Internal Partitions & Walls
A full range of lightweight partition systems
British Gypsum offers a full range of lightweight partition and walling systems. Standard systems are non-loadbearing and constructed using drylining techniques. British Gypsum metal framed partitions and walls can be used in all types of buildings including private housing, flats and apartments, commercial, institutional, recreational and industrial properties. They cover all applications, from simple space division through to high performance walls designed to meet the most demanding fire resistance, sound insulation, impact and height requirements.
Please note that all British Gypsum Drylining systems are tested to the BS EN fire test standard. However we can continue to support your BS Standard Specifications project with remaining test evidence to BS 476. Please click here for more information.
Watch this short video to see how to use this EN Specification Selector and where you can still get details of our BS Specifications.
- Gypframe 50 FEC 50 Folded Edge Standard Floor & Ceiling Channel (6)
- Gypframe 72 DC 60 Deep Flange Floor & Ceiling Channel (4)
- Gypframe 72 FEC 50 Folded Edge Standard Floor & Ceiling Channel (21)
- Gypframe 94 FEC 50 Folded Edge Standard Floor & Ceiling Channel (12)
- Gypframe 148 DC 60 Deep Flange Floor & Ceiling Channel (4)
- Gypframe 148 FEC 50 Folded Edge Standard Floor & Ceiling Channel (16)
A206067A (EN)
Two layers of Gyproc FireLine 12.5mm each side of Gypframe 48 S 50 'C' Studs at 600mm centres. For heights up to 3400mm.
A206067A MR1 (EN)
Two layers of Gyproc FireLine 12.5mm one side and an inner layer of Gyproc FireLine 12.5mm and an outer layer of Gyproc FireLine MR 12.5mm the other side of Gypframe 48 S 50 'C' Studs at 600mm centres. For heights up to 3400mm.
A206067A MR2 (EN)
Inner layer of Gyproc FireLine 12.5mm and an outer layer of Gyproc FireLine MR 12.5mm each side of Gypframe 48 S 50 'C' Studs at 600mm centres. For heights up to 3400mm.
A206079 (EN)
Two layers of Gyproc FireLine 12.5mm each side of Gypframe 70 S 50 'C' Studs at 600mm centres. For heights up to 4200mm.
A206079 MR1 (EN)
Two layers of Gyproc FireLine 12.5mm one side and an inner layer of Gyproc FireLine 12.5mm and an outer layer of Gyproc FireLine MR 12.5mm the other side of Gypframe 70 S 50 'C' Studs at 600mm centres. For heights up to 4200mm.
A206079 MR2 (EN)
Inner layer of Gyproc FireLine 12.5mm and an outer layer of Gyproc FireLine MR 12.5mm each side of Gypframe 70 S 50 'C' Studs at 600mm centres. For heights up to 4200mm.
A206091 (EN)
Two layers of Gyproc FireLine 12.5mm each side of Gypframe 146 S 50 'C' Studs at 600mm centres. For heights up to 4200mm.
A206091 MR1 (EN)
Two layers of Gyproc FireLine 12.5mm one side and an inner layer of Gyproc FireLine 12.5mm and an outer layer of Gyproc FireLine MR 12.5mm the other side of Gypframe 146 S 50 'C' Studs at 600mm centres. For heights up to 4200mm.
A206091 MR2 (EN)
Inner layer of Gyproc FireLine 12.5mm and an outer layer of Gyproc FireLine MR 12.5mm each side of Gypframe 146 S 50 'C' Studs at 600mm centres. For heights up to 4200mm.