Skip to main content
toggle menu
Home
User account menu
  • Products
  • White Book Specification Selector
  • Log in / Register
Main navigation
  • Inspiration
    Building Better
    • Project Showcase
    Learn more
    Thought Leadership
    • Thought Leadership Articles
    • Thought Leaders
    Learn more
    The Build Better Centre
    Learn more
  • Specification
    White Book Specification Selector
    • White Book Overview
    • Ceilings
    • External Walls
    • Floors
    • Horizontal ShaftWall
    • Internal Partitions & Walls
    • Shaftwall
    • Steel Protection
    • Thistle Plaster Systems
    • Wall Linings
    • BS Specifications
      Display in two columns
      Off
    Learn more
    Our Products
    • Acoustic ceiling systems
    • British Gypsum fixings
    • Gypframe
    • Gyproc jointing products
    • Gyproc plasterboards
    • Thistle plasters
    Learn more
    Resources and Literature
    • All literature
    • Declaration of Performance
    • Product Data Sheets
    • Safety Data Sheets
    • Environmental Product Declarations
    Learn more
    SpecSure® System Warranty
    Learn more
  • Installation
    Our Products
    • Acoustic ceiling systems
    • British Gypsum fixings
    • Gypframe
    • Gyproc jointing products
    • Gyproc plasterboards
    • Thistle plasters
    Learn more
    The Plasterer’s Hub
    • Join the Certified Plasterer Scheme
    • Find a Certified Plasterer
    Learn more
    Installation Guidance and Support
    • Installation Guides
    • Product, project and training support
    Learn more
    Stockist Locator
    Learn more
  • Skills Development
    Upskilling Courses
    • Book a course
    • Training Prospectus
      Display in two columns
      Off
      Background color
      Grey
    • Training Academies
    Learn more
    Students, Apprentices and New Trainees
    • Partnership Colleges
    Learn more
    E-Learning
    • Our Platform and Courses
    Learn more
    CPD Resource
    • Acoustic Design
      Display in two columns
      Off
      Last item
      Désactivé
    • Inhibiting Fire Growth
    • System Integrity
      Display in two columns
      Off
      Last item
      Désactivé
    Learn more
  • Technical Support
    Self Help Tools
    • FAQs
    • Plaster Coverage Calculator
    • Thermal Calculator
    • Design Guidance
    • Resources and Literature
    Learn more
    Technical Consultancy
    • Technical Enquiry Form
    Learn more
    SpecSure® System Warranty
    Learn more
  • Customer Services
    Services
    • Distribution Innovation
    • Track and Trace
    Learn more
Search
Breadcrumb
  1. Home
  2. Specification
  3. White Book Specification Selector
  4. Ceilings
  5. GypCeiling Concealed
  6. C10A212 (EN)
Help menu
Last reviewed:
31.08.2023
Last updated:
13.09.2023
Image
Share
Email Facebook Twitter Linkedin
Print
Bookmark this page
Download
GypCeiling Concealed

C10A212 (EN)

GypCeiling Concealed system using CasoLine Quick-Lock 24/38 tees with a 200mm plenum depth incorporating a Gyptone Point 12 D2 tile.

Read more
Read less
Sound Absorption Coefficient (αw)
0.35
Edge Profile
D2
Sound Absorption Class
D
Add to project
C10A212 (EN)
Share
Email Facebook Twitter Linkedin
Print
Add to project
  • Description
  • Standards
  • Products
  • Details
  • Documents
  • Test Reports
  • Installation
  • Related Case Studies

Standards

Standards Standard types
StandardsBS EN ISO 354,Acoustics - Measurement of sound absorption in a reverberation room. Standard types

Products

Ceiling membrane clip Wall Spring
Ceiling membrane Gyptone Point 12 D2
Clips Cross Lock Connector
Primary framework CasoLine Quick-Lock Grid Main Tee 24/38
Secondary framework CasoLine Quick-Lock Grid Main Tee 24/38
Perimeter framing CasoLine Quick-Lock Grid Wall Angle WA03
Suspension type CasoLine Quick-Lock Grid Hangers
Framework fixing British Gypsum Wafer Head Drywall Screws 13mm
Gypframe MF12 Soffit Cleat
Soffit connection Gypframe MF12 Soffit Cleat

Details

This section should be read in conjunction with the Products list.

  • Framework Fixing: Ends of primary framework are secured to structure at 2400mm centres using an Gypframe MF12 Soffit Cleat fixed to primary framework using wafer head screws and suitably fixed to structure.
  • Installation: The primary framework should be located a maximum of 300mm in from the wall edge and then at centres stated. The cross-lock connector is aligned with the vertical slot in the main tee and clicked in to place; located 600mm in from the wall edge and then at 600mm centres thereafter. The secondary framework is then secured to the Cross Lock Connector via holes in the main tee; legs on the connector bent down, locking tees together. At perimeters ensure the lower edge of the secondary framework is 6mm higher than wall angle.
  • Loadbearing: No
  • Other Requirements: SpecSure® system performance warranty confirms that British Gypsum proprietary systems will perform as specified for the lifetime of the building. The SpecSure® warranty requires that all components are specified in full and constructed in accordance with British Gypsum’s installation guidance. For more details see the British Gypsum website. Always check with the design team before making any changes to the chosen specification, ensuring appropriate substantiation is sought to confirm that the solution still meets all required project performances.
  • Perimeter Framing: Perimeter framing should be suitably fixed to the wall at 300mm centres (maximum 50mm in from a corner). All corners should be mitred.
  • Structural Background: Concrete
  • Maximum Cavity / Plenum (mm): 2010 mm
  • Minimum Cavity / Plenum (mm): 200 mm
  • Primary Framework Centres (mm): 1200 mm
  • Secondary Framework Centres (mm): 600 mm
  • Suspension Type: Suspend ceiling using grid hangers with an appropriate size for the required plenum, secured to primary framework (300mm in from wall) and to soffit cleat via hook. Alternatively, suspension wire (min. 14 swg by others) secured to soffit using fixings recommended by suspended ceiling contractor.
  • Suspension Type Centres (mm): 1200 mm

Documents

Select all
Technical Specification
1 datasheet related with the system
1 datasheet related with the system
British-Gypsum-TS-C10A212-EN.pdf
Technical Specification
.pdf | 111.99 KB
Test reports
1 datasheet related with the system
1 datasheet related with the system
BTC_21785A.pdf
Test reports
.pdf | 2.29 MB
Brochures & Leaflets
1 datasheet related with the system
1 datasheet related with the system
Ceilings Brochure
Brochures & Leaflets
.pdf | 16.72 MB
View
Download
Declaration Of Performance (DoP)
8 datasheets related with the system
8 datasheets related with the system
DoP - 165-EN-en-22550-1 - Quick-Lock Cross Lock Connector
Declaration Of Performance (DoP)
.pdf | 863.49 KB
View
Download
DoP - 185-EN-en-22559-1 - Quick-Lock Suspenders
Declaration Of Performance (DoP)
.pdf | 669.06 KB
View
Download
DoP - 190-EN-en-22556-1 - Quick-Lock Connectors
Declaration Of Performance (DoP)
.pdf | 847.37 KB
View
Download
DoP - CEILING202 - CasoLine Quick-Lock Grid T24
Declaration Of Performance (DoP)
.pdf | 149.86 KB
View
Download
DoP - CEILING203 - CasoLine Quick-Lock Grid wall angles
Declaration Of Performance (DoP)
.pdf | 148.75 KB
View
Download
DoP - FIX100 - British Gypsum Screws
Declaration Of Performance (DoP)
.pdf | 121.11 KB
View
Download
DoP - FIX100 UK - British Gypsum Screws
Declaration Of Performance (DoP)
.pdf | 99.67 KB
View
Download
DoP - GYP14190 - Gyptone Tiles
Declaration Of Performance (DoP)
.pdf | 116.74 KB
View
Download
Product Data Sheet (PDS)
7 datasheets related with the system
7 datasheets related with the system
PDS - CasoLine Quick-Lock Grid Hangers
Product Data Sheet (PDS)
.pdf | 148.66 KB
View
Download
PDS - CasoLine Quick-Lock Grid Main Tee 24/38
Product Data Sheet (PDS)
.pdf | 211.40 KB
View
Download
PDS - CasoLine Quick-Lock Grid Wall Angle WA03
Product Data Sheet (PDS)
.pdf | 154.06 KB
View
Download
PDS - Cross Lock Connector
Product Data Sheet (PDS)
.pdf | 139.99 KB
View
Download
PDS - Gypframe MF12 Soffit Cleat
Product Data Sheet (PDS)
.pdf | 207.34 KB
View
Download
PDS - Gyptone Point 12 D2
Product Data Sheet (PDS)
.pdf | 187.66 KB
View
Download
PDS - Wafer Head Drywall Screws 13mm
Product Data Sheet (PDS)
.pdf | 173.59 KB
View
Download
Safety Data Sheet (SDS)
4 datasheets related with the system
4 datasheets related with the system
SDS - British Gypsum fixings
Safety Data Sheet (SDS)
.pdf | 517.14 KB
View
Download
SDS - CasoLine Quick-Lock Grid ceiling components
Safety Data Sheet (SDS)
.pdf | 539.34 KB
View
Download
SDS - Gypframe metal products
Safety Data Sheet (SDS)
.pdf | 658.56 KB
View
Download
SDS - Gyptone ceiling tiles planks and boards
Safety Data Sheet (SDS)
.pdf | 593.81 KB
View
Download
Product selector guide
1 datasheet related with the system
1 datasheet related with the system
Selector Guide - Ceilings
Product selector guide
.pdf | 877.68 KB
View
Download
CAD details (.dwg)
1 datasheet related with the system
1 datasheet related with the system
ST-328-ZZD2-01-perimeter-and-layout.dwg
CAD details (.dwg)
.dwg | 111.71 KB
CAD details (PDF)
1 datasheet related with the system
1 datasheet related with the system
ST-328-ZZD2-01-perimeter-and-layout.pdf
CAD details (PDF)
.pdf | 225.44 KB
View
Download
White Book
3 datasheets related with the system
3 datasheets related with the system
White Book - Finishes
White Book
.pdf | 18.29 MB
View
Download
White Book - GypCeiling Concealed
White Book
.pdf | 1.08 MB
View
Download
White Book - System design principles
White Book
.pdf | 3.59 MB
View
Download

Our website ALWAYS carries the latest and most up to date version of all of these documents, but on occasion there is a need for previous versions. If you do require a previous version of documents related to the products that make up this specification click here

Need CAD, BIM, Test Reports and Technical Specifications?

Log in to access CAD .dwg files.

Log in and add a System Specification to a Project to access BIM files, Test Reports, and Technical Specification files.

login

Test Reports

Please add this Specification to a project and go to that Project to access the related Test Reports.

Test report label Test report name
Test report labelSound Absorption Test Report Test report nameBTC 21785A
Image
The White Book Specification Selector
Find system specifications that match your needs
Show all specifications
British Gypsum UK

SpecSure

A unique warranty that confirms British Gypsum proprietary systems will perform as specified for the lifetime of the building.

Learn more
Facebook
Twitter
Youtube
LinkedIn
Instagram
Footer left menu
  • About Us
  • Sustainability
  • Building Better Communities
  • Corporate Governance
  • Careers
  • Cookie Policy
  • Privacy Policy
Saint-Gobain

Saint-Gobain Construction Products UK Limited trading as British Gypsum. Registered Office Saint-Gobain House, East Leake, Loughborough, Leicestershire. LE12 6JU.
Company Number 00734396. VAT No: GB 438 3065 50

© Saint-Gobain Construction Products UK Limited 2022. All rights reserved.

  • Product
  • Specification
Compare
Export the list in .csv
Compare