Menu
Gyproc FireLine

Gyproc FireLine

Gypsum plasterboard with fire resistant additives with pink paper lining for easy recognition.

Gypsum plasterboard with glass fibre and additional additives to increase the fire protection characteristics with pink paper lining for easy recognition. The additional fire protection properties above standard board products enable the plasterboard to be used in partition, ceiling and steel encasement systems where more stringent fire performance is required such as in domestic separating walls, corridors, garages and steel encasement. 

  • Pink face paper
  • Brown reverse side paper
  • Available in tapered and square edge
  • Complies with EN 520 – Type F Thermal
  • Conductivity 0.24W/mK

12.5mm board

Order Code Width (mm) Length (mm) Weight (kg/m²) Edge Type R value
01909/8 900 1800 9.8 T/E 0.05
01843/5 900 1800 9.8 S/E 0.05
01886/2 1200 2400 9.8 T/E 0.05
01919/7 1200 2400 9.8 S/E 0.05
01877/0 1200 2700 9.8 T/E 0.05
27472/5 1200 3000 9.8 T/E 0.05

15mm board

Order Code Width (mm) Length (mm) Weight (kg/m²) Edge Type R value
01613/4 900 1800 11.7 T/E 0.06
01726/1 1200 2400 11.7 T/E 0.06
01189/4 1200 2400 11.7 S/E 0.06
01198/6 1200 2700 11.7 T/E 0.06
01572/4 1200 3000 11.7 T/E 0.06

How do you fire protect structural steel sections?

We offer the FireCase system or the GypLyner ENCASE system to form an encasement around the beam or column.

How much space is required to encase steel sections?

With our FireCase frameless encasement system it could be only the Glasroc F FIRECASE board width itself (e.g. minimum 15mm). Our GypLyner ENCASE system requires more space due to the metal framework.

How do you provide a 30 or 60 minute fire-rated horizontal membrane?

For our range of systems fixed to timber joist / bottom chord of trusses to meet 30 or 60 minute fire resistance to BS 476: Part 22 please refer to WHITE BOOK Chapter 06 Section 06 Page 11 for more details.

How do you upgrade the fire and/or acoustic performance of a timber floor from below?

We offer a wide range of ceiling systems for this purpose including GypLyner UNIVERSAL and CasoLine MF.

What is the fire resistance performance of Gyproc plasterboard? Will I achieve 60 minutes fire resistance from 12.5mm Gyproc FireLine? What fire rating does a Board give? What fire rating does Fireline Board offer?

Fire resistance performance is based on complete systems such as a partition, wall, ceiling membrane or floor, therefore plasterboard cannot be considered on their own in terms of fire resistance.