"Solution Product Name","Solution Product Description","Last review date","Last updated date","Minimum Cavity / Offset (mm)","Finishing Requirements","Fixing Method","Other Requirements","Secondary fixing","Thermal sealant","Fixing method",Sealant,"Parge coat","Board side 1, Layer 1" "TL-PLUS (C) (EN)","One layer of Gyproc ThermaLine Plus 40mm on Gyproc DriWall Adhesive dabs (10mm nominal cavity) on solid masonry background",27.09.2021,21.07.2023,10,"The system should be finished using either one of our Thistle or ThistlePro plasters, or Gyproc jointing products. See the product range guides on the British Gypsum website for more information.","Apply dabs of adhesive to the background for one board at a time, to achieve at least 20% contact with the surface area of the boards. One row of horizontal dabs to coincide with the top edge of each board. One continuous line of horizontal dabs to coincide with the bottom edge of each board. One row of vertical dabs to coincide with the side edges of each board, and additional vertical row(s) at 600mm maximum centres. Ensure dabs are at least 25mm from board edges.","SpecSure® system performance warranty confirms that British Gypsum proprietary systems will perform as specified for the lifetime of the building. The SpecSure® warranty requires that all components are specified in full and constructed in accordance with British Gypsum’s installation guidance. For more details see the British Gypsum website. Always check with the design team before making any changes to the chosen specification, ensuring appropriate substantiation is sought to confirm that the solution still meets all required project performances.","British Gypsum Nailable Plugs 80mm","Gyproc DriWall Adhesive","Gyproc DriWall Adhesive","Gyproc Sealant","Gyproc SoundCoat Plus","Gyproc ThermaLine Plus 40mm"