Wall Linings
Our versatile specifications cater for a range of wall and roof constructions, including-metal frame and traditional masonry.
We cover all wall lining applications, from high-performance solutions that meet thermal, acoustic, fire-protection or impact-resistance requirements.
Linings can be fully or partially independent of the structure, or can simply be bonded or plastered directly to a wall surface. These systems can be used in all types of buildings and are equally suited to both new-build and refurbishment work.
Please note that all British Gypsum Drylining systems are tested to the BS EN fire test standard. However we can continue to support your BS Standard Specifications project with remaining test evidence to BS 476. Please click here for more information.
Watch this short video to see how to use this EN Specification Selector and where you can still get details of our BS Specifications.
- Gypframe 50 FEC 50 Folded Edge Standard Floor & Ceiling Channel (1)
- Gypframe 62 FEC 50 Folded Edge Standard Floor & Ceiling Channel (2)
- Gypframe 72 FEC 50 Folded Edge Standard Floor & Ceiling Channel (1)
- Gypframe 94 DC 60 Deep Flange Floor & Ceiling Channel (1)
- Gypframe 94 FEC 50 Folded Edge Standard Floor & Ceiling Channel (1)
- Gypframe 148 DC 60 Deep Flange Floor & Ceiling Channel (1)
- Gypframe 148 FEC 50 Folded Edge Standard Floor & Ceiling Channel (1)
- Gypframe GL1 Lining Channel (1)
- Gypframe GL2 Bracket (1)
- Gypframe GL3 Channel Connector (1)
- Gypframe GL8 Track (1)
- Gypframe GL11 GypLyner Anchor (1)
GIWL 146 I 80 PIR (A) (EN)
One layer of Gyproc ThermaLine PIR 38mm to one side of Gypframe 146 I 80 ‘I’ Stud framework forming an independent lining to masonry background. For heights up to 4200mm.
GIWL 146 I 80 PIR (B) (EN)
One layer of Gyproc ThermaLine PIR 38mm to one side of Gypframe 146 I 80 ‘I’ Stud framework forming an independent lining to masonry background. For heights up to 6900mm.
GIWL 48 I 50 PIR (A) (EN)
One layer of Gyproc ThermaLine PIR 38mm to one side of Gypframe 48 I 50 ‘I’ Stud framework forming an independent lining to masonry background. For heights up to 2400mm.
GIWL 60 I 50 PIR (A) (EN)
One layer of Gyproc ThermaLine PIR 38mm to one side of Gypframe 60 I 50 ‘I’ Stud framework forming an independent lining to masonry background. For heights up to 2400mm.
GIWL 60 I 70 PIR (EN)
One layer of Gyproc ThermaLine PIR 38mm to one side of Gypframe 60 I 70 ‘I’ Stud framework forming an independent lining to masonry background. For heights up to 3000mm.
GIWL 70 I 70 PIR (EN)
One layer of Gyproc ThermaLine PIR 38mm to one side of Gypframe 70 I 70 ‘I’ Stud framework forming an independent lining to masonry background. For heights up to 3600mm.
GIWL 92 I 90 PIR (A) (EN)
One layer of Gyproc ThermaLine PIR 38mm to one side of Gypframe 92 I 90 ‘I’ Stud framework forming an independent lining to masonry background. For heights up to 4200mm.
GIWL 92 I 90 PIR (B) (EN)
One layer of Gyproc ThermaLine PIR 38mm to one side of Gypframe 92 I 90 ‘I’ Stud framework forming an independent lining to masonry background. For heights up to 5100mm.
RF-PIR (A) (EN)
One layer of Gyproc ThermaLine PIR 38mm on Gyproc Sealant (3mm nominal cavity) on existing plastered walls, level brick, block or fair faced concrete.
-