!*
Skip to main content
toggle menu
Home
User account menu
  • Products
  • White Book Specification Selector
  • Log in / Register
Main navigation
  • Inspiration
    Building Better
    • Project Showcase
    Learn more
    Thought Leadership
    • Thought Leadership Articles
    • Thought Leaders
    Learn more
    The Build Better Centre
    Learn more
  • Specification
    White Book Specification Selector
    • White Book Overview
    • Ceilings
    • External Walls
    • Floors
    • Horizontal ShaftWall
    • Internal Partitions & Walls
    • Shaftwall
    • Steel Protection
    • Thistle Plaster Systems
    • Wall Linings
    • BS Specifications
      Display in two columns
      Off
    Learn more
    Our Products
    • Acoustic ceiling systems
    • British Gypsum fixings
    • Gypframe
    • Gyproc jointing products
    • Gyproc plasterboards
    • Thistle plasters
    Learn more
    Resources and Literature
    • All literature
    • Declaration of Performance
    • Product Data Sheets
    • Safety Data Sheets
    • Environmental Product Declarations
    Learn more
    SpecSure® System Warranty
    Learn more
  • Installation
    Our Products
    • Acoustic ceiling systems
    • British Gypsum fixings
    • Gypframe
    • Gyproc jointing products
    • Gyproc plasterboards
    • Thistle plasters
    Learn more
    The Plasterer’s Hub
    • Join the Certified Plasterer Scheme
    • Find a Certified Plasterer
    Learn more
    Installation Guidance and Support
    • Installation Guides
    • Product, project and training support
    Learn more
    Stockist Locator
    Learn more
  • Skills Development
    Upskilling Courses
    • Book a course
    • Training Prospectus
      Display in two columns
      Off
      Background color
      Grey
    • Training Academies
    Learn more
    Students, Apprentices and New Trainees
    • Partnership Colleges
    • Students and Apprentices
    Learn more
    E-Learning
    • Our Platform and Courses
    Learn more
  • Technical Support
    Self Help Tools
    • FAQs
    • Plaster Coverage Calculator
    • Thermal Calculator
    • Design Guidance
    • Resources and Literature
    Learn more
    Technical Consultancy
    • Technical Enquiry Form
    Learn more
    SpecSure® System Warranty
    Learn more
  • Customer Services
    Services
    • Distribution Innovation
    • Track and Trace
    Learn more
Search
Breadcrumb
  1. Home
  2. Specification
  3. White Book Specification Selector
  4. Ceilings
  5. GypCeiling Grid
  6. C10A150 (B) (EN)
Help menu
Last reviewed:
30.09.2021
Last updated:
30.09.2021
Image
Share
Email Facebook Twitter Linkedin
Print
Bookmark this page
Download
GypCeiling Grid

C10A150 (B) (EN)

GypCeiling Grid suspended ceiling system using CasoLine Quick-Lock Grid T24 Tees with a 300mm plenum depth incorporating a Gyptone Point 11 A tile with 75mm Isover Acoustic Slab in plenum.

Read more
Read less
Sound Absorption Coefficient (αw)
0.75
Edge Profile
A
Sound Absorption Class
C
Add to project
C10A150 (B) (EN)
Share
Email Facebook Twitter Linkedin
Print
Add to project
  • Description
  • Standards
  • Products
  • Details
  • Documents
  • Test Reports
  • Installation
  • Related Case Studies

Standards

Standards Standard types
StandardsBS EN ISO 354,Acoustics - Measurement of sound absorption in a reverberation room. Standard types

Products

Insulation Layer 1: 75mm Isover Acoustic Slab
Primary framework CasoLine Quick-Lock Grid Cross Tee (1200) 24/38
CasoLine Quick-Lock Grid Cross Tee (600) 24/38
CasoLine Quick-Lock Grid Main Tee 24/38
Suspension type CasoLine Quick-Lock Grid Hangers
Ceiling board Layer 1: Gyptone Point 11 A
Ceiling membrane Gyptone Point 11 A
Soffit connection Gypframe MF12 Soffit Cleat
Perimeter framing CasoLine Quick-Lock Grid Wall Angle WA03

Details

This section should be read in conjunction with the Products list.

  • Installation: To achieve a 600 x 600 grid the primary framing should be installed using CasoLine Quick-Lock Grid Main Tee 24/38 at 1200mm centres, CasoLine Quick-Lock Grid Cross Tee (1200) 24/38 at 600mm centres and CasoLine Quick-Lock Grid Cross Tee (600) 24/38 at 1200mm centres. All tees click together.
  • Loadbearing: No
  • Other Requirements: SpecSure® system performance warranty confirms that British Gypsum proprietary systems will perform as specified for the lifetime of the building. The SpecSure® warranty requires that all components are specified in full and constructed in accordance with British Gypsum’s installation guidance. For more details see the British Gypsum website. Always check with the design team before making any changes to the chosen specification, ensuring appropriate substantiation is sought to confirm that the solution still meets all required project performances.
  • Perimeter Framing: Perimeter framing should be suitably fixed to the wall at 300mm centres (maximum 50mm in from a corner). All corners should be mitred.
  • Structural Background: Concrete
  • Maximum Cavity / Plenum (mm): 2010 mm
  • Minimum Cavity / Plenum (mm): 300 mm
  • Suspension Type: Suspend ceiling using grid hangers with an appropriate size for the required plenum, secured to soffit cleat via hook. Alternatively, suspension wire (min. 14 swg by others) secured to soffit using fixings recommended by suspended ceiling contractor.
  • Suspension Type Centres (mm): 1200 mm

Documents

Select all
CAD details (PDF)
1 datasheet related with the system
1 datasheet related with the system
British-Gypsum-GypCeiling-Grid-ZZAA-tile-edge-A-Set.pdf
.pdf | 568.00 KB
View
Download
Declaration Of Performance (DoP)
4 datasheets related with the system
4 datasheets related with the system
DoP - CEILING202 - CasoLine Quick-Lock Grid T24
.pdf | 149.86 KB
View
Download
DoP - CEILING203 - CasoLine Quick-Lock Grid wall angles
.pdf | 148.75 KB
View
Download
DoP - CEILING204 - CasoLine Quick-Lock Grid hangers
.pdf | 147.64 KB
View
Download
DoP - GYP14190 - Gyptone Tiles
.pdf | 116.74 KB
View
Download
Product Data Sheet (PDS)
7 datasheets related with the system
7 datasheets related with the system
PDS - CasoLine Quick-Lock Grid Cross Tee (1200) 24/38
.pdf | 155.60 KB
View
Download
PDS - CasoLine Quick-Lock Grid Cross Tee (600) 24/38
.pdf | 157.22 KB
View
Download
PDS - CasoLine Quick-Lock Grid Hangers
.pdf | 148.66 KB
View
Download
PDS - CasoLine Quick-Lock Grid Main Tee 24/38
.pdf | 211.40 KB
View
Download
PDS - CasoLine Quick-Lock Grid Wall Angle WA03
.pdf | 154.06 KB
View
Download
PDS - Gypframe MF12 Soffit Cleat
.pdf | 207.34 KB
View
Download
PDS - Gyptone Point 11 A
.pdf | 218.65 KB
View
Download
Safety Data Sheet (SDS)
3 datasheets related with the system
3 datasheets related with the system
SDS - CasoLine Quick-Lock Grid ceiling components
.pdf | 539.34 KB
View
Download
SDS - Gypframe metal products
.pdf | 658.56 KB
View
Download
SDS - Gyptone ceiling tiles planks and boards
.pdf | 593.81 KB
View
Download
Product selector guide
1 datasheet related with the system
1 datasheet related with the system
Selector Guide - Ceilings
.pdf | 1.08 MB
View
Download
CAD details (.dwg)
3 datasheets related with the system
3 datasheets related with the system
ST-326-ZZAA-01-perimeter-and-layout.dwg
.dwg | 97.25 KB
ST-326-ZZAA-02-pb-ceiling-junction.dwg
.dwg | 110.54 KB
ST-326-ZZAA-03-pb-ceiling-junction-change-of-level.dwg
.dwg | 111.10 KB
White Book
3 datasheets related with the system
3 datasheets related with the system
White Book - Finishes
.pdf | 18.28 MB
View
Download
White Book - GypCeiling Grid
.pdf | 4.27 MB
View
Download
White Book - System design principles
.pdf | 3.59 MB
View
Download

If you require previous versions of the documentation related to the products that make up this specification, please click here

Need CAD, BIM, Test Reports and Technical Specifications?

Log in to access CAD .dwg files.

Log in and add a System Specification to a Project to access BIM files, Test Reports, and Technical Specification files.

login

Test Reports

Please add this Specification to a project and go to that Project to access the related Test Reports.

Test report label Test report name
Test report labelSound Absorption Test Report Test report nameDANAK1581
Image
The White Book Specification Selector
Find system specifications that match your needs
Show all specifications
British Gypsum UK

SpecSure

A unique warranty that confirms British Gypsum proprietary systems will perform as specified for the lifetime of the building.

Learn more
Facebook
Twitter
Youtube
LinkedIn
Instagram
Footer left menu
  • About Us
  • Sustainability
  • Building Better Communities
  • Corporate Governance
  • Careers
  • Cookie Policy
  • Privacy Policy
Saint-Gobain

Saint-Gobain Construction Products UK Limited trading as British Gypsum. Registered Office Saint-Gobain House, East Leake, Loughborough, Leicestershire. LE12 6JU.
Company Number 00734396. VAT No: GB 438 3065 50

© Saint-Gobain Construction Products UK Limited 2022. All rights reserved.

  • Product
  • Specification
Compare
Export the list in .csv
Compare