British Gypsum UK

Steel Protection

Assured level of fire protection to structural steelwork

British Gypsum steel protection specifications give an assured level of fire protection to structural steel. They present high quality claddings with or without supplementary framing. They employ either direct board to board fixing or are based on the lightweight steel framework clad with fire protective boards and are fully compatible with lightweight partitions, wall linings and ceiling systems.

 

 

Watch this short video to see how to use this EN Specification Selector and where you can still get details of our BS Specifications.

Filter your results
Apply filters
Filter
Fire Protection (mins)
min
max
Maximum Section Factor (m-1)
min
max
Products used
6 Solutions

D120004 (C) (EN)

One layer of Glasroc F FireCase 25mm providing 60 minutes fire protection to castellated steel beams up to a Section Factor A/V (HP/A) m-1 (max) of 148 at a critical temperature of 450oC. Claims compliant with Yellow Book 5th Edition 20% rule (YB4.2) assessment method.

Framed / Frameless
Frameless
Fire Protection (mins)
60
Maximum Section Factor (m-1)
148

D120004 (E) (EN)

One layer of Glasroc F FireCase 25mm providing 90 minutes fire protection to castellated steel beams up to a Section Factor A/V (HP/A) m-1 (max) of 60 at a critical temperature of 450oC. Claims compliant with Yellow Book 5th Edition 20% rule (YB4.2) assessment method.

Framed / Frameless
Frameless
Fire Protection (mins)
90
Maximum Section Factor (m-1)
60