Shaftwall
Shaft and duct encasement system
ShaftWall provides a lightweight, fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an early stage of the construction without the need for scaffolding. The system can also be built horizontally to provide a fire rated membrane.
Please note that all British Gypsum Drylining systems are tested to the BS EN fire test standard. However we can continue to support your BS Standard Specifications project with remaining test evidence to BS 476. Please click here for more information.
To see all Specifications that use a particular Product, please go to the Product page and look for the ‘Show me all specifications that use this product’ option.
To see all Specifications for a particular System, please go to the System page and look for the ‘Show all specifications for this system’ option.
Watch this short video to see how to use this EN Specification Selector and where you can still get details of our BS Specifications.
Specification Sort descending | Partition Thickness (mm) | Fire Integrity (mins) | Fire Insulation (mins) | Sound Insulation (Airborne) Rw (dB) | Maximum Height (mm) | Duty Rating |
---|---|---|---|---|---|---|
A306002 (A) (EN) | 87 | 60 | 60 | 40 | 4200 | Severe |
A306002 (B) (EN) | 87 | 60 | 60 | 40 | 4400 | Severe |
A306003 (A) (EN) | 92 | 90 | 90 | 42 | 4200 | Severe |
A306003 (B) (EN) | 92 | 90 | 90 | 42 | 4500 | Severe |
A306005 (A) (EN) | 119 | 60 | 60 | 45 | 4200 | Severe |
A306005 (B) (EN) | 119 | 60 | 60 | 45 | 6000 | Severe |
A306006 (A) (EN) | 124 | 90 | 90 | 44 | 4200 | Severe |
A306006 (B) (EN) | 124 | 90 | 90 | 44 | 6000 | Severe |
A306008 (A) (EN) | 173 | 60 | 60 | 48 | 4200 | Severe |