Steel Protection
Assured level of fire protection to structural steelwork
British Gypsum steel protection specifications give an assured level of fire protection to structural steel. They present high quality claddings with or without supplementary framing. They employ either direct board to board fixing or are based on the lightweight steel framework clad with fire protective boards and are fully compatible with lightweight partitions, wall linings and ceiling systems.
Watch this short video to see how to use this EN Specification Selector and where you can still get details of our BS Specifications.
D120001 (A) (EN)
One layer of Glasroc F FireCase 15mm providing 30 minutes fire protection to steel columns up to a Section Factor A/V (HP/A) m-1 (max) of 260.
D120001 (B) (EN)
One layer of Glasroc F FireCase 15mm providing 30 minutes fire protection to steel beams up to a Section Factor A/V (HP/A) m-1 (max) of 260.
D120001 (C) (EN)
One layer of Glasroc F FireCase 15mm providing 60 minutes fire protection to steel columns up to a Section Factor A/V (HP/A) m-1 (max) of 232.
D120001 (D) (EN)
One layer of Glasroc F FireCase 15mm providing 60 minutes fire protection to steel beams up to a Section Factor A/V (HP/A) m-1 (max) of 129.
D120001 (E) (EN)
One layer of Glasroc F FireCase 15mm providing 90 minutes fire protection to steel columns up to a Section Factor A/V (HP/A) m-1 (max) of 98.
D120001 (F) (EN)
One layer of Glasroc F FireCase 15mm providing 90 minutes fire protection to steel beams up to a Section Factor A/V (HP/A) m-1 (max) of 63.
D120001 (P) (EN)
Inner layer of Glasroc F FireCase 15mm and outer layer of Glasroc F FireCase 20mm providing 90 minutes fire protection to steel beams up to a Section Factor A/V (HP/A) m-1 (max) of 260.
D120001 (T) (EN)
Inner layer of Glasroc F FireCase 15mm and outer layer of Glasroc F FireCase 20mm providing 120 minutes fire protection to steel beams up to a Section Factor A/V (HP/A) m-1 (max) of 69.
D120001 (U) (EN)
One layer of Glasroc F FireCase 15mm providing 120 minutes fire protection to steel columns up to a Section Factor A/V (HP/A) m-1 (max) of 62.