to 2.4m
  • There is no requirement to install hangers or soffit supports for spans 2.4m or less (1.8m if insulation laid on back); making setting out, installation and removal much easier
C100013
Concrete floors
75 - 5600
Gyproc WallBoard (2 x 12.5)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

close
CasoLine MF

CasoLine MF

Concealed monolithic metal frame suspended ceiling system.

CasoLine MF is a suspended ceiling system suitable for most internal drylining applications. The fully concealed grid and ceiling lining can be used in conjunction with Gyproc plasterboards and Gyptone and Rigitone acoustic ceiling boards to create a seamless, monolithic appearance.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close CasoLine MF

CasoLine MF

Concealed monolithic metal frame suspended ceiling system.

CasoLine MF is a suspended ceiling system suitable for most internal drylining applications. The fully concealed grid and ceiling lining can be used in conjunction with Gyproc plasterboards and Gyptone and Rigitone acoustic ceiling boards to create a seamless, monolithic appearance.

  • High level of design flexibility; bulkheads, gradients and changes in height can all be fully integrated
  • Services inspection and access points are easily included during design or installation
  • Adaptable metal framing system fully compatible with a wide range of British Gypsum lining solutions to achieve a variety of performances tailored to meet individual project requirements
  • Improvement to acoustic and fire performance can be achieved without the need to access the room above
  • Partition heights can be reduced as the partition channel can be supported by the ceiling framework rather than the soffit

How do I get a 30 minute fire protection to structural steel beams supporting a concrete floor from a lay in suspended ceiling?

Our Gyprex Satinspar tiles are all capable of achieving 30-minute fire protection to BS476-Pt 23: 1987 if installed in specific CasoLine lay-in grid systems.

How do you upgrade the fire and/or acoustic performance of a timber floor from below?

We offer a wide range of ceiling systems for this purpose including GypLyner UNIVERSAL and CasoLine MF.

How To - Install CasoLine MF

C100014
Concrete floors
75 - 5600
Gyproc FireLine (12.5)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

close
CasoLine MF

CasoLine MF

Concealed monolithic metal frame suspended ceiling system.

CasoLine MF is a suspended ceiling system suitable for most internal drylining applications. The fully concealed grid and ceiling lining can be used in conjunction with Gyproc plasterboards and Gyptone and Rigitone acoustic ceiling boards to create a seamless, monolithic appearance.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close CasoLine MF

CasoLine MF

Concealed monolithic metal frame suspended ceiling system.

CasoLine MF is a suspended ceiling system suitable for most internal drylining applications. The fully concealed grid and ceiling lining can be used in conjunction with Gyproc plasterboards and Gyptone and Rigitone acoustic ceiling boards to create a seamless, monolithic appearance.

  • High level of design flexibility; bulkheads, gradients and changes in height can all be fully integrated
  • Services inspection and access points are easily included during design or installation
  • Adaptable metal framing system fully compatible with a wide range of British Gypsum lining solutions to achieve a variety of performances tailored to meet individual project requirements
  • Improvement to acoustic and fire performance can be achieved without the need to access the room above
  • Partition heights can be reduced as the partition channel can be supported by the ceiling framework rather than the soffit

How do I get a 30 minute fire protection to structural steel beams supporting a concrete floor from a lay in suspended ceiling?

Our Gyprex Satinspar tiles are all capable of achieving 30-minute fire protection to BS476-Pt 23: 1987 if installed in specific CasoLine lay-in grid systems.

How do you upgrade the fire and/or acoustic performance of a timber floor from below?

We offer a wide range of ceiling systems for this purpose including GypLyner UNIVERSAL and CasoLine MF.

How To - Install CasoLine MF

C100015
Concrete floors
75 - 5600
Gyproc FireLine (2 x 15)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

close
CasoLine MF

CasoLine MF

Concealed monolithic metal frame suspended ceiling system.

CasoLine MF is a suspended ceiling system suitable for most internal drylining applications. The fully concealed grid and ceiling lining can be used in conjunction with Gyproc plasterboards and Gyptone and Rigitone acoustic ceiling boards to create a seamless, monolithic appearance.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close CasoLine MF

CasoLine MF

Concealed monolithic metal frame suspended ceiling system.

CasoLine MF is a suspended ceiling system suitable for most internal drylining applications. The fully concealed grid and ceiling lining can be used in conjunction with Gyproc plasterboards and Gyptone and Rigitone acoustic ceiling boards to create a seamless, monolithic appearance.

  • High level of design flexibility; bulkheads, gradients and changes in height can all be fully integrated
  • Services inspection and access points are easily included during design or installation
  • Adaptable metal framing system fully compatible with a wide range of British Gypsum lining solutions to achieve a variety of performances tailored to meet individual project requirements
  • Improvement to acoustic and fire performance can be achieved without the need to access the room above
  • Partition heights can be reduced as the partition channel can be supported by the ceiling framework rather than the soffit

How do I get a 30 minute fire protection to structural steel beams supporting a concrete floor from a lay in suspended ceiling?

Our Gyprex Satinspar tiles are all capable of achieving 30-minute fire protection to BS476-Pt 23: 1987 if installed in specific CasoLine lay-in grid systems.

How do you upgrade the fire and/or acoustic performance of a timber floor from below?

We offer a wide range of ceiling systems for this purpose including GypLyner UNIVERSAL and CasoLine MF.

How To - Install CasoLine MF

C100016
150mm thick Beam & Block Floor (90kg/m2)
240 - 5600
Gyproc WallBoard (12.5)
N/A
N/A
N/A
N/A
56
50
68
N/A
N/A

close
CasoLine MF

CasoLine MF

Concealed monolithic metal frame suspended ceiling system.

CasoLine MF is a suspended ceiling system suitable for most internal drylining applications. The fully concealed grid and ceiling lining can be used in conjunction with Gyproc plasterboards and Gyptone and Rigitone acoustic ceiling boards to create a seamless, monolithic appearance.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close CasoLine MF

CasoLine MF

Concealed monolithic metal frame suspended ceiling system.

CasoLine MF is a suspended ceiling system suitable for most internal drylining applications. The fully concealed grid and ceiling lining can be used in conjunction with Gyproc plasterboards and Gyptone and Rigitone acoustic ceiling boards to create a seamless, monolithic appearance.

  • High level of design flexibility; bulkheads, gradients and changes in height can all be fully integrated
  • Services inspection and access points are easily included during design or installation
  • Adaptable metal framing system fully compatible with a wide range of British Gypsum lining solutions to achieve a variety of performances tailored to meet individual project requirements
  • Improvement to acoustic and fire performance can be achieved without the need to access the room above
  • Partition heights can be reduced as the partition channel can be supported by the ceiling framework rather than the soffit

How do I get a 30 minute fire protection to structural steel beams supporting a concrete floor from a lay in suspended ceiling?

Our Gyprex Satinspar tiles are all capable of achieving 30-minute fire protection to BS476-Pt 23: 1987 if installed in specific CasoLine lay-in grid systems.

How do you upgrade the fire and/or acoustic performance of a timber floor from below?

We offer a wide range of ceiling systems for this purpose including GypLyner UNIVERSAL and CasoLine MF.

How To - Install CasoLine MF

Export results as .csv
System System Ref Background Board type Fire Protection (mins) Section Factor A/V (HP/A) m-1 (max) Go to basket
D120001 (A)
Steel Column or Beam
Glasroc F FireCase (15)
30
260

close
FireCase

FireCase

Frameless structural steel encasement system that provides up to 120 minutes fire protection.

FireCase is a frameless structural steel encasement system that provides up to 120 minutes fire protection to a wide range of universal beam, column and joist sizes. Installation is quick and easy owing to the ability to fix Glasroc F FireCase boards to one another without the need for additional framing. The Glasroc F FireCase lining provides a smooth, robust surface with no requirement to joint or apply a decorative treatment.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close FireCase

FireCase

Frameless structural steel encasement system that provides up to 120 minutes fire protection.

FireCase is a frameless structural steel encasement system that provides up to 120 minutes fire protection to a wide range of universal beam, column and joist sizes. Installation is quick and easy owing to the ability to fix Glasroc F FireCase boards to one another without the need for additional framing. The Glasroc F FireCase lining provides a smooth, robust surface with no requirement to joint or apply a decorative treatment.

  • Frameless system that minimises the space needed to provide fire protection to structural steel
  • Reduced installation time as Glasroc F Firecase boards can be staple-fixed to one another without the need for other components
  • Build-programme flexibility and earlier installation as the inherent moisture resistance capability of Glasroc F Firecase means that installation of the FireCase system can commence before the building envelope is fully weather tight
  • FireCase system is easy to inspect for continuity when compared to intumescent paint solutions, giving greater peace of mind both immediately after installation and during maintenance inspections
  • Reduced waste and labour onsite as bespoke, pre-cut widths of Glasroc F Firecase are available (subject to minimum order quantity)
  • High levels of acoustic insulation, in addition to excellent fire protection performance, can be maintained with appropriate detailing to the abutments between GypWall partition systems and FireCase steel encasements
  • British Board of Agrément (BBA) approved (93/2935)

How do you fire protect structural steel sections?

We offer the FireCase system or the GypLyner ENCASE system to form an encasement around the beam or column.

How do you protect a steel column within a masonry wall

Our FireCase system using Glasroc F FireCase board can be used to fire protect partially exposed steel columns within a masonry wall.

How much space is required to encase steel sections?

With our FireCase frameless encasement system it could be only the Glasroc F FireCase board width itself (e.g. minimum 15mm). Our GypLyner ENCASE system requires more space due to the metal framework.

D120001 (A) (EN)
Steel Column (4 Sides)
Glasroc F FireCase (15)
30
260

close
FireCase

FireCase

Frameless structural steel encasement system that provides up to 120 minutes fire protection.

FireCase is a frameless structural steel encasement system that provides up to 120 minutes fire protection to a wide range of universal beam, column and joist sizes. Installation is quick and easy owing to the ability to fix Glasroc F FireCase boards to one another without the need for additional framing. The Glasroc F FireCase lining provides a smooth, robust surface with no requirement to joint or apply a decorative treatment.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close FireCase

FireCase

Frameless structural steel encasement system that provides up to 120 minutes fire protection.

FireCase is a frameless structural steel encasement system that provides up to 120 minutes fire protection to a wide range of universal beam, column and joist sizes. Installation is quick and easy owing to the ability to fix Glasroc F FireCase boards to one another without the need for additional framing. The Glasroc F FireCase lining provides a smooth, robust surface with no requirement to joint or apply a decorative treatment.

  • Frameless system that minimises the space needed to provide fire protection to structural steel
  • Reduced installation time as Glasroc F Firecase boards can be staple-fixed to one another without the need for other components
  • Build-programme flexibility and earlier installation as the inherent moisture resistance capability of Glasroc F Firecase means that installation of the FireCase system can commence before the building envelope is fully weather tight
  • FireCase system is easy to inspect for continuity when compared to intumescent paint solutions, giving greater peace of mind both immediately after installation and during maintenance inspections
  • Reduced waste and labour onsite as bespoke, pre-cut widths of Glasroc F Firecase are available (subject to minimum order quantity)
  • High levels of acoustic insulation, in addition to excellent fire protection performance, can be maintained with appropriate detailing to the abutments between GypWall partition systems and FireCase steel encasements
  • British Board of Agrément (BBA) approved (93/2935)

How do you fire protect structural steel sections?

We offer the FireCase system or the GypLyner ENCASE system to form an encasement around the beam or column.

How do you protect a steel column within a masonry wall

Our FireCase system using Glasroc F FireCase board can be used to fire protect partially exposed steel columns within a masonry wall.

How much space is required to encase steel sections?

With our FireCase frameless encasement system it could be only the Glasroc F FireCase board width itself (e.g. minimum 15mm). Our GypLyner ENCASE system requires more space due to the metal framework.

D120001 (B)
Steel Column or Beam
Glasroc F FireCase (15)
60
260

close
FireCase

FireCase

Frameless structural steel encasement system that provides up to 120 minutes fire protection.

FireCase is a frameless structural steel encasement system that provides up to 120 minutes fire protection to a wide range of universal beam, column and joist sizes. Installation is quick and easy owing to the ability to fix Glasroc F FireCase boards to one another without the need for additional framing. The Glasroc F FireCase lining provides a smooth, robust surface with no requirement to joint or apply a decorative treatment.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close FireCase

FireCase

Frameless structural steel encasement system that provides up to 120 minutes fire protection.

FireCase is a frameless structural steel encasement system that provides up to 120 minutes fire protection to a wide range of universal beam, column and joist sizes. Installation is quick and easy owing to the ability to fix Glasroc F FireCase boards to one another without the need for additional framing. The Glasroc F FireCase lining provides a smooth, robust surface with no requirement to joint or apply a decorative treatment.

  • Frameless system that minimises the space needed to provide fire protection to structural steel
  • Reduced installation time as Glasroc F Firecase boards can be staple-fixed to one another without the need for other components
  • Build-programme flexibility and earlier installation as the inherent moisture resistance capability of Glasroc F Firecase means that installation of the FireCase system can commence before the building envelope is fully weather tight
  • FireCase system is easy to inspect for continuity when compared to intumescent paint solutions, giving greater peace of mind both immediately after installation and during maintenance inspections
  • Reduced waste and labour onsite as bespoke, pre-cut widths of Glasroc F Firecase are available (subject to minimum order quantity)
  • High levels of acoustic insulation, in addition to excellent fire protection performance, can be maintained with appropriate detailing to the abutments between GypWall partition systems and FireCase steel encasements
  • British Board of Agrément (BBA) approved (93/2935)

How do you fire protect structural steel sections?

We offer the FireCase system or the GypLyner ENCASE system to form an encasement around the beam or column.

How do you protect a steel column within a masonry wall

Our FireCase system using Glasroc F FireCase board can be used to fire protect partially exposed steel columns within a masonry wall.

How much space is required to encase steel sections?

With our FireCase frameless encasement system it could be only the Glasroc F FireCase board width itself (e.g. minimum 15mm). Our GypLyner ENCASE system requires more space due to the metal framework.

D120001 (B) (EN)
Steel Beam (3 Sides)
Glasroc F FireCase (15)
30
260

close
FireCase

FireCase

Frameless structural steel encasement system that provides up to 120 minutes fire protection.

FireCase is a frameless structural steel encasement system that provides up to 120 minutes fire protection to a wide range of universal beam, column and joist sizes. Installation is quick and easy owing to the ability to fix Glasroc F FireCase boards to one another without the need for additional framing. The Glasroc F FireCase lining provides a smooth, robust surface with no requirement to joint or apply a decorative treatment.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close FireCase

FireCase

Frameless structural steel encasement system that provides up to 120 minutes fire protection.

FireCase is a frameless structural steel encasement system that provides up to 120 minutes fire protection to a wide range of universal beam, column and joist sizes. Installation is quick and easy owing to the ability to fix Glasroc F FireCase boards to one another without the need for additional framing. The Glasroc F FireCase lining provides a smooth, robust surface with no requirement to joint or apply a decorative treatment.

  • Frameless system that minimises the space needed to provide fire protection to structural steel
  • Reduced installation time as Glasroc F Firecase boards can be staple-fixed to one another without the need for other components
  • Build-programme flexibility and earlier installation as the inherent moisture resistance capability of Glasroc F Firecase means that installation of the FireCase system can commence before the building envelope is fully weather tight
  • FireCase system is easy to inspect for continuity when compared to intumescent paint solutions, giving greater peace of mind both immediately after installation and during maintenance inspections
  • Reduced waste and labour onsite as bespoke, pre-cut widths of Glasroc F Firecase are available (subject to minimum order quantity)
  • High levels of acoustic insulation, in addition to excellent fire protection performance, can be maintained with appropriate detailing to the abutments between GypWall partition systems and FireCase steel encasements
  • British Board of Agrément (BBA) approved (93/2935)

How do you fire protect structural steel sections?

We offer the FireCase system or the GypLyner ENCASE system to form an encasement around the beam or column.

How do you protect a steel column within a masonry wall

Our FireCase system using Glasroc F FireCase board can be used to fire protect partially exposed steel columns within a masonry wall.

How much space is required to encase steel sections?

With our FireCase frameless encasement system it could be only the Glasroc F FireCase board width itself (e.g. minimum 15mm). Our GypLyner ENCASE system requires more space due to the metal framework.

D120001 (C)
Steel Column or Beam
Glasroc F FireCase (15)
90
105

close
FireCase

FireCase

Frameless structural steel encasement system that provides up to 120 minutes fire protection.

FireCase is a frameless structural steel encasement system that provides up to 120 minutes fire protection to a wide range of universal beam, column and joist sizes. Installation is quick and easy owing to the ability to fix Glasroc F FireCase boards to one another without the need for additional framing. The Glasroc F FireCase lining provides a smooth, robust surface with no requirement to joint or apply a decorative treatment.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close FireCase

FireCase

Frameless structural steel encasement system that provides up to 120 minutes fire protection.

FireCase is a frameless structural steel encasement system that provides up to 120 minutes fire protection to a wide range of universal beam, column and joist sizes. Installation is quick and easy owing to the ability to fix Glasroc F FireCase boards to one another without the need for additional framing. The Glasroc F FireCase lining provides a smooth, robust surface with no requirement to joint or apply a decorative treatment.

  • Frameless system that minimises the space needed to provide fire protection to structural steel
  • Reduced installation time as Glasroc F Firecase boards can be staple-fixed to one another without the need for other components
  • Build-programme flexibility and earlier installation as the inherent moisture resistance capability of Glasroc F Firecase means that installation of the FireCase system can commence before the building envelope is fully weather tight
  • FireCase system is easy to inspect for continuity when compared to intumescent paint solutions, giving greater peace of mind both immediately after installation and during maintenance inspections
  • Reduced waste and labour onsite as bespoke, pre-cut widths of Glasroc F Firecase are available (subject to minimum order quantity)
  • High levels of acoustic insulation, in addition to excellent fire protection performance, can be maintained with appropriate detailing to the abutments between GypWall partition systems and FireCase steel encasements
  • British Board of Agrément (BBA) approved (93/2935)

How do you fire protect structural steel sections?

We offer the FireCase system or the GypLyner ENCASE system to form an encasement around the beam or column.

How do you protect a steel column within a masonry wall

Our FireCase system using Glasroc F FireCase board can be used to fire protect partially exposed steel columns within a masonry wall.

How much space is required to encase steel sections?

With our FireCase frameless encasement system it could be only the Glasroc F FireCase board width itself (e.g. minimum 15mm). Our GypLyner ENCASE system requires more space due to the metal framework.

D120001 (C) (EN)
Steel Column (4 Sides)
Glasroc F FireCase (15)
60
232

close
FireCase

FireCase

Frameless structural steel encasement system that provides up to 120 minutes fire protection.

FireCase is a frameless structural steel encasement system that provides up to 120 minutes fire protection to a wide range of universal beam, column and joist sizes. Installation is quick and easy owing to the ability to fix Glasroc F FireCase boards to one another without the need for additional framing. The Glasroc F FireCase lining provides a smooth, robust surface with no requirement to joint or apply a decorative treatment.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close FireCase

FireCase

Frameless structural steel encasement system that provides up to 120 minutes fire protection.

FireCase is a frameless structural steel encasement system that provides up to 120 minutes fire protection to a wide range of universal beam, column and joist sizes. Installation is quick and easy owing to the ability to fix Glasroc F FireCase boards to one another without the need for additional framing. The Glasroc F FireCase lining provides a smooth, robust surface with no requirement to joint or apply a decorative treatment.

  • Frameless system that minimises the space needed to provide fire protection to structural steel
  • Reduced installation time as Glasroc F Firecase boards can be staple-fixed to one another without the need for other components
  • Build-programme flexibility and earlier installation as the inherent moisture resistance capability of Glasroc F Firecase means that installation of the FireCase system can commence before the building envelope is fully weather tight
  • FireCase system is easy to inspect for continuity when compared to intumescent paint solutions, giving greater peace of mind both immediately after installation and during maintenance inspections
  • Reduced waste and labour onsite as bespoke, pre-cut widths of Glasroc F Firecase are available (subject to minimum order quantity)
  • High levels of acoustic insulation, in addition to excellent fire protection performance, can be maintained with appropriate detailing to the abutments between GypWall partition systems and FireCase steel encasements
  • British Board of Agrément (BBA) approved (93/2935)

How do you fire protect structural steel sections?

We offer the FireCase system or the GypLyner ENCASE system to form an encasement around the beam or column.

How do you protect a steel column within a masonry wall

Our FireCase system using Glasroc F FireCase board can be used to fire protect partially exposed steel columns within a masonry wall.

How much space is required to encase steel sections?

With our FireCase frameless encasement system it could be only the Glasroc F FireCase board width itself (e.g. minimum 15mm). Our GypLyner ENCASE system requires more space due to the metal framework.

D120001 (D)
Steel Column or Beam
Glasroc F FireCase (20)
90
180

close
FireCase

FireCase

Frameless structural steel encasement system that provides up to 120 minutes fire protection.

FireCase is a frameless structural steel encasement system that provides up to 120 minutes fire protection to a wide range of universal beam, column and joist sizes. Installation is quick and easy owing to the ability to fix Glasroc F FireCase boards to one another without the need for additional framing. The Glasroc F FireCase lining provides a smooth, robust surface with no requirement to joint or apply a decorative treatment.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close FireCase

FireCase

Frameless structural steel encasement system that provides up to 120 minutes fire protection.

FireCase is a frameless structural steel encasement system that provides up to 120 minutes fire protection to a wide range of universal beam, column and joist sizes. Installation is quick and easy owing to the ability to fix Glasroc F FireCase boards to one another without the need for additional framing. The Glasroc F FireCase lining provides a smooth, robust surface with no requirement to joint or apply a decorative treatment.

  • Frameless system that minimises the space needed to provide fire protection to structural steel
  • Reduced installation time as Glasroc F Firecase boards can be staple-fixed to one another without the need for other components
  • Build-programme flexibility and earlier installation as the inherent moisture resistance capability of Glasroc F Firecase means that installation of the FireCase system can commence before the building envelope is fully weather tight
  • FireCase system is easy to inspect for continuity when compared to intumescent paint solutions, giving greater peace of mind both immediately after installation and during maintenance inspections
  • Reduced waste and labour onsite as bespoke, pre-cut widths of Glasroc F Firecase are available (subject to minimum order quantity)
  • High levels of acoustic insulation, in addition to excellent fire protection performance, can be maintained with appropriate detailing to the abutments between GypWall partition systems and FireCase steel encasements
  • British Board of Agrément (BBA) approved (93/2935)

How do you fire protect structural steel sections?

We offer the FireCase system or the GypLyner ENCASE system to form an encasement around the beam or column.

How do you protect a steel column within a masonry wall

Our FireCase system using Glasroc F FireCase board can be used to fire protect partially exposed steel columns within a masonry wall.

How much space is required to encase steel sections?

With our FireCase frameless encasement system it could be only the Glasroc F FireCase board width itself (e.g. minimum 15mm). Our GypLyner ENCASE system requires more space due to the metal framework.

D120001 (D) (EN)
Steel Beam (3 Sides)
Glasroc F FireCase (15)
60
129

close
FireCase

FireCase

Frameless structural steel encasement system that provides up to 120 minutes fire protection.

FireCase is a frameless structural steel encasement system that provides up to 120 minutes fire protection to a wide range of universal beam, column and joist sizes. Installation is quick and easy owing to the ability to fix Glasroc F FireCase boards to one another without the need for additional framing. The Glasroc F FireCase lining provides a smooth, robust surface with no requirement to joint or apply a decorative treatment.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close FireCase

FireCase

Frameless structural steel encasement system that provides up to 120 minutes fire protection.

FireCase is a frameless structural steel encasement system that provides up to 120 minutes fire protection to a wide range of universal beam, column and joist sizes. Installation is quick and easy owing to the ability to fix Glasroc F FireCase boards to one another without the need for additional framing. The Glasroc F FireCase lining provides a smooth, robust surface with no requirement to joint or apply a decorative treatment.

  • Frameless system that minimises the space needed to provide fire protection to structural steel
  • Reduced installation time as Glasroc F Firecase boards can be staple-fixed to one another without the need for other components
  • Build-programme flexibility and earlier installation as the inherent moisture resistance capability of Glasroc F Firecase means that installation of the FireCase system can commence before the building envelope is fully weather tight
  • FireCase system is easy to inspect for continuity when compared to intumescent paint solutions, giving greater peace of mind both immediately after installation and during maintenance inspections
  • Reduced waste and labour onsite as bespoke, pre-cut widths of Glasroc F Firecase are available (subject to minimum order quantity)
  • High levels of acoustic insulation, in addition to excellent fire protection performance, can be maintained with appropriate detailing to the abutments between GypWall partition systems and FireCase steel encasements
  • British Board of Agrément (BBA) approved (93/2935)

How do you fire protect structural steel sections?

We offer the FireCase system or the GypLyner ENCASE system to form an encasement around the beam or column.

How do you protect a steel column within a masonry wall

Our FireCase system using Glasroc F FireCase board can be used to fire protect partially exposed steel columns within a masonry wall.

How much space is required to encase steel sections?

With our FireCase frameless encasement system it could be only the Glasroc F FireCase board width itself (e.g. minimum 15mm). Our GypLyner ENCASE system requires more space due to the metal framework.

D120001 (E)
Steel Column or Beam
Glasroc F FireCase (25)
90
260

close
FireCase

FireCase

Frameless structural steel encasement system that provides up to 120 minutes fire protection.

FireCase is a frameless structural steel encasement system that provides up to 120 minutes fire protection to a wide range of universal beam, column and joist sizes. Installation is quick and easy owing to the ability to fix Glasroc F FireCase boards to one another without the need for additional framing. The Glasroc F FireCase lining provides a smooth, robust surface with no requirement to joint or apply a decorative treatment.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close FireCase

FireCase

Frameless structural steel encasement system that provides up to 120 minutes fire protection.

FireCase is a frameless structural steel encasement system that provides up to 120 minutes fire protection to a wide range of universal beam, column and joist sizes. Installation is quick and easy owing to the ability to fix Glasroc F FireCase boards to one another without the need for additional framing. The Glasroc F FireCase lining provides a smooth, robust surface with no requirement to joint or apply a decorative treatment.

  • Frameless system that minimises the space needed to provide fire protection to structural steel
  • Reduced installation time as Glasroc F Firecase boards can be staple-fixed to one another without the need for other components
  • Build-programme flexibility and earlier installation as the inherent moisture resistance capability of Glasroc F Firecase means that installation of the FireCase system can commence before the building envelope is fully weather tight
  • FireCase system is easy to inspect for continuity when compared to intumescent paint solutions, giving greater peace of mind both immediately after installation and during maintenance inspections
  • Reduced waste and labour onsite as bespoke, pre-cut widths of Glasroc F Firecase are available (subject to minimum order quantity)
  • High levels of acoustic insulation, in addition to excellent fire protection performance, can be maintained with appropriate detailing to the abutments between GypWall partition systems and FireCase steel encasements
  • British Board of Agrément (BBA) approved (93/2935)

How do you fire protect structural steel sections?

We offer the FireCase system or the GypLyner ENCASE system to form an encasement around the beam or column.

How do you protect a steel column within a masonry wall

Our FireCase system using Glasroc F FireCase board can be used to fire protect partially exposed steel columns within a masonry wall.

How much space is required to encase steel sections?

With our FireCase frameless encasement system it could be only the Glasroc F FireCase board width itself (e.g. minimum 15mm). Our GypLyner ENCASE system requires more space due to the metal framework.

D120001 (E) (EN)
Steel Column (4 Sides)
Glasroc F FireCase (15)
90
98

close
FireCase

FireCase

Frameless structural steel encasement system that provides up to 120 minutes fire protection.

FireCase is a frameless structural steel encasement system that provides up to 120 minutes fire protection to a wide range of universal beam, column and joist sizes. Installation is quick and easy owing to the ability to fix Glasroc F FireCase boards to one another without the need for additional framing. The Glasroc F FireCase lining provides a smooth, robust surface with no requirement to joint or apply a decorative treatment.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close FireCase

FireCase

Frameless structural steel encasement system that provides up to 120 minutes fire protection.

FireCase is a frameless structural steel encasement system that provides up to 120 minutes fire protection to a wide range of universal beam, column and joist sizes. Installation is quick and easy owing to the ability to fix Glasroc F FireCase boards to one another without the need for additional framing. The Glasroc F FireCase lining provides a smooth, robust surface with no requirement to joint or apply a decorative treatment.

  • Frameless system that minimises the space needed to provide fire protection to structural steel
  • Reduced installation time as Glasroc F Firecase boards can be staple-fixed to one another without the need for other components
  • Build-programme flexibility and earlier installation as the inherent moisture resistance capability of Glasroc F Firecase means that installation of the FireCase system can commence before the building envelope is fully weather tight
  • FireCase system is easy to inspect for continuity when compared to intumescent paint solutions, giving greater peace of mind both immediately after installation and during maintenance inspections
  • Reduced waste and labour onsite as bespoke, pre-cut widths of Glasroc F Firecase are available (subject to minimum order quantity)
  • High levels of acoustic insulation, in addition to excellent fire protection performance, can be maintained with appropriate detailing to the abutments between GypWall partition systems and FireCase steel encasements
  • British Board of Agrément (BBA) approved (93/2935)

How do you fire protect structural steel sections?

We offer the FireCase system or the GypLyner ENCASE system to form an encasement around the beam or column.

How do you protect a steel column within a masonry wall

Our FireCase system using Glasroc F FireCase board can be used to fire protect partially exposed steel columns within a masonry wall.

How much space is required to encase steel sections?

With our FireCase frameless encasement system it could be only the Glasroc F FireCase board width itself (e.g. minimum 15mm). Our GypLyner ENCASE system requires more space due to the metal framework.

Export results as .csv
System System Ref Lower framework Lower framework boarding Upper framework Upper framework boarding System depth (mm) Max span (mm) Insulation Fire Integrity (mins) Fire Insulation (mins) Sound Insulation
Rw dB
Go to basket
C106053
Gypframe 60 I 70 'I' Stud @ 600mm centres & Gypframe MF5 Ceiling Sections @ 450mm centres
2 x 15mm Gyproc FireLine (+ 19mm Gyproc CoreBoard in cavity)
N/A
N/A
120
2500
N/A
60
60
42

close
ShaftWall

ShaftWall

Shaft and duct encasement system.

ShaftWall provides a lightweight, fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an early stage of the construction without the need for scaffolding. The system can also be built horizontally to provide a fire rated membrane.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close ShaftWall

ShaftWall

Shaft and duct encasement system.

ShaftWall provides a lightweight, fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an early stage of the construction without the need for scaffolding. The system can also be built horizontally to provide a fire rated membrane.

  • Horizontal membranes are built entirely from below
  • A ShaftWall variant with non-combustible Glasroc F FireCase board linings is available
  • High level commonality with GypWall partition components, particularly 70mm stud solutions
  • Higher certainty of installed acoustic performance due to laboratory tests incorporating deflection heads
  • Can be used where access is limited to one side at the head, e.g. M & E cages already installed in corridors

Is Gyproc FireStrip required

Where included in the detail, Gyproc FireStrip is an essential component in maintaining the fire resistance of a partition.

How do you build a fire-rated partition where access is limited to one side only?

Our ShaftWall system is designed for this application.

What are Staggered, Quiet, Quiet SF, Audio, ShaftWall stud partitions?

These are all types of British Gypsum metal stud partition systems, each with a different application.

How To - Install ShaftWall

C106053 (EN)
Gypframe 60 I 70 'I' Stud @ 600mm centres & Gypframe MF5 Ceiling Sections @ 450mm centres
2 x 15mm Gyproc FireLine (+ 19mm Gyproc CoreBoard in cavity)
N/A
N/A
120
2500
N/A
60
60
42

close
ShaftWall

ShaftWall

Shaft and duct encasement system.

ShaftWall provides a lightweight, fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an early stage of the construction without the need for scaffolding. The system can also be built horizontally to provide a fire rated membrane.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close ShaftWall

ShaftWall

Shaft and duct encasement system.

ShaftWall provides a lightweight, fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an early stage of the construction without the need for scaffolding. The system can also be built horizontally to provide a fire rated membrane.

  • Horizontal membranes are built entirely from below
  • A ShaftWall variant with non-combustible Glasroc F FireCase board linings is available
  • High level commonality with GypWall partition components, particularly 70mm stud solutions
  • Higher certainty of installed acoustic performance due to laboratory tests incorporating deflection heads
  • Can be used where access is limited to one side at the head, e.g. M & E cages already installed in corridors

Is Gyproc FireStrip required

Where included in the detail, Gyproc FireStrip is an essential component in maintaining the fire resistance of a partition.

How do you build a fire-rated partition where access is limited to one side only?

Our ShaftWall system is designed for this application.

What are Staggered, Quiet, Quiet SF, Audio, ShaftWall stud partitions?

These are all types of British Gypsum metal stud partition systems, each with a different application.

How To - Install ShaftWall

C106054
Gypframe 92 I 90 'I' Stud @ 600mm centres & Gypframe MF5 Ceiling Sections @ 450mm centres
2 x 15mm Gyproc FireLine (+ 19mm Gyproc CoreBoard in cavity)
N/A
N/A
152
3700
N/A
60
60
44

close
ShaftWall

ShaftWall

Shaft and duct encasement system.

ShaftWall provides a lightweight, fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an early stage of the construction without the need for scaffolding. The system can also be built horizontally to provide a fire rated membrane.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close ShaftWall

ShaftWall

Shaft and duct encasement system.

ShaftWall provides a lightweight, fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an early stage of the construction without the need for scaffolding. The system can also be built horizontally to provide a fire rated membrane.

  • Horizontal membranes are built entirely from below
  • A ShaftWall variant with non-combustible Glasroc F FireCase board linings is available
  • High level commonality with GypWall partition components, particularly 70mm stud solutions
  • Higher certainty of installed acoustic performance due to laboratory tests incorporating deflection heads
  • Can be used where access is limited to one side at the head, e.g. M & E cages already installed in corridors

Is Gyproc FireStrip required

Where included in the detail, Gyproc FireStrip is an essential component in maintaining the fire resistance of a partition.

How do you build a fire-rated partition where access is limited to one side only?

Our ShaftWall system is designed for this application.

What are Staggered, Quiet, Quiet SF, Audio, ShaftWall stud partitions?

These are all types of British Gypsum metal stud partition systems, each with a different application.

How To - Install ShaftWall

C106054 (EN)
Gypframe 92 I 90 'I' Stud @ 600mm centres & Gypframe MF5 Ceiling Sections @ 450mm centres
2 x 15mm Gyproc FireLine (+ 19mm Gyproc CoreBoard in cavity)
N/A
N/A
152
3000
N/A
60
60
44

close
ShaftWall

ShaftWall

Shaft and duct encasement system.

ShaftWall provides a lightweight, fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an early stage of the construction without the need for scaffolding. The system can also be built horizontally to provide a fire rated membrane.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close ShaftWall

ShaftWall

Shaft and duct encasement system.

ShaftWall provides a lightweight, fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an early stage of the construction without the need for scaffolding. The system can also be built horizontally to provide a fire rated membrane.

  • Horizontal membranes are built entirely from below
  • A ShaftWall variant with non-combustible Glasroc F FireCase board linings is available
  • High level commonality with GypWall partition components, particularly 70mm stud solutions
  • Higher certainty of installed acoustic performance due to laboratory tests incorporating deflection heads
  • Can be used where access is limited to one side at the head, e.g. M & E cages already installed in corridors

Is Gyproc FireStrip required

Where included in the detail, Gyproc FireStrip is an essential component in maintaining the fire resistance of a partition.

How do you build a fire-rated partition where access is limited to one side only?

Our ShaftWall system is designed for this application.

What are Staggered, Quiet, Quiet SF, Audio, ShaftWall stud partitions?

These are all types of British Gypsum metal stud partition systems, each with a different application.

How To - Install ShaftWall

C106055
Gypframe 146 TI 90 Tabbed 'I' Stud @ 600mm centres & Gypframe MF5 Ceiling Sections @ 450mm centres
2 x 15mm Gyproc FireLine (+ 19mm Gyproc CoreBoard in cavity)
N/A
N/A
206
5100
N/A
60
60
48

close
ShaftWall

ShaftWall

Shaft and duct encasement system.

ShaftWall provides a lightweight, fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an early stage of the construction without the need for scaffolding. The system can also be built horizontally to provide a fire rated membrane.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close ShaftWall

ShaftWall

Shaft and duct encasement system.

ShaftWall provides a lightweight, fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an early stage of the construction without the need for scaffolding. The system can also be built horizontally to provide a fire rated membrane.

  • Horizontal membranes are built entirely from below
  • A ShaftWall variant with non-combustible Glasroc F FireCase board linings is available
  • High level commonality with GypWall partition components, particularly 70mm stud solutions
  • Higher certainty of installed acoustic performance due to laboratory tests incorporating deflection heads
  • Can be used where access is limited to one side at the head, e.g. M & E cages already installed in corridors

Is Gyproc FireStrip required

Where included in the detail, Gyproc FireStrip is an essential component in maintaining the fire resistance of a partition.

How do you build a fire-rated partition where access is limited to one side only?

Our ShaftWall system is designed for this application.

What are Staggered, Quiet, Quiet SF, Audio, ShaftWall stud partitions?

These are all types of British Gypsum metal stud partition systems, each with a different application.

How To - Install ShaftWall

C106055 (EN)
Gypframe 146 TI 90 Tabbed 'I' Stud @ 600mm centres & Gypframe MF5 Ceiling Sections @ 450mm centres
2 x 15mm Gyproc FireLine (+ 19mm Gyproc CoreBoard in cavity)
N/A
N/A
206
4000
N/A
60
60
48

close
ShaftWall

ShaftWall

Shaft and duct encasement system.

ShaftWall provides a lightweight, fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an early stage of the construction without the need for scaffolding. The system can also be built horizontally to provide a fire rated membrane.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close ShaftWall

ShaftWall

Shaft and duct encasement system.

ShaftWall provides a lightweight, fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an early stage of the construction without the need for scaffolding. The system can also be built horizontally to provide a fire rated membrane.

  • Horizontal membranes are built entirely from below
  • A ShaftWall variant with non-combustible Glasroc F FireCase board linings is available
  • High level commonality with GypWall partition components, particularly 70mm stud solutions
  • Higher certainty of installed acoustic performance due to laboratory tests incorporating deflection heads
  • Can be used where access is limited to one side at the head, e.g. M & E cages already installed in corridors

Is Gyproc FireStrip required

Where included in the detail, Gyproc FireStrip is an essential component in maintaining the fire resistance of a partition.

How do you build a fire-rated partition where access is limited to one side only?

Our ShaftWall system is designed for this application.

What are Staggered, Quiet, Quiet SF, Audio, ShaftWall stud partitions?

These are all types of British Gypsum metal stud partition systems, each with a different application.

How To - Install ShaftWall

C106056
Gypframe 146 TI 90 Tabbed 'I' Stud @ 600mm centres & Gypframe MF5 Ceiling Sections @ 450mm centres
2 x 15mm Gyproc FireLine (+ 19mm Gyproc CoreBoard in cavity)
Gypframe 146 TI 90 Tabbed 'I' Stud @ 600mm centres
2 x 15mm Gyproc FireLine (+ 19mm Gyproc CoreBoard in cavity)
422
5100
N/A
120
120
48

close
ShaftWall

ShaftWall

Shaft and duct encasement system.

ShaftWall provides a lightweight, fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an early stage of the construction without the need for scaffolding. The system can also be built horizontally to provide a fire rated membrane.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close ShaftWall

ShaftWall

Shaft and duct encasement system.

ShaftWall provides a lightweight, fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an early stage of the construction without the need for scaffolding. The system can also be built horizontally to provide a fire rated membrane.

  • Horizontal membranes are built entirely from below
  • A ShaftWall variant with non-combustible Glasroc F FireCase board linings is available
  • High level commonality with GypWall partition components, particularly 70mm stud solutions
  • Higher certainty of installed acoustic performance due to laboratory tests incorporating deflection heads
  • Can be used where access is limited to one side at the head, e.g. M & E cages already installed in corridors

Is Gyproc FireStrip required

Where included in the detail, Gyproc FireStrip is an essential component in maintaining the fire resistance of a partition.

How do you build a fire-rated partition where access is limited to one side only?

Our ShaftWall system is designed for this application.

What are Staggered, Quiet, Quiet SF, Audio, ShaftWall stud partitions?

These are all types of British Gypsum metal stud partition systems, each with a different application.

How To - Install ShaftWall

C106056 (EN)
Gypframe 146 TI 90 Tabbed 'I' Stud @ 600mm centres & Gypframe MF5 Ceiling Sections @ 450mm centres
2 x 15mm Gyproc FireLine (+ 19mm Gyproc CoreBoard in cavity)
Gypframe 146 TI 90 Tabbed 'I' Stud @ 600mm centres
2 x 15mm Gyproc FireLine (+ 19mm Gyproc CoreBoard in cavity)
422
4000
N/A
120
120
48

close
ShaftWall

ShaftWall

Shaft and duct encasement system.

ShaftWall provides a lightweight, fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an early stage of the construction without the need for scaffolding. The system can also be built horizontally to provide a fire rated membrane.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close ShaftWall

ShaftWall

Shaft and duct encasement system.

ShaftWall provides a lightweight, fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an early stage of the construction without the need for scaffolding. The system can also be built horizontally to provide a fire rated membrane.

  • Horizontal membranes are built entirely from below
  • A ShaftWall variant with non-combustible Glasroc F FireCase board linings is available
  • High level commonality with GypWall partition components, particularly 70mm stud solutions
  • Higher certainty of installed acoustic performance due to laboratory tests incorporating deflection heads
  • Can be used where access is limited to one side at the head, e.g. M & E cages already installed in corridors

Is Gyproc FireStrip required

Where included in the detail, Gyproc FireStrip is an essential component in maintaining the fire resistance of a partition.

How do you build a fire-rated partition where access is limited to one side only?

Our ShaftWall system is designed for this application.

What are Staggered, Quiet, Quiet SF, Audio, ShaftWall stud partitions?

These are all types of British Gypsum metal stud partition systems, each with a different application.

How To - Install ShaftWall

C106057
Gypframe 146 TI 90 Tabbed 'I' Stud @ 600mm centres & Gypframe MF5 Ceiling Sections @ 450mm centres
2 x 15mm Gyproc FireLine (+ 19mm Gyproc CoreBoard in cavity)
Gypframe 146 TI 90 Tabbed 'I' Stud @ 600mm centres
1 x 15mm Gyproc FireLine (+ 19mm Gyproc CoreBoard in cavity)
397
5100
N/A
90
90
48

close
ShaftWall

ShaftWall

Shaft and duct encasement system.

ShaftWall provides a lightweight, fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an early stage of the construction without the need for scaffolding. The system can also be built horizontally to provide a fire rated membrane.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close ShaftWall

ShaftWall

Shaft and duct encasement system.

ShaftWall provides a lightweight, fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an early stage of the construction without the need for scaffolding. The system can also be built horizontally to provide a fire rated membrane.

  • Horizontal membranes are built entirely from below
  • A ShaftWall variant with non-combustible Glasroc F FireCase board linings is available
  • High level commonality with GypWall partition components, particularly 70mm stud solutions
  • Higher certainty of installed acoustic performance due to laboratory tests incorporating deflection heads
  • Can be used where access is limited to one side at the head, e.g. M & E cages already installed in corridors

Is Gyproc FireStrip required

Where included in the detail, Gyproc FireStrip is an essential component in maintaining the fire resistance of a partition.

How do you build a fire-rated partition where access is limited to one side only?

Our ShaftWall system is designed for this application.

What are Staggered, Quiet, Quiet SF, Audio, ShaftWall stud partitions?

These are all types of British Gypsum metal stud partition systems, each with a different application.

How To - Install ShaftWall

C106057 (EN)
Gypframe 146 TI 90 Tabbed 'I' Stud @ 600mm centres & Gypframe MF5 Ceiling Sections @ 450mm centres
2 x 15mm Gyproc FireLine (+ 19mm Gyproc CoreBoard in cavity)
Gypframe 146 TI 90 Tabbed 'I' Stud @ 600mm centres
1 x 15mm Gyproc FireLine (+ 19mm Gyproc CoreBoard in cavity)
397
4400
N/A
90
90
48

close
ShaftWall

ShaftWall

Shaft and duct encasement system.

ShaftWall provides a lightweight, fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an early stage of the construction without the need for scaffolding. The system can also be built horizontally to provide a fire rated membrane.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close ShaftWall

ShaftWall

Shaft and duct encasement system.

ShaftWall provides a lightweight, fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an early stage of the construction without the need for scaffolding. The system can also be built horizontally to provide a fire rated membrane.

  • Horizontal membranes are built entirely from below
  • A ShaftWall variant with non-combustible Glasroc F FireCase board linings is available
  • High level commonality with GypWall partition components, particularly 70mm stud solutions
  • Higher certainty of installed acoustic performance due to laboratory tests incorporating deflection heads
  • Can be used where access is limited to one side at the head, e.g. M & E cages already installed in corridors

Is Gyproc FireStrip required

Where included in the detail, Gyproc FireStrip is an essential component in maintaining the fire resistance of a partition.

How do you build a fire-rated partition where access is limited to one side only?

Our ShaftWall system is designed for this application.

What are Staggered, Quiet, Quiet SF, Audio, ShaftWall stud partitions?

These are all types of British Gypsum metal stud partition systems, each with a different application.

How To - Install ShaftWall

Export results as .csv
System System Ref Background Stud type / Adhesive Centres (mm) Board side 1 Insulation Cavity / Offset (mm) Fire Integrity (mins) Fire Insulation (mins) Max. Partition Height (mm) Sound Insulation
Rw dB
Rw + Ctr dB Fire Protection (mins) Section Factor A/V (HP/A) m-1 (max) Go to basket
B216001 (A)
Masonry (180kg/m2)
Gypframe 48 I 50 'I' Stud
600
Gyproc WallBoard (12.5)
50mm Isover Steel Frame Infill Batt
10
N/A
N/A
2400
59
51
N/A
N/A

close
GypLyner IWL

GypLyner IWL

Independent wall lining system

GypLyner IWL independent wall lining is a lightweight, non-loadbearing system, which is built independently of the external wall construction. GypLyner IWL is particularly suitable for buildings where fixing into the background is difficult or not possible. The lining provides fire resistance and acoustic upgrades to structural steel sections clad with lightweight metal sheeting, and can also be used in within new or existing masonry walls to increase sound insulation and meet stringent thermal performance requirements.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close GypLyner IWL

GypLyner IWL

Independent wall lining system

GypLyner IWL independent wall lining is a lightweight, non-loadbearing system, which is built independently of the external wall construction. GypLyner IWL is particularly suitable for buildings where fixing into the background is difficult or not possible. The lining provides fire resistance and acoustic upgrades to structural steel sections clad with lightweight metal sheeting, and can also be used in within new or existing masonry walls to increase sound insulation and meet stringent thermal performance requirements.

  • Totally independent from wall with fixings to floor and soffit only, particularly suitable for basements with waterproof tanking
  • Any surface irregularities within the external wall construction are completely removed through the totally independent framework
  • Services are easily incorporated within the framework with no limitation to the cavity size that can be created
  • A wide range of U-values can be achieved to suit project requirements through our extensive selection of Gyproc ThermaLine laminate types and thicknesses
  • Minimal thermal bridging due to the use of a totally independent framework
  • Provides a high-performance option to achieve enhanced acoustic performance and fire protection to steel, in one lining solution

How do I acoustically upgrade an existing masonry wall?

Use Gyproc SoundBloc board and Isover insulation within GypLyner IWL or GypLyner UNIVERSAL systems. Selection depends on a number of factors such as type of background, height of lining and performance requirements and board type. Please refer to the relevant sections of the White Book for further information if required.

How do you deal with salt contamination in the background?

Salt contamination will usually be due to prolonged condensation or damp issues that need to be resolved before going any further.

What wall lining systems are available and how would you select the correct type?

We offer a number of wall lining systems including DriLyner, GypLyner UNIVERSAL and GypLyner IWL for a range of applications.

How To - Install GypLyner IWL

B216001 (B)
Masonry (180kg/m2)
Gypframe 60 I 50 'I' Stud
600
Gyproc WallBoard (12.5)
50mm Isover Steel Frame Infill Batt
10
N/A
N/A
2400
59
51
N/A
N/A

close
GypLyner IWL

GypLyner IWL

Independent wall lining system

GypLyner IWL independent wall lining is a lightweight, non-loadbearing system, which is built independently of the external wall construction. GypLyner IWL is particularly suitable for buildings where fixing into the background is difficult or not possible. The lining provides fire resistance and acoustic upgrades to structural steel sections clad with lightweight metal sheeting, and can also be used in within new or existing masonry walls to increase sound insulation and meet stringent thermal performance requirements.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close GypLyner IWL

GypLyner IWL

Independent wall lining system

GypLyner IWL independent wall lining is a lightweight, non-loadbearing system, which is built independently of the external wall construction. GypLyner IWL is particularly suitable for buildings where fixing into the background is difficult or not possible. The lining provides fire resistance and acoustic upgrades to structural steel sections clad with lightweight metal sheeting, and can also be used in within new or existing masonry walls to increase sound insulation and meet stringent thermal performance requirements.

  • Totally independent from wall with fixings to floor and soffit only, particularly suitable for basements with waterproof tanking
  • Any surface irregularities within the external wall construction are completely removed through the totally independent framework
  • Services are easily incorporated within the framework with no limitation to the cavity size that can be created
  • A wide range of U-values can be achieved to suit project requirements through our extensive selection of Gyproc ThermaLine laminate types and thicknesses
  • Minimal thermal bridging due to the use of a totally independent framework
  • Provides a high-performance option to achieve enhanced acoustic performance and fire protection to steel, in one lining solution

How do I acoustically upgrade an existing masonry wall?

Use Gyproc SoundBloc board and Isover insulation within GypLyner IWL or GypLyner UNIVERSAL systems. Selection depends on a number of factors such as type of background, height of lining and performance requirements and board type. Please refer to the relevant sections of the White Book for further information if required.

How do you deal with salt contamination in the background?

Salt contamination will usually be due to prolonged condensation or damp issues that need to be resolved before going any further.

What wall lining systems are available and how would you select the correct type?

We offer a number of wall lining systems including DriLyner, GypLyner UNIVERSAL and GypLyner IWL for a range of applications.

How To - Install GypLyner IWL

B216001 (C)
Masonry (180kg/m2)
Gypframe 60 I 70 'I' Stud
600
Gyproc WallBoard (12.5)
50mm Isover Steel Frame Infill Batt
10
N/A
N/A
3000
59
51
N/A
N/A

close
GypLyner IWL

GypLyner IWL

Independent wall lining system

GypLyner IWL independent wall lining is a lightweight, non-loadbearing system, which is built independently of the external wall construction. GypLyner IWL is particularly suitable for buildings where fixing into the background is difficult or not possible. The lining provides fire resistance and acoustic upgrades to structural steel sections clad with lightweight metal sheeting, and can also be used in within new or existing masonry walls to increase sound insulation and meet stringent thermal performance requirements.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close GypLyner IWL

GypLyner IWL

Independent wall lining system

GypLyner IWL independent wall lining is a lightweight, non-loadbearing system, which is built independently of the external wall construction. GypLyner IWL is particularly suitable for buildings where fixing into the background is difficult or not possible. The lining provides fire resistance and acoustic upgrades to structural steel sections clad with lightweight metal sheeting, and can also be used in within new or existing masonry walls to increase sound insulation and meet stringent thermal performance requirements.

  • Totally independent from wall with fixings to floor and soffit only, particularly suitable for basements with waterproof tanking
  • Any surface irregularities within the external wall construction are completely removed through the totally independent framework
  • Services are easily incorporated within the framework with no limitation to the cavity size that can be created
  • A wide range of U-values can be achieved to suit project requirements through our extensive selection of Gyproc ThermaLine laminate types and thicknesses
  • Minimal thermal bridging due to the use of a totally independent framework
  • Provides a high-performance option to achieve enhanced acoustic performance and fire protection to steel, in one lining solution

How do I acoustically upgrade an existing masonry wall?

Use Gyproc SoundBloc board and Isover insulation within GypLyner IWL or GypLyner UNIVERSAL systems. Selection depends on a number of factors such as type of background, height of lining and performance requirements and board type. Please refer to the relevant sections of the White Book for further information if required.

How do you deal with salt contamination in the background?

Salt contamination will usually be due to prolonged condensation or damp issues that need to be resolved before going any further.

What wall lining systems are available and how would you select the correct type?

We offer a number of wall lining systems including DriLyner, GypLyner UNIVERSAL and GypLyner IWL for a range of applications.

How To - Install GypLyner IWL

B216001 (D)
Masonry (180kg/m2)
Gypframe 70 I 70 'I' Stud
600
Gyproc WallBoard (12.5)
50mm Isover Steel Frame Infill Batt
10
N/A
N/A
3600
59
51
N/A
N/A

close
GypLyner IWL

GypLyner IWL

Independent wall lining system

GypLyner IWL independent wall lining is a lightweight, non-loadbearing system, which is built independently of the external wall construction. GypLyner IWL is particularly suitable for buildings where fixing into the background is difficult or not possible. The lining provides fire resistance and acoustic upgrades to structural steel sections clad with lightweight metal sheeting, and can also be used in within new or existing masonry walls to increase sound insulation and meet stringent thermal performance requirements.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close GypLyner IWL

GypLyner IWL

Independent wall lining system

GypLyner IWL independent wall lining is a lightweight, non-loadbearing system, which is built independently of the external wall construction. GypLyner IWL is particularly suitable for buildings where fixing into the background is difficult or not possible. The lining provides fire resistance and acoustic upgrades to structural steel sections clad with lightweight metal sheeting, and can also be used in within new or existing masonry walls to increase sound insulation and meet stringent thermal performance requirements.

  • Totally independent from wall with fixings to floor and soffit only, particularly suitable for basements with waterproof tanking
  • Any surface irregularities within the external wall construction are completely removed through the totally independent framework
  • Services are easily incorporated within the framework with no limitation to the cavity size that can be created
  • A wide range of U-values can be achieved to suit project requirements through our extensive selection of Gyproc ThermaLine laminate types and thicknesses
  • Minimal thermal bridging due to the use of a totally independent framework
  • Provides a high-performance option to achieve enhanced acoustic performance and fire protection to steel, in one lining solution

How do I acoustically upgrade an existing masonry wall?

Use Gyproc SoundBloc board and Isover insulation within GypLyner IWL or GypLyner UNIVERSAL systems. Selection depends on a number of factors such as type of background, height of lining and performance requirements and board type. Please refer to the relevant sections of the White Book for further information if required.

How do you deal with salt contamination in the background?

Salt contamination will usually be due to prolonged condensation or damp issues that need to be resolved before going any further.

What wall lining systems are available and how would you select the correct type?

We offer a number of wall lining systems including DriLyner, GypLyner UNIVERSAL and GypLyner IWL for a range of applications.

How To - Install GypLyner IWL

B216001 (E)
Masonry (180kg/m2)
Gypframe 92 I 90 'I' Stud
600
Gyproc WallBoard (12.5)
50mm Isover Steel Frame Infill Batt
10
N/A
N/A
5100
59
51
N/A
N/A

close
GypLyner IWL

GypLyner IWL

Independent wall lining system

GypLyner IWL independent wall lining is a lightweight, non-loadbearing system, which is built independently of the external wall construction. GypLyner IWL is particularly suitable for buildings where fixing into the background is difficult or not possible. The lining provides fire resistance and acoustic upgrades to structural steel sections clad with lightweight metal sheeting, and can also be used in within new or existing masonry walls to increase sound insulation and meet stringent thermal performance requirements.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close GypLyner IWL

GypLyner IWL

Independent wall lining system

GypLyner IWL independent wall lining is a lightweight, non-loadbearing system, which is built independently of the external wall construction. GypLyner IWL is particularly suitable for buildings where fixing into the background is difficult or not possible. The lining provides fire resistance and acoustic upgrades to structural steel sections clad with lightweight metal sheeting, and can also be used in within new or existing masonry walls to increase sound insulation and meet stringent thermal performance requirements.

  • Totally independent from wall with fixings to floor and soffit only, particularly suitable for basements with waterproof tanking
  • Any surface irregularities within the external wall construction are completely removed through the totally independent framework
  • Services are easily incorporated within the framework with no limitation to the cavity size that can be created
  • A wide range of U-values can be achieved to suit project requirements through our extensive selection of Gyproc ThermaLine laminate types and thicknesses
  • Minimal thermal bridging due to the use of a totally independent framework
  • Provides a high-performance option to achieve enhanced acoustic performance and fire protection to steel, in one lining solution

How do I acoustically upgrade an existing masonry wall?

Use Gyproc SoundBloc board and Isover insulation within GypLyner IWL or GypLyner UNIVERSAL systems. Selection depends on a number of factors such as type of background, height of lining and performance requirements and board type. Please refer to the relevant sections of the White Book for further information if required.

How do you deal with salt contamination in the background?

Salt contamination will usually be due to prolonged condensation or damp issues that need to be resolved before going any further.

What wall lining systems are available and how would you select the correct type?

We offer a number of wall lining systems including DriLyner, GypLyner UNIVERSAL and GypLyner IWL for a range of applications.

How To - Install GypLyner IWL

B216001 (F)
Masonry (180kg/m2)
Gypframe 146 I 80 'I' Stud
600
Gyproc WallBoard (12.5)
50mm Isover Steel Frame Infill Batt
10
N/A
N/A
6900
59
51
N/A
N/A

close
GypLyner IWL

GypLyner IWL

Independent wall lining system

GypLyner IWL independent wall lining is a lightweight, non-loadbearing system, which is built independently of the external wall construction. GypLyner IWL is particularly suitable for buildings where fixing into the background is difficult or not possible. The lining provides fire resistance and acoustic upgrades to structural steel sections clad with lightweight metal sheeting, and can also be used in within new or existing masonry walls to increase sound insulation and meet stringent thermal performance requirements.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close GypLyner IWL

GypLyner IWL

Independent wall lining system

GypLyner IWL independent wall lining is a lightweight, non-loadbearing system, which is built independently of the external wall construction. GypLyner IWL is particularly suitable for buildings where fixing into the background is difficult or not possible. The lining provides fire resistance and acoustic upgrades to structural steel sections clad with lightweight metal sheeting, and can also be used in within new or existing masonry walls to increase sound insulation and meet stringent thermal performance requirements.

  • Totally independent from wall with fixings to floor and soffit only, particularly suitable for basements with waterproof tanking
  • Any surface irregularities within the external wall construction are completely removed through the totally independent framework
  • Services are easily incorporated within the framework with no limitation to the cavity size that can be created
  • A wide range of U-values can be achieved to suit project requirements through our extensive selection of Gyproc ThermaLine laminate types and thicknesses
  • Minimal thermal bridging due to the use of a totally independent framework
  • Provides a high-performance option to achieve enhanced acoustic performance and fire protection to steel, in one lining solution

How do I acoustically upgrade an existing masonry wall?

Use Gyproc SoundBloc board and Isover insulation within GypLyner IWL or GypLyner UNIVERSAL systems. Selection depends on a number of factors such as type of background, height of lining and performance requirements and board type. Please refer to the relevant sections of the White Book for further information if required.

How do you deal with salt contamination in the background?

Salt contamination will usually be due to prolonged condensation or damp issues that need to be resolved before going any further.

What wall lining systems are available and how would you select the correct type?

We offer a number of wall lining systems including DriLyner, GypLyner UNIVERSAL and GypLyner IWL for a range of applications.

How To - Install GypLyner IWL

B216002 (A)
Masonry (180kg/m2)
Gypframe 48 I 50 'I' Stud
600
Gyproc WallBoard (15)
50mm Isover Steel Frame Infill Batt
10
N/A
N/A
2400
59
51
N/A
N/A

close
GypLyner IWL

GypLyner IWL

Independent wall lining system

GypLyner IWL independent wall lining is a lightweight, non-loadbearing system, which is built independently of the external wall construction. GypLyner IWL is particularly suitable for buildings where fixing into the background is difficult or not possible. The lining provides fire resistance and acoustic upgrades to structural steel sections clad with lightweight metal sheeting, and can also be used in within new or existing masonry walls to increase sound insulation and meet stringent thermal performance requirements.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close GypLyner IWL

GypLyner IWL

Independent wall lining system

GypLyner IWL independent wall lining is a lightweight, non-loadbearing system, which is built independently of the external wall construction. GypLyner IWL is particularly suitable for buildings where fixing into the background is difficult or not possible. The lining provides fire resistance and acoustic upgrades to structural steel sections clad with lightweight metal sheeting, and can also be used in within new or existing masonry walls to increase sound insulation and meet stringent thermal performance requirements.

  • Totally independent from wall with fixings to floor and soffit only, particularly suitable for basements with waterproof tanking
  • Any surface irregularities within the external wall construction are completely removed through the totally independent framework
  • Services are easily incorporated within the framework with no limitation to the cavity size that can be created
  • A wide range of U-values can be achieved to suit project requirements through our extensive selection of Gyproc ThermaLine laminate types and thicknesses
  • Minimal thermal bridging due to the use of a totally independent framework
  • Provides a high-performance option to achieve enhanced acoustic performance and fire protection to steel, in one lining solution

How do I acoustically upgrade an existing masonry wall?

Use Gyproc SoundBloc board and Isover insulation within GypLyner IWL or GypLyner UNIVERSAL systems. Selection depends on a number of factors such as type of background, height of lining and performance requirements and board type. Please refer to the relevant sections of the White Book for further information if required.

How do you deal with salt contamination in the background?

Salt contamination will usually be due to prolonged condensation or damp issues that need to be resolved before going any further.

What wall lining systems are available and how would you select the correct type?

We offer a number of wall lining systems including DriLyner, GypLyner UNIVERSAL and GypLyner IWL for a range of applications.

How To - Install GypLyner IWL

B216002 (B)
Masonry (180kg/m2)
Gypframe 60 I 50 'I' Stud
600
Gyproc WallBoard (15)
50mm Isover Steel Frame Infill Batt
10
N/A
N/A
2700
59
51
N/A
N/A

close
GypLyner IWL

GypLyner IWL

Independent wall lining system

GypLyner IWL independent wall lining is a lightweight, non-loadbearing system, which is built independently of the external wall construction. GypLyner IWL is particularly suitable for buildings where fixing into the background is difficult or not possible. The lining provides fire resistance and acoustic upgrades to structural steel sections clad with lightweight metal sheeting, and can also be used in within new or existing masonry walls to increase sound insulation and meet stringent thermal performance requirements.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close GypLyner IWL

GypLyner IWL

Independent wall lining system

GypLyner IWL independent wall lining is a lightweight, non-loadbearing system, which is built independently of the external wall construction. GypLyner IWL is particularly suitable for buildings where fixing into the background is difficult or not possible. The lining provides fire resistance and acoustic upgrades to structural steel sections clad with lightweight metal sheeting, and can also be used in within new or existing masonry walls to increase sound insulation and meet stringent thermal performance requirements.

  • Totally independent from wall with fixings to floor and soffit only, particularly suitable for basements with waterproof tanking
  • Any surface irregularities within the external wall construction are completely removed through the totally independent framework
  • Services are easily incorporated within the framework with no limitation to the cavity size that can be created
  • A wide range of U-values can be achieved to suit project requirements through our extensive selection of Gyproc ThermaLine laminate types and thicknesses
  • Minimal thermal bridging due to the use of a totally independent framework
  • Provides a high-performance option to achieve enhanced acoustic performance and fire protection to steel, in one lining solution

How do I acoustically upgrade an existing masonry wall?

Use Gyproc SoundBloc board and Isover insulation within GypLyner IWL or GypLyner UNIVERSAL systems. Selection depends on a number of factors such as type of background, height of lining and performance requirements and board type. Please refer to the relevant sections of the White Book for further information if required.

How do you deal with salt contamination in the background?

Salt contamination will usually be due to prolonged condensation or damp issues that need to be resolved before going any further.

What wall lining systems are available and how would you select the correct type?

We offer a number of wall lining systems including DriLyner, GypLyner UNIVERSAL and GypLyner IWL for a range of applications.

How To - Install GypLyner IWL

B216002 (C)
Masonry (180kg/m2)
Gypframe 60 I 70 'I' Stud
600
Gyproc WallBoard (15)
50mm Isover Steel Frame Infill Batt
10
N/A
N/A
3300
59
51
N/A
N/A

close
GypLyner IWL

GypLyner IWL

Independent wall lining system

GypLyner IWL independent wall lining is a lightweight, non-loadbearing system, which is built independently of the external wall construction. GypLyner IWL is particularly suitable for buildings where fixing into the background is difficult or not possible. The lining provides fire resistance and acoustic upgrades to structural steel sections clad with lightweight metal sheeting, and can also be used in within new or existing masonry walls to increase sound insulation and meet stringent thermal performance requirements.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files

Close GypLyner IWL

GypLyner IWL

Independent wall lining system

GypLyner IWL independent wall lining is a lightweight, non-loadbearing system, which is built independently of the external wall construction. GypLyner IWL is particularly suitable for buildings where fixing into the background is difficult or not possible. The lining provides fire resistance and acoustic upgrades to structural steel sections clad with lightweight metal sheeting, and can also be used in within new or existing masonry walls to increase sound insulation and meet stringent thermal performance requirements.

  • Totally independent from wall with fixings to floor and soffit only, particularly suitable for basements with waterproof tanking
  • Any surface irregularities within the external wall construction are completely removed through the totally independent framework
  • Services are easily incorporated within the framework with no limitation to the cavity size that can be created
  • A wide range of U-values can be achieved to suit project requirements through our extensive selection of Gyproc ThermaLine laminate types and thicknesses
  • Minimal thermal bridging due to the use of a totally independent framework
  • Provides a high-performance option to achieve enhanced acoustic performance and fire protection to steel, in one lining solution

How do I acoustically upgrade an existing masonry wall?

Use Gyproc SoundBloc board and Isover insulation within GypLyner IWL or GypLyner UNIVERSAL systems. Selection depends on a number of factors such as type of background, height of lining and performance requirements and board type. Please refer to the relevant sections of the White Book for further information if required.

How do you deal with salt contamination in the background?

Salt contamination will usually be due to prolonged condensation or damp issues that need to be resolved before going any further.

What wall lining systems are available and how would you select the correct type?

We offer a number of wall lining systems including DriLyner, GypLyner UNIVERSAL and GypLyner IWL for a range of applications.

How To - Install GypLyner IWL

B216002 (D)
Masonry (180kg/m2)
Gypframe 70 I 70 'I' Stud
600
Gyproc WallBoard (15)
50mm Isover Steel Frame Infill Batt
10
N/A
N/A
3900
59
51
N/A
N/A

close
GypLyner IWL

GypLyner IWL

Independent wall lining system

GypLyner IWL independent wall lining is a lightweight, non-loadbearing system, which is built independently of the external wall construction. GypLyner IWL is particularly suitable for buildings where fixing into the background is difficult or not possible. The lining provides fire resistance and acoustic upgrades to structural steel sections clad with lightweight metal sheeting, and can also be used in within new or existing masonry walls to increase sound insulation and meet stringent thermal performance requirements.


You will need to register and login to access premium files such as NBS (word & PDF), .dwg CAD, and .rvt BIM files