Skip to main content
toggle menu
Home
User account menu
  • Products
  • White Book Specification Selector
  • Log in / Register
Main navigation
  • Inspiration
    Building Better
    • Project Showcase
    Learn more
    Thought Leadership
    • Thought Leadership Articles
    • Thought Leaders
    Learn more
    The Build Better Centre
    Learn more
  • Specification
    White Book Specification Selector
    • White Book Overview
    • Ceilings
    • External Walls
    • Floors
    • Horizontal ShaftWall
    • Internal Partitions & Walls
    • Shaftwall
    • Steel Protection
    • Thistle Plaster Systems
    • Wall Linings
    • BS Specifications
      Display in two columns
      Off
    Learn more
    Our Products
    • Acoustic ceiling systems
    • British Gypsum fixings
    • Gypframe
    • Gyproc jointing products
    • Gyproc plasterboards
    • Thistle plasters
    Learn more
    Resources and Literature
    • All literature
    • Declaration of Performance
    • Product Data Sheets
    • Safety Data Sheets
    • Environmental Product Declarations
    Learn more
    SpecSure® System Warranty
    Learn more
  • Installation
    Our Products
    • Acoustic ceiling systems
    • British Gypsum fixings
    • Gypframe
    • Gyproc jointing products
    • Gyproc plasterboards
    • Thistle plasters
    Learn more
    The Plasterer’s Hub
    • Join the Certified Plasterer Scheme
    • Find a Certified Plasterer
    Learn more
    Installation Guidance and Support
    • Installation Guides
    • Product, project and training support
    Learn more
    Stockist Locator
    Learn more
  • Skills Development
    Upskilling Courses
    • Book a course
    • Training Prospectus
      Display in two columns
      Off
      Background color
      Grey
    • Training Academies
    Learn more
    Students, Apprentices and New Trainees
    • Partnership Colleges
    Learn more
    E-Learning
    • Our Platform and Courses
    Learn more
    CPD Resource
    • Acoustic Design
      Display in two columns
      Off
      Last item
      Désactivé
    • Inhibiting Fire Growth
    • System Integrity
      Display in two columns
      Off
      Last item
      Désactivé
    Learn more
  • Technical Support
    Self Help Tools
    • FAQs
    • Plaster Coverage Calculator
    • Thermal Calculator
    • Design Guidance
    • Resources and Literature
    Learn more
    Technical Consultancy
    • Technical Enquiry Form
    Learn more
    SpecSure® System Warranty
    Learn more
  • Customer Services
    Services
    • Distribution Innovation
    • Track and Trace
    Learn more
Search
Breadcrumb
  1. Home
  2. Specification
  3. White Book Specification Selector
  4. Internal Partitions & Walls
  5. GypWall Twin Frame Independent
  6. L216015 (EN)
Help menu
Last reviewed:
22.09.2021
Last updated:
23.06.2023
Image
Share
Email Facebook Twitter Linkedin
Print
Bookmark this page
Download
GypWall Twin Frame Independent

L216015 (EN)

Inner layer of Gyproc SoundBloc F 15mm with an outer layer of Gyproc Habito 12.5mm fixed to outside faces of two Gypframe 48 I 50 ‘I’ Stud frameworks with studs at 600mm centres. 50mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 2800mm.

Read more
Read less
Fire Integrity (mins)
120
Fire Insulation (mins)
120
Sound Insulation (Airborne) Rw (dB)
65
Sound Insulation (Airborne) Rw + Ctr (dB)
57
Duty Rating
Severe
Maximum Height (mm)
2800
Partition Thickness (mm)
200
Add to project
L216015 (EN)
Share
Email Facebook Twitter Linkedin
Print
Add to project
  • Description
  • Standards
  • Products
  • Details
  • Documents
  • Test Reports
  • Installation
  • Related Case Studies

Standards

Standards Standard types
StandardsBS EN ISO 10140-2,Acoustics - Laboratory measurement of sound insulation of building elements. Measurement of airborne sound insulation. Standard types
StandardsBS 5234-2,Specification for performance requirements for strength and robustness including methods of test. Standard types
StandardsBS EN 1364-1,Fire resistance tests for non-loadbearing elements - Walls. Standard types

Products

Abutments and openings Gypframe 48 S 50 'C' Stud
Fixing strap Gypframe GFS1 Fixing Strap
Base channel Gypframe 50 FEC 50 Folded Edge Standard Floor & Ceiling Channel
Head channel Gypframe 50 FEC 50 Folded Edge Standard Floor & Ceiling Channel
Stud Gypframe 48 I 50 'I' Stud
Screws side 1 Layer 1: British Gypsum Drywall Screws 25mm
Layer 2: British Gypsum High Performance Screws 40mm
Screws side 2 Layer 1: British Gypsum Drywall Screws 25mm
Layer 2: British Gypsum High Performance Screws 40mm
Board side 1 Layer 1: Gyproc SoundBloc F 15mm
Layer 2: Gyproc Habito 12.5mm
Board side 2 Layer 1: Gyproc SoundBloc F 15mm
Layer 2: Gyproc Habito 12.5mm
Sealant Gyproc Sealant
Insulation Layer 1: 50mm Isover Acoustic Partition Roll (APR 1200)

Details

This section should be read in conjunction with the Products list.

  • Abutment Fixing: Two rows of Gypframe 'C' stud suitably fixed to structure at 600mm centres.
  • Base Channel Fixing: Two rows of Gypframe channel suitably fixed to floor at 600mm centres.
  • Deflection Allowance: Vertical deflection only. To be determined by a Structural Engineer.
  • Dropped Soffit: For principles of deflection head construction refer to detail ST‐126‐Z2L2‐09.
  • Finishing Requirements: To achieve the specified performances, the system should be finished using Gyproc jointing products. See the product range guides on the British Gypsum website for more information.
  • Fixing Strap: Used to support horizontal board joints in face layer of multiple layer board linings and enable board screw fixing at 300mm centres.
  • Loadbearing: No
  • Maximum Height: The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the lower of the two.
  • Other Requirements: SpecSure® system performance warranty confirms that British Gypsum proprietary systems will perform as specified for the lifetime of the building. The SpecSure® warranty requires that all components are specified in full and constructed in accordance with British Gypsum’s installation guidance. For more details see the British Gypsum website. Always check with the design team before making any changes to the chosen specification, ensuring appropriate substantiation is sought to confirm that the solution still meets all required project performances.
  • Screw: Board layer 1 (inner), fix securely to Gypframe metal supports around the perimeter of the board at maximum 300mm centres; Board layer 2 (outer), fix securely to all Gypframe metal supports around the perimeter of the board and intermediate stud positions at maximum 300mm centres. External corners reduce fixings to 200mm. All joints staggered between layers. Fix working from the centre of each board. Position screws not less than 13mm from cut edges and 10mm from bound edges of boards. Set screw heads flush with plasterboard surface; do not break paper or gypsum core.
  • Sealant: Locate sealant at junctions with adjoining structure and other air paths. Apply as a continuous bead to clean, dry, dust-free surfaces, leaving no gaps. After application of sealant, bulk fill gaps between floor and underside of plasterboard using Gyproc joint compound.
  • Stud: Two rows of Gypframe studs arranged in pairs.
  • Stud Centres (mm): 600 mm
  • Approx. Weight (kg/m2): 56 kg/m²
  • Head Channel Fixing: Two rows of Gypframe channel suitably fixed to soffit at 600mm centres.

Documents

Select all
BIM files
2 datasheets related with the system
2 datasheets related with the system
British-Gypsum-BIM-L216015-(EN).rvt
BIM files
.rvt | 2.73 MB
British-Gypsum-BIM-Material-File.adsklib
BIM files
.adsklib | 2.59 MB
CAD details (PDF)
1 datasheet related with the system
1 datasheet related with the system
British-Gypsum-GypWall-Twin-Frame-Independent-EN-90-or-120-minutes-I-stud-2-layers-Set.pdf
CAD details (PDF)
.pdf | 1.40 MB
View
Download
Technical Specification
1 datasheet related with the system
1 datasheet related with the system
British-Gypsum-TS-L216015-(EN).pdf
Technical Specification
.pdf | 244.12 KB
Certificates
1 datasheet related with the system
1 datasheet related with the system
BSI - BES 6001
Certificates
.pdf | 1.01 MB
View
Download
Test reports
3 datasheets related with the system
3 datasheets related with the system
BTC 20740F.pdf
Test reports
.pdf | 1.86 MB
BTC 20785A.pdf
Test reports
.pdf | 440.86 KB
BTC 20786LC.pdf
Test reports
.pdf | 1.58 MB
Construction details (.dwg)
4 datasheets related with the system
4 datasheets related with the system
CN-126-002-GWTFI-def-head-para-perp-profile-soffit-2-layers-EN-90-or-120-minutes.dwg
Construction details (.dwg)
.dwg | 154.87 KB
CN-126-004-GWTFI-def-head-para-perp-dovetail-soffit-2-layers-EN-90-or-120-minutes.dwg
Construction details (.dwg)
.dwg | 155.69 KB
CN-623-005-socket-box-baffle-2-layers-EN-120-minutes.dwg
Construction details (.dwg)
.dwg | 146.18 KB
CN-624-001-GypWall-systems-opening-width-up-to-1200mm.dwg
Construction details (.dwg)
.dwg | 108.63 KB
Construction details (PDF)
4 datasheets related with the system
4 datasheets related with the system
CN-126-002-GWTFI-def-head-para-perp-profile-soffit-2-layers-EN-90-or-120-minutes.pdf
Construction details (PDF)
.pdf | 340.80 KB
View
Download
CN-126-004-GWTFI-def-head-para-perp-dovetail-soffit-2-layers-EN-90-or-120-minutes.pdf
Construction details (PDF)
.pdf | 340.59 KB
View
Download
CN-623-005-socket-box-baffle-2-layers-EN-120-minutes.pdf
Construction details (PDF)
.pdf | 350.15 KB
View
Download
CN-624-001-GypWall-systems-opening-width-up-to-1200mm.pdf
Construction details (PDF)
.pdf | 273.54 KB
View
Download
Declaration Of Performance (DoP)
12 datasheets related with the system
12 datasheets related with the system
DoP - 0007-CPR UK - Isover Acoustic Partition Roll (APR 1200)
Declaration Of Performance (DoP)
.pdf | 75.35 KB
View
Download
DoP - BOARD128 - Gyproc SoundBloc F
Declaration Of Performance (DoP)
.pdf | 141.59 KB
View
Download
DoP - BOARD128 UK - Gyproc SoundBloc F
Declaration Of Performance (DoP)
.pdf | 83.23 KB
View
Download
DoP - BOARD133 - Gyproc Habito
Declaration Of Performance (DoP)
.pdf | 142.03 KB
View
Download
DoP - BOARD133 UK - Gyproc Habito
Declaration Of Performance (DoP)
.pdf | 105.43 KB
View
Download
DoP - FIX100 - British Gypsum Screws
Declaration Of Performance (DoP)
.pdf | 121.11 KB
View
Download
DoP - FIX100 UK - British Gypsum Screws
Declaration Of Performance (DoP)
.pdf | 99.67 KB
View
Download
DoP - M100 - Gypframe Metal Profiles
Declaration Of Performance (DoP)
.pdf | 124.49 KB
View
Download
DoP - M100 UK - Gypframe Metal Profiles
Declaration Of Performance (DoP)
.pdf | 93.55 KB
View
Download
DoP - SEAL100 - Gyproc Sealant (5015341270970)
Declaration Of Performance (DoP)
.pdf | 107.40 KB
View
Download
DoP - SEAL100 UK - Gyproc Sealant (5015341270970)
Declaration Of Performance (DoP)
.pdf | 95.03 KB
View
Download
DoP-CE-0007-CPR-Isover_Acoustic-Partition-Roll-APR-1200.pdf
Declaration Of Performance (DoP)
.pdf | 62.44 KB
View
Download
Environmental Product Declaration (EPD)
1 datasheet related with the system
1 datasheet related with the system
EPD - Gypframe metal framing components
Environmental Product Declaration (EPD)
.pdf | 1.57 MB
View
Download
Safety Data Sheet (SDS)
6 datasheets related with the system
6 datasheets related with the system
Isover Safe Use Instruction Sheet
Safety Data Sheet (SDS)
.pdf | 50.57 KB
View
Download
SDS - British Gypsum fixings
Safety Data Sheet (SDS)
.pdf | 517.14 KB
View
Download
SDS - Gypframe metal products
Safety Data Sheet (SDS)
.pdf | 658.56 KB
View
Download
SDS - Gyproc Habito
Safety Data Sheet (SDS)
.pdf | 481.38 KB
View
Download
SDS - Gyproc Sealant
Safety Data Sheet (SDS)
.pdf | 513.23 KB
View
Download
SDS - Gyproc SoundBloc F
Safety Data Sheet (SDS)
.pdf | 466.12 KB
View
Download
Product Data Sheet (PDS)
10 datasheets related with the system
10 datasheets related with the system
PDS - Drywall Screws 25mm
Product Data Sheet (PDS)
.pdf | 163.17 KB
View
Download
PDS - Gypframe 48 I 50 'I' Stud
Product Data Sheet (PDS)
.pdf | 226.97 KB
View
Download
PDS - Gypframe 48 S 50 'C' Stud
Product Data Sheet (PDS)
.pdf | 194.47 KB
View
Download
PDS - Gypframe 50 FEC 50 Folded Edge Standard Floor & Ceiling Channel
Product Data Sheet (PDS)
.pdf | 206.52 KB
View
Download
PDS - Gypframe GFS1 Fixing Strap
Product Data Sheet (PDS)
.pdf | 204.65 KB
View
Download
PDS - Gyproc Habito 12.5mm
Product Data Sheet (PDS)
.pdf | 141.96 KB
View
Download
PDS - Gyproc Sealant
Product Data Sheet (PDS)
.pdf | 234.22 KB
View
Download
PDS - Gyproc SoundBloc F 15mm
Product Data Sheet (PDS)
.pdf | 139.38 KB
View
Download
PDS - High Performance Screws 40mm
Product Data Sheet (PDS)
.pdf | 182.57 KB
View
Download
PDS - Isover Acoustic Partition Roll (APR 1200)
Product Data Sheet (PDS)
.pdf | 132.55 KB
View
Download
Product selector guide
1 datasheet related with the system
1 datasheet related with the system
Selector Guide - Plasterboard
Product selector guide
.pdf | 667.77 KB
View
Download
CAD details (.dwg)
6 datasheets related with the system
6 datasheets related with the system
ST-126-Z2L2-01-base-horiz-brd-joint-and-wall-abutment.dwg
CAD details (.dwg)
.dwg | 124.33 KB
ST-126-Z2L2-02-corner-and-splayed-angle.dwg
CAD details (.dwg)
.dwg | 129.90 KB
ST-126-Z2L2-03-T-junctions.dwg
CAD details (.dwg)
.dwg | 128.34 KB
ST-126-Z2L2-04 door opening heavy severe.dwg
CAD details (.dwg)
.dwg | 132.59 KB
ST-126-Z2L2-05-head.dwg
CAD details (.dwg)
.dwg | 109.01 KB
ST-126-Z2L2-09-def-head-EN-90-or-120-minutes.dwg
CAD details (.dwg)
.dwg | 139.75 KB
White Book
3 datasheets related with the system
3 datasheets related with the system
White Book - Finishes
White Book
.pdf | 18.29 MB
View
Download
White Book - GypWall Twin Frame Independent
White Book
.pdf | 10.48 MB
View
Download
White Book - System design principles
White Book
.pdf | 3.59 MB
View
Download

Our website ALWAYS carries the latest and most up to date version of all of these documents, but on occasion there is a need for previous versions. If you do require a previous version of documents related to the products that make up this specification click here

Need CAD, BIM, Test Reports and Technical Specifications?

Log in to access CAD .dwg files.

Log in and add a System Specification to a Project to access BIM files, Test Reports, and Technical Specification files.

login

Test Reports

Please add this Specification to a project and go to that Project to access the related Test Reports.

Test report label Test report name
Test report labelFire Resistance Test Report Test report nameBTC 20740F
Test report labelSound Insulation Test Report Test report nameBTC 20785A
Test report labelPartition Duty Test Report Test report nameBTC 20786LC
Image
The White Book Specification Selector
Find system specifications that match your needs
Show all specifications
British Gypsum UK

SpecSure

A unique warranty that confirms British Gypsum proprietary systems will perform as specified for the lifetime of the building.

Learn more
Facebook
Twitter
Youtube
LinkedIn
Instagram
Footer left menu
  • About Us
  • Sustainability
  • Building Better Communities
  • Corporate Governance
  • Careers
  • Cookie Policy
  • Privacy Policy
Saint-Gobain

Saint-Gobain Construction Products UK Limited trading as British Gypsum. Registered Office Saint-Gobain House, East Leake, Loughborough, Leicestershire. LE12 6JU.
Company Number 00734396. VAT No: GB 438 3065 50

© Saint-Gobain Construction Products UK Limited 2022. All rights reserved.

  • Product
  • Specification
Compare
Export the list in .csv
Compare