!*
Skip to main content
toggle menu
Home
User account menu
  • Products
  • White Book Specification Selector
  • Log in / Register
Main navigation
  • Inspiration
    Building Better
    • Project Showcase
    Learn more
    Thought Leadership
    • Thought Leadership Articles
    • Thought Leaders
    Learn more
    The Build Better Centre
    Learn more
  • Specification
    White Book Specification Selector
    • White Book Overview
    • Ceilings
    • External Walls
    • Floors
    • Horizontal ShaftWall
    • Internal Partitions & Walls
    • Shaftwall
    • Steel Protection
    • Thistle Plaster Systems
    • Wall Linings
    • BS Specifications
      Display in two columns
      Off
    Learn more
    Our Products
    • Acoustic ceiling systems
    • British Gypsum fixings
    • Gypframe
    • Gyproc jointing products
    • Gyproc plasterboards
    • Thistle plasters
    Learn more
    Resources and Literature
    • All literature
    • Declaration of Performance
    • Product Data Sheets
    • Safety Data Sheets
    • Environmental Product Declarations
    Learn more
    SpecSure® System Warranty
    Learn more
  • Installation
    Our Products
    • Acoustic ceiling systems
    • British Gypsum fixings
    • Gypframe
    • Gyproc jointing products
    • Gyproc plasterboards
    • Thistle plasters
    Learn more
    The Plasterer’s Hub
    • Join the Certified Plasterer Scheme
    • Find a Certified Plasterer
    Learn more
    Installation Guidance and Support
    • Installation Guides
    • Product, project and training support
    Learn more
    Stockist Locator
    Learn more
  • Skills Development
    Upskilling Courses
    • Book a course
    • Training Prospectus
      Display in two columns
      Off
      Background color
      Grey
    • Training Academies
    Learn more
    Students, Apprentices and New Trainees
    • Partnership Colleges
    • Students and Apprentices
    Learn more
    E-Learning
    • Our Platform and Courses
    Learn more
  • Technical Support
    Self Help Tools
    • FAQs
    • Plaster Coverage Calculator
    • Thermal Calculator
    • Design Guidance
    • Resources and Literature
    Learn more
    Technical Consultancy
    • Technical Enquiry Form
    Learn more
    SpecSure® System Warranty
    Learn more
  • Customer Services
    Services
    • Distribution Innovation
    • Track and Trace
    Learn more
Search
Breadcrumb
  1. Home
  2. Specification
  3. White Book Specification Selector
  4. Internal Partitions & Walls
  5. GypWall Single Frame
  6. A206252 (EN)
Help menu
Last reviewed:
22.09.2021
Last updated:
17.08.2022
Image
Share
Email Facebook Twitter Linkedin
Print
Bookmark this page
Download
GypWall Single Frame

A206252 (EN)

Three layers of Gyproc FireLine 15mm each side of Gypframe 70 S 50 'C' Studs at 600mm centres. For heights up to 4000mm.

Read more
Read less
Fire Integrity (mins)
180
Fire Insulation (mins)
180
Sound Insulation (Airborne) Rw (dB)
46
Duty Rating
Severe
Maximum Height (mm)
4000
Partition Thickness (mm)
162
Add to project
A206252 (EN)
Share
Email Facebook Twitter Linkedin
Print
Add to project
  • Description
  • Standards
  • Products
  • Details
  • Documents
  • Test Reports
  • Installation
  • Related Case Studies

Standards

Standards Standard types
StandardsBS 2750-3,Measurement of sound insulation in buildings and of building elements. Laboratory measurements of airborne sound insulation of building elements. Standard types
StandardsBS 5234-2,Specification for performance requirements for strength and robustness including methods of test. Standard types
StandardsBS EN 1364-1,Fire resistance tests for non-loadbearing elements - Walls. Standard types

Products

Fixing strap Gypframe GFS1 Fixing Strap
Base channel Gypframe 72 FEC 50 Folded Edge Standard Floor & Ceiling Channel
Head channel Gypframe 72 FEC 50 Folded Edge Standard Floor & Ceiling Channel
Stud Gypframe 70 S 50 'C' Stud
Screws side 1 Layer 1: British Gypsum Drywall Screws 25mm
Layer 2: British Gypsum Drywall Screws 40mm
Layer 3: British Gypsum Drywall Screws 55mm
Screws side 2 Layer 1: British Gypsum Drywall Screws 25mm
Layer 2: British Gypsum Drywall Screws 40mm
Layer 3: British Gypsum Drywall Screws 55mm
Sealant Gyproc Sealant
Board side 1 Layer 1: Gyproc FireLine 15mm
Layer 2: Gyproc FireLine 15mm
Layer 3: Gyproc FireLine 15mm
Board side 2 Layer 1: Gyproc FireLine 15mm
Layer 2: Gyproc FireLine 15mm
Layer 3: Gyproc FireLine 15mm

Details

This section should be read in conjunction with the Products list.

  • Abutment Fixing: Gypframe 'C' stud suitably fixed to structure at 600mm centres.
  • Base Channel Fixing: Gypframe channel suitably fixed to floor at 600mm centres.
  • Deflection Allowance: Vertical deflection only. To be determined by a Structural Engineer.
  • Dropped Soffit: For principles of deflection head construction refer to detail ST-121-Z1L3-11
  • Finishing Requirements: To achieve the specified performances, the system should be finished using either one of our Thistle or ThistlePro plasters, or Gyproc jointing products. See the product range guides on the British Gypsum website for more information.
  • Fixing Strap: Used to support horizontal board joints in face layer of multiple layer board linings and enable board screw fixing at 300mm centres.
  • Loadbearing: No
  • Maximum Height: The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the lower of the two.
  • Other Requirements: SpecSure® system performance warranty confirms that British Gypsum proprietary systems will perform as specified for the lifetime of the building. The SpecSure® warranty requires that all components are specified in full and constructed in accordance with British Gypsum’s installation guidance. For more details see the British Gypsum website. Always check with the design team before making any changes to the chosen specification, ensuring appropriate substantiation is sought to confirm that the solution still meets all required project performances.
  • Screw: Board layers 1 and 2 (inner), fix securely to Gypframe metal supports around the perimeter of the board at maximum 300mm centres; Board layer 3 (outer), fix securely to all Gypframe metal supports around the perimeter of the board and intermediate stud positions at maximum 300mm centres. External corners reduce fixings to 200mm. All joints staggered between layers. Fix working from the centre of each board. Position screws not less than 13mm from cut edges and 10mm from bound edges of boards. Set screw heads flush with plasterboard surface; do not break paper or gypsum core.
  • Sealant: Locate sealant at junctions with adjoining structure and other air paths. Apply as a continuous bead to clean, dry, dust-free surfaces, leaving no gaps. After application of sealant, bulk fill gaps between floor and underside of plasterboard using Gyproc joint compound.
  • Stud Centres (mm): 600 mm
  • Approx. Weight (kg/m2): 73 kg/m²
  • Head Channel Fixing: Gypframe channel suitably fixed to soffit at 600mm centres.

Documents

Select all
CAD details (PDF)
1 datasheet related with the system
1 datasheet related with the system
British-Gypsum-GypWall-Single-Frame-EN-180-minutes-C-stud-3-layers-stone-wool-Set.pdf
.pdf | 1.53 MB
View
Download
Certificates
1 datasheet related with the system
1 datasheet related with the system
BSI - BES 6001
.pdf | 772.38 KB
View
Download
Declaration Of Performance (DoP)
8 datasheets related with the system
8 datasheets related with the system
DoP - BOARD106 - Gyproc FireLine
.pdf | 159.02 KB
View
Download
DoP - BOARD106 UK - Gyproc FireLine
.pdf | 83.36 KB
View
Download
DoP - FIX100 - British Gypsum Screws
.pdf | 121.11 KB
View
Download
DoP - FIX100 UK - British Gypsum Screws
.pdf | 99.67 KB
View
Download
DoP - M100 - Gypframe Metal Profiles
.pdf | 124.49 KB
View
Download
DoP - M100 UK - Gypframe Metal Profiles
.pdf | 93.55 KB
View
Download
DoP - SEAL100 UK - Gyproc Sealant (5015341270970)
.pdf | 95.03 KB
View
Download
DoP - SEAL102 - Gyproc Sealant (5015341302152)
.pdf | 128.18 KB
View
Download
Environmental Product Declaration (EPD)
1 datasheet related with the system
1 datasheet related with the system
EPD - Gypframe metal framing components
.pdf | 1.57 MB
View
Download
Product Data Sheet (PDS)
8 datasheets related with the system
8 datasheets related with the system
PDS - Drywall Screws 25mm
.pdf | 163.17 KB
View
Download
PDS - Drywall Screws 40mm
.pdf | 178.33 KB
View
Download
PDS - Drywall Screws 55mm
.pdf | 192.74 KB
View
Download
PDS - Gypframe 70 S 50 'C' Stud
.pdf | 236.40 KB
View
Download
PDS - Gypframe 72 FEC 50 Folded Edge Standard Floor & Ceiling Channel
.pdf | 231.48 KB
View
Download
PDS - Gypframe GFS1 Fixing Strap
.pdf | 204.65 KB
View
Download
PDS - Gyproc FireLine 15mm
.pdf | 198.37 KB
View
Download
PDS - Gyproc Sealant
.pdf | 234.22 KB
View
Download
Safety Data Sheet (SDS)
4 datasheets related with the system
4 datasheets related with the system
SDS - British Gypsum fixings
.pdf | 517.14 KB
View
Download
SDS - Gypframe metal products
.pdf | 658.56 KB
View
Download
SDS - Gyproc FireLine
.pdf | 477.15 KB
View
Download
SDS - Gyproc Sealant
.pdf | 513.23 KB
View
Download
Product selector guide
1 datasheet related with the system
1 datasheet related with the system
Selector Guide - Plasterboard
.pdf | 667.77 KB
View
Download
CAD details (.dwg)
6 datasheets related with the system
6 datasheets related with the system
ST-121-Z1L3-01-base-horiz-brd-joint-and-wall-abutment.dwg
.dwg | 141.90 KB
ST-121-Z1L3-02-corner-and-splayed-angle.dwg
.dwg | 148.75 KB
ST-121-Z1L3-03-T-junctions.dwg
.dwg | 139.10 KB
ST-121-Z1L3-04-door-opening-heavy-severe.dwg
.dwg | 131.80 KB
ST-121-Z1L3-05-head.dwg
.dwg | 139.77 KB
ST-121-Z1L3-11-def-head-EN-180-minutes.dwg
.dwg | 159.70 KB
White Book
3 datasheets related with the system
3 datasheets related with the system
White Book - Finishes
.pdf | 18.28 MB
View
Download
White Book - GypWall Single Frame
.pdf | 11.63 MB
View
Download
White Book - System design principles
.pdf | 3.59 MB
View
Download

If you require previous versions of the documentation related to the products that make up this specification, please click here

Need CAD, BIM, Test Reports and Technical Specifications?

Log in to access CAD .dwg files.

Log in and add a System Specification to a Project to access BIM files, Test Reports, and Technical Specification files.

login

Test Reports

Please add this Specification to a project and go to that Project to access the related Test Reports.

Test report label Test report name
Test report labelFire Resistance Test Report Test report nameBTC 11310F
Test report labelSound Insulation Test Report Test report nameBTC 2965A
Test report labelPartition Duty Test Report Test report nameBTC 20341LC
Image
The White Book Specification Selector
Find system specifications that match your needs
Show all specifications
British Gypsum UK

SpecSure

A unique warranty that confirms British Gypsum proprietary systems will perform as specified for the lifetime of the building.

Learn more
Facebook
Twitter
Youtube
LinkedIn
Instagram
Footer left menu
  • About Us
  • Sustainability
  • Building Better Communities
  • Corporate Governance
  • Careers
  • Cookie Policy
  • Privacy Policy
Saint-Gobain

Saint-Gobain Construction Products UK Limited trading as British Gypsum. Registered Office Saint-Gobain House, East Leake, Loughborough, Leicestershire. LE12 6JU.
Company Number 00734396. VAT No: GB 438 3065 50

© Saint-Gobain Construction Products UK Limited 2022. All rights reserved.

  • Product
  • Specification
Compare
Export the list in .csv
Compare