Image

Shaftwall

Shaft and duct encasement system

ShaftWall provides a lightweight, fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an early stage of the construction without the need for scaffolding. The system can also be built horizontally to provide a fire rated membrane.

Please note that all British Gypsum Drylining systems are tested to the BS EN fire test standard. However we can continue to support your BS Standard Specifications project with remaining test evidence to BS 476. Please click here for more information.

 

Watch this short video to see how to use this EN Specification Selector and where you can still get details of our BS Specifications.

Filter your results
Apply filters
Filter
Fire Integrity (mins)
min
max
Fire Insulation (mins)
min
max
Sound Insulation (Airborne) Rw (dB)
min
max
Maximum Height (mm)
min
max
Partition Thickness (mm)
min
max
Products used
32 Solutions

A306003 (A) MR1 (EN)

Gypframe 60 I 70 ‘I’ Studs at 600mm centres with Gyproc CoreBoard 19mm between studs, secured by Gypframe G102 Retaining Channel. Inner layer of Gyproc FireLine 15mm with an outer layer of Gyproc FireLine MR 15mm to non-shaft side. For heights up to 4200mm.

Fire Integrity (mins)
90
Fire Insulation (mins)
90
Sound Insulation (Airborne) Rw (dB)
42
Duty Rating
Severe
Maximum Height (mm)
4200
Partition Thickness (mm)
92

A306003 (B) MR1 (EN)

Gypframe 60 I 70 ‘I’ Studs at 600mm centres with Gyproc CoreBoard 19mm between studs, secured by Gypframe G102 Retaining Channel. Inner layer of Gyproc FireLine 15mm with an outer layer of Gyproc FireLine MR 15mm to non-shaft side. For heights up to 4500mm.

Fire Integrity (mins)
90
Fire Insulation (mins)
90
Sound Insulation (Airborne) Rw (dB)
42
Duty Rating
Severe
Maximum Height (mm)
4500
Partition Thickness (mm)
92

A306006 (A) MR1 (EN)

Gypframe 92 I 90 ‘I’ Studs at 600mm centres with Gyproc CoreBoard 19mm between studs, secured by Gypframe G105 Retaining Channel. Inner layer of Gyproc FireLine 15mm with an outer layer of Gyproc FireLine MR 15mm to non-shaft side. For heights up to 4200mm.

Fire Integrity (mins)
90
Fire Insulation (mins)
90
Sound Insulation (Airborne) Rw (dB)
44
Duty Rating
Severe
Maximum Height (mm)
4200
Partition Thickness (mm)
124

A306006 (B) MR1 (EN)

Gypframe 92 I 90 ‘I’ Studs at 600mm centres with Gyproc CoreBoard 19mm between studs, secured by Gypframe G105 Retaining Channel. Inner layer of Gyproc FireLine 15mm with an outer layer of Gyproc FireLine MR 15mm to non-shaft side. For heights up to 6000mm.

Fire Integrity (mins)
90
Fire Insulation (mins)
90
Sound Insulation (Airborne) Rw (dB)
44
Duty Rating
Severe
Maximum Height (mm)
6000
Partition Thickness (mm)
124

A306009 (A) MR1 (EN)

Gypframe 146 TI 90 Tabbed ‘I’ Studs at 600mm centres with Gyproc CoreBoard 19mm between studs, secured by Gypframe G102 Retaining Channel. Inner layer of Gyproc FireLine 15mm with an outer layer of Gyproc FireLine MR 15mm to non-shaft side. For heights up to 4200mm.

Fire Integrity (mins)
90
Fire Insulation (mins)
90
Sound Insulation (Airborne) Rw (dB)
48
Duty Rating
Severe
Maximum Height (mm)
4200
Partition Thickness (mm)
178

A306009 (B) MR1 (EN)

Gypframe 146 TI 90 Tabbed ‘I’ Studs at 600mm centres with Gyproc CoreBoard 19mm between studs, secured by Gypframe G102 Retaining Channel. Inner layer of Gyproc FireLine 15mm with an outer layer of Gyproc FireLine MR 15mm to non-shaft side. For heights up to 6000mm.

Fire Integrity (mins)
90
Fire Insulation (mins)
90
Sound Insulation (Airborne) Rw (dB)
48
Duty Rating
Severe
Maximum Height (mm)
6000
Partition Thickness (mm)
178

A306023 (A) MR1 (EN)

Gypframe 60 I 70 ‘I’ Studs at 600mm centres with Gyproc CoreBoard 19mm between studs, secured by Gypframe G102 Retaining Channel. Inner layer of Gyproc FireLine 15mm with an outer layer of Gyproc FireLine MR 15mm to non-shaft side and 25mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 4200mm.

Fire Integrity (mins)
90
Fire Insulation (mins)
90
Sound Insulation (Airborne) Rw (dB)
45
Duty Rating
Severe
Maximum Height (mm)
4200
Partition Thickness (mm)
92

A306023 (B) MR1 (EN)

Gypframe 60 I 70 ‘I’ Studs at 600mm centres with Gyproc CoreBoard 19mm between studs, secured by Gypframe G102 Retaining Channel. Inner layer of Gyproc FireLine 15mm with an outer layer of Gyproc FireLine MR 15mm to non-shaft side and 25mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 4500mm.

Fire Integrity (mins)
90
Fire Insulation (mins)
90
Sound Insulation (Airborne) Rw (dB)
45
Duty Rating
Severe
Maximum Height (mm)
4500
Partition Thickness (mm)
92

A306025 (A) MR1 (EN)

Gypframe 92 I 90 ‘I’ Studs at 600mm centres with Gyproc CoreBoard 19mm between studs, secured by Gypframe G105 Retaining Channel. Inner layer of Gyproc FireLine 15mm with an outer layer of Gyproc FireLine MR 15mm to non-shaft side and 25mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 4200mm.

Fire Integrity (mins)
90
Fire Insulation (mins)
90
Sound Insulation (Airborne) Rw (dB)
46
Duty Rating
Severe
Maximum Height (mm)
4200
Partition Thickness (mm)
124